<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>To Assign Separate levels for Model Centerline &amp; Insulation Based on Service</title><link>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/21764/to-assign-separate-levels-for-model-centerline-insulation-based-on-service</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>To Assign Separate levels for Model Centerline &amp; Insulation Based on Service</title><link>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/21764/to-assign-separate-levels-for-model-centerline-insulation-based-on-service</link><pubDate>Fri, 18 Nov 2016 12:55:27 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:b74d9367-6b6d-4f0c-803a-27dcb2484279</guid><dc:creator>Rahul Kumar</dc:creator><comments>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/21764/to-assign-separate-levels-for-model-centerline-insulation-based-on-service#comments</comments><description>Current Revision posted to OpenPlant | AutoPLANT Wiki by Rahul Kumar on 11/18/2016 12:55:27 PM&lt;br /&gt;
&lt;h1&gt;&lt;b&gt;&lt;img src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" height="60" alt=" " /&gt;&lt;/b&gt;&lt;/h1&gt;
&lt;div class="content-scrollable-wrapper"&gt;
&lt;table border="0" style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Applies To&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenPlant Modeler&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.11.09.XXX (SS5) | 08.11.11.XX (SS6)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Windows 7/8.1/10 (64 bit)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Settings/Attributes&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;-&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Rahul Kumar, Bentley Product Advantage Group&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;To set Pipeline colors based on service and different level as per various template groups such as Piping, Centerline &amp;amp; Insulation. Below steps will aid user to achieve the desired settings.&lt;/p&gt;
&lt;h3&gt;Background&lt;/h3&gt;
&lt;p&gt;OpenPlant component symbology is managed in the typical Microstation fashion. It is controlled through a combination of Named Expressions (used to read attributes and assign the Element Templates accordingly) and Element Templates (where symbology is defined for the elements identified by the Named Expression).&lt;/p&gt;
&lt;h3&gt;Steps to Accomplish&lt;/h3&gt;
&lt;ol&gt;
&lt;li&gt;All of component symbology settings are usually set in OPmodeler.dgnlib file, located in WorkSpace\Projects\%project_name%\DataSet\Dgnlibs folder. Navigate to mentioned path to open the file.&lt;/li&gt;
&lt;li&gt;In menu select Element -&amp;gt; &lt;strong&gt;Element Templates.&lt;/strong&gt;&lt;/li&gt;
&lt;li&gt;Browse to OpenPlant -&amp;gt; &lt;strong&gt;Piping&lt;/strong&gt; section, see what templates are already available. If required create new services:&lt;/li&gt;
&lt;li&gt;Set symbology as per requirement. See below has been set for few existing Services.&lt;br /&gt;&lt;br /&gt;For Model:&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/6_2D00_3_2D00_2015-3_2D00_57_2D00_00-PM.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-43/6_2D00_3_2D00_2015-3_2D00_57_2D00_00-PM.png" width="468" height="218" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;For Centerline:&amp;nbsp;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/5287.2.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-43/5287.2.png" width="468" height="230" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;For Insulation:&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/7652.3.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-43/7652.3.png" width="471" height="217" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;In menu open Utilities -&amp;gt; Named Expressions. Here for Pipelines, it is required update 3 expressions:&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;OP_SYMBOLOGY_PIPING:&lt;/strong&gt;&lt;br /&gt; &lt;code&gt;&amp;quot;BY_LEVEL_AND_TEMPLATE:&amp;quot; &amp;amp; PIPELINE.NAME &amp;amp; &amp;quot;:OpenPlant\Piping\&amp;quot; &amp;amp; PIPELINE.SERVICE_NAME &amp;amp; &amp;quot;:Model&amp;quot;&lt;/code&gt;&lt;br /&gt; &lt;br /&gt; &lt;strong&gt;OP_SYMBOLOGY_PIPING_CENTERLINE:&lt;/strong&gt;&lt;br /&gt; &lt;code&gt;&amp;quot;BY_LEVEL_AND_TEMPLATE:&amp;quot; &amp;amp; PIPELINE.NAME &amp;amp; &amp;ldquo;_CL&amp;rdquo; &amp;amp; &amp;quot;:OpenPlant\Piping\&amp;quot; &amp;amp; PIPELINE.SERVICE_NAME &amp;amp; &amp;quot;:Centerline&amp;quot;&lt;/code&gt;&lt;br /&gt; &lt;br /&gt; &lt;strong&gt;OP_SYMBOLOGY_PIPING_INSULATION:&lt;/strong&gt;&lt;br /&gt; &lt;code&gt;&amp;quot;BY_LEVEL_AND_TEMPLATE:&amp;quot; &amp;amp; PIPELINE.NAME &amp;amp; &amp;ldquo;_Ins&amp;rdquo; &amp;amp; &amp;quot;:OpenPlant\Piping\&amp;quot; &amp;amp; PIPELINE.SERVICE_NAME &amp;amp; &amp;quot;:Insulation&amp;quot;&lt;/code&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Save Expression and close the dialog box.&lt;/li&gt;
