AutoPLANT | OpenPlant | PlantWise Wiki Description for Bolts, Gaskets not Getting Inside Isometric BOM & Showing as "NODESC"
    • Sign in
    • -AutoPLANT | Bentley Raceway and Cable Management | OpenPlant | PlantWise Wiki
      • -OpenPlant
        • +CONNECT Services - OpenPlant
        • +Example Configuration - CONNECT Edition
        • +Installations - OpenPlant CONNECT Edition Applications
        • +OpenPlant Download Links & Videos
        • OpenPlant Product Compatibility
        • +OpenPlant Modeler CONNECT
        • +OpenPlant PID CONNECT
        • +OpenPlant Isometrics Manager CONNECT
        • +OpenPlant Orthographics Manager CONNECT
        • +OpenPlant Support Engineering CONNECT
        • +OpenPlant Project Administrator CONNECT
        • +OpenPlant CONNECT Edition-PlantSight Integration
        • +OpenPlant Modeler v8i
        • -OpenPlant Isometrics Manager v8i
          • -OpenPlant Isometrics Manager for OpenPlant
            • Installation/Upgradation Steps for OpenPlant Isometrics Manager
            • -Errors, Logs, Messages, Crashes - OpenPlant Isometrics Manager
              • Description for Bolts, Gaskets not Getting Inside Isometric BOM & Showing as "NODESC"
              • Displays Error[5]-DWG creation failed While Generating Isometric Output as DWG Format
              • Error Copying Document to the Client While Loading I-model
              • Error: = 1603 While Installation of OpenPlant Isometrics Manager
              • Error "Empty Path Name is not legal" Pops Up at Startup
              • Error Distance Between Gasket [Gasket][GUID No] & Adjoin Components could be more than 1.5
              • Error Loading I-model: Unable to Validate Expression Properties
              • Error on Loading I-model from Managed Workspace in OpenPlant Isometrics Manager
              • Error While Reading ECSchema 'OpenPlant_3D.01.04
              • Error[0]:SYS mismatch CP/CP count: component ID = 1 in OpenPlant Isometrics Manager
              • Error [5] Unable to locate addon (ID=XXX) to component
              • Error:[5] Detail Sketch Not found in cell libraries
              • Error: i-model master unit 'Feet' is not matching with 'MILLIMETERS', specified as PROJ_MASTER_UNIT in OPModeler_MMetric project pcf. You might have selected wrong workspace project or i-model.
              • Error: An internal error occurred