You are currently reviewing an older revision of this page.
Normally, any loose component changes to field because it does not need to work in shop. However, you can control this separately for pipes and fittings by modifying below settings from style.cfg
1. Open the project style.cfg file
2. Search IE_LoosePipeToField in this file
3. Change the fitting settings to IE_LooseFittingToField = 1. This will enable any loose field fitting to appear in field material under BOM
4. Save the changes and Generate the Iso again
5. Notice below image the elbow comes under field material