&lt;li&gt;Save and close the DGNLIB file.&lt;/li&gt;
&lt;li&gt;Launch OpenPlant Modeler and verify results with working DGN file.&amp;nbsp;&lt;br /&gt;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/2860.4.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2860.4.png" width="536" height="357" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;h3&gt;See Also&lt;/h3&gt;
&lt;p&gt;&lt;a href="http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/4870.named-expressions-managing-component-symbology-in-openplant-modeler"&gt;communities.bentley.com/.../4870.named-expressions-managing-component-symbology-in-openplant-modeler&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Comments or Corrections?&lt;/h3&gt;
&lt;p&gt;Bentley&amp;#39;s Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;
&lt;/div&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: OpenPlant Modeler, Named Expressions, 08.11.09.XXX&lt;/div&gt;
</description></item><item><title>To Assign Separate levels for Model Centerline &amp; Insulation Based on Service</title><link>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/21764/to-assign-separate-levels-for-model-centerline-insulation-based-on-service/revision/2</link><pubDate>Fri, 18 Nov 2016 08:54:12 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:b74d9367-6b6d-4f0c-803a-27dcb2484279</guid><dc:creator>Rahul Kumar</dc:creator><comments>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/21764/to-assign-separate-levels-for-model-centerline-insulation-based-on-service#comments</comments><description>Revision 2 posted to OpenPlant | AutoPLANT Wiki by Rahul Kumar on 11/18/2016 8:54:12 AM&lt;br /&gt;
&lt;h1&gt;&lt;b&gt;&lt;img src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" height="60" alt=" " /&gt;&lt;/b&gt;&lt;/h1&gt;
&lt;div class="content-scrollable-wrapper"&gt;
&lt;table border="0" style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Applies To&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenPlant Modeler&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.11.09.XXX (SS5) | 08.11.11.XX (SS6)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Windows 7/8.1/10 (64 bit)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Settings/Attributes&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;-&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Rahul Kumar, Bentley Product Advantage Group&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;To set Pipeline colors based on service and different level as per various template groups such as Piping, Centerline &amp;amp; Insulation. Below steps will aid user to achieve the desired settings.&lt;/p&gt;
&lt;h3&gt;Background&lt;/h3&gt;
&lt;p&gt;OpenPlant component symbology is managed in the typical Microstation fashion. It is controlled through a combination of Named Expressions (used to read attributes and assign the Element Templates accordingly) and Element Templates (where symbology is defined for the elements identified by the Named Expression).&lt;/p&gt;
&lt;h3&gt;Steps to Accomplish&lt;/h3&gt;
&lt;ol&gt;
&lt;li&gt;All of component symbology settings are usually set in OPmodeler.dgnlib file, located in WorkSpace\Projects\%project_name%\DataSet\Dgnlibs folder. Navigate to mentioned path to open the file.&lt;/li&gt;
&lt;li&gt;In menu select Element -&amp;gt; Element Templates;&lt;/li&gt;
&lt;li&gt;Browse to OpenPlant -&amp;gt; Piping section, see what templates are already available. If required create new services:&lt;/li&gt;
&lt;li&gt;Set symbology as per requirement. See below has been set for few existing Services.&lt;br /&gt;&lt;br /&gt;For Model:&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/6_2D00_3_2D00_2015-3_2D00_57_2D00_00-PM.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-43/6_2D00_3_2D00_2015-3_2D00_57_2D00_00-PM.png" width="468" height="218" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;For Centerline:&amp;nbsp;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/5287.2.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-43/5287.2.png" width="468" height="230" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;For Insulation:&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/7652.3.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-43/7652.3.png" width="471" height="217" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;In menu open Utilities -&amp;gt; Named Expressions. Here for Pipelines, it is required update 3 expressions:&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;OP_SYMBOLOGY_PIPING:&lt;/strong&gt;&lt;br /&gt; &lt;code&gt;&amp;quot;BY_LEVEL_AND_TEMPLATE:&amp;quot; &amp;amp; PIPELINE.NAME &amp;amp; &amp;quot;:OpenPlant\Piping\&amp;quot; &amp;amp; PIPELINE.SERVICE_NAME &amp;amp; &amp;quot;:Model&amp;quot;&lt;/code&gt;&lt;br /&gt; &lt;br /&gt; &lt;strong&gt;OP_SYMBOLOGY_PIPING_CENTERLINE:&lt;/strong&gt;&lt;br /&gt; &lt;code&gt;&amp;quot;BY_LEVEL_AND_TEMPLATE:&amp;quot; &amp;amp; PIPELINE.NAME &amp;amp; &amp;ldquo;_CL&amp;rdquo; &amp;amp; &amp;quot;:OpenPlant\Piping\&amp;quot; &amp;amp; PIPELINE.SERVICE_NAME &amp;amp; &amp;quot;:Centerline&amp;quot;&lt;/code&gt;&lt;br /&gt; &lt;br /&gt; &lt;strong&gt;OP_SYMBOLOGY_PIPING_INSULATION:&lt;/strong&gt;&lt;br /&gt; &lt;code&gt;&amp;quot;BY_LEVEL_AND_TEMPLATE:&amp;quot; &amp;amp; PIPELINE.NAME &amp;amp; &amp;ldquo;_Ins&amp;rdquo; &amp;amp; &amp;quot;:OpenPlant\Piping\&amp;quot; &amp;amp; PIPELINE.SERVICE_NAME &amp;amp; &amp;quot;:Insulation&amp;quot;&lt;/code&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Save Expression and close the dialog box.&lt;/li&gt;
&lt;li&gt;Save and close the DGNLIB file.&lt;/li&gt;
&lt;li&gt;Launch OPM and verify results with working DGN file.&amp;nbsp;&lt;br /&gt;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/2860.4.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2860.4.png" width="536" height="357" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;h3&gt;See Also&lt;/h3&gt;
&lt;p&gt;&lt;a href="http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/4870.named-expressions-managing-component-symbology-in-openplant-modeler"&gt;communities.bentley.com/.../4870.named-expressions-managing-component-symbology-in-openplant-modeler&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Comments or Corrections?&lt;/h3&gt;
&lt;p&gt;Bentley&amp;#39;s Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;
&lt;/div&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: OpenPlant Modeler, Named Expressions, 08.11.09.XXX&lt;/div&gt;
</description></item><item><title>To Assign Separate levels for Model Centerline &amp; Insulation Based on Service</title><link>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/21764/to-assign-separate-levels-for-model-centerline-insulation-based-on-service/revision/1</link><pubDate>Wed, 03 Jun 2015 15:28:51 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:b74d9367-6b6d-4f0c-803a-27dcb2484279</guid><dc:creator>Rahul Kumar</dc:creator><comments>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/21764/to-assign-separate-levels-for-model-centerline-insulation-based-on-service#comments</comments><description>Revision 1 posted to OpenPlant | AutoPLANT Wiki by Rahul Kumar on 6/3/2015 3:28:51 PM&lt;br /&gt;
&lt;h1&gt;&lt;b&gt;&lt;img src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" height="60" alt=" " /&gt;&lt;/b&gt;&lt;/h1&gt;
&lt;div class="content-scrollable-wrapper"&gt;
&lt;table border="0" style="border:0px solid #dce5f0;width:500px;background-color:#dce5f0;"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;strong&gt;Applies To&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenPlant Modeler&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.11.09.XXX&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Windows 7 64 bit &amp;amp; Others&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Settings/Attributes&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;-&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;/td&gt;
&lt;td&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Rahul Kumar, Bentley Technical Support&amp;nbsp;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;To set Pipeline colors based on service and different level as per various template groups such as Piping, Centerline &amp;amp; Insulation. Below steps will aid user to achieve the desired settings.&lt;/p&gt;
&lt;h1&gt;Background&lt;/h1&gt;
&lt;p&gt;OpenPlant component symbology is managed in the typical Microstation fashion. It is controlled through a combination of Named Expressions (used to read attributes and assign the Element Templates accordingly) and Element Templates (where symbology is defined for the elements identified by the Named Expression).&lt;/p&gt;
&lt;h1&gt;Steps to Accomplish&lt;/h1&gt;
&lt;ol&gt;
&lt;li&gt;All of component symbology settings are usually set in OPmodeler.dgnlib file, located in WorkSpace\Projects\%project_name%\DataSet\Dgnlibs folder. Navigate to mentioned path to open the file.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;In menu select Element -&amp;gt; Element Templates;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Browse to OpenPlant -&amp;gt; Piping section, see what templates are already available. If required create new services:&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Set symbology as per requirement. See below has been set for few existing Services.&lt;br /&gt;&lt;br /&gt;For Model:&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/6_2D00_3_2D00_2015-3_2D00_57_2D00_00-PM.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-43/6_2D00_3_2D00_2015-3_2D00_57_2D00_00-PM.png" width="468" height="218" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;For Centerline:&amp;nbsp;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/5287.2.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-43/5287.2.png" width="468" height="230" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;For Insulation:&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/7652.3.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-43/7652.3.png" width="471" height="217" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;In menu open Utilities -&amp;gt; Named Expressions. Here for Pipelines, it is required update 3 expressions:&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;OP_SYMBOLOGY_PIPING:&lt;/strong&gt;&lt;br /&gt; &lt;code&gt;&amp;quot;BY_LEVEL_AND_TEMPLATE:&amp;quot; &amp;amp; PIPELINE.NAME &amp;amp; &amp;quot;:OpenPlant\Piping\&amp;quot; &amp;amp; PIPELINE.SERVICE_NAME &amp;amp; &amp;quot;:Model&amp;quot;&lt;/code&gt;&lt;br /&gt; &lt;br /&gt; &lt;strong&gt;OP_SYMBOLOGY_PIPING_CENTERLINE:&lt;/strong&gt;&lt;br /&gt; &lt;code&gt;&amp;quot;BY_LEVEL_AND_TEMPLATE:&amp;quot; &amp;amp; PIPELINE.NAME &amp;amp; &amp;ldquo;_CL&amp;rdquo; &amp;amp; &amp;quot;:OpenPlant\Piping\&amp;quot; &amp;amp; PIPELINE.SERVICE_NAME &amp;amp; &amp;quot;:Centerline&amp;quot;&lt;/code&gt;&lt;br /&gt; &lt;br /&gt; &lt;strong&gt;OP_SYMBOLOGY_PIPING_INSULATION:&lt;/strong&gt;&lt;br /&gt; &lt;code&gt;&amp;quot;BY_LEVEL_AND_TEMPLATE:&amp;quot; &amp;amp; PIPELINE.NAME &amp;amp; &amp;ldquo;_Ins&amp;rdquo; &amp;amp; &amp;quot;:OpenPlant\Piping\&amp;quot; &amp;amp; PIPELINE.SERVICE_NAME &amp;amp; &amp;quot;:Insulation&amp;quot;&lt;/code&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Save Expression and close the dialog box.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Save and close the DGNLIB file.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Launch OPM and verify results with working DGN file.&amp;nbsp;&lt;br /&gt;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/2860.4.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2860.4.png" width="536" height="357" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;a class="ExistingPageLink" href="/products/plant/design___engineering/w/plant_design_and_engineering__wiki/4870.named-expressions-managing-component-symbology-in-openplant-modeler" title="Click to view the page titled: Named Expressions: Managing Component Symbology in OpenPlant Modeler"&gt;Named Expressions: Managing Component Symbology in OpenPlant Modeler&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;Bentley&amp;#39;s Technical Support Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;
&lt;/div&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: OpenPlant Modeler, Named Expressions, 08.11.09.XXX&lt;/div&gt;
</description></item></channel></rss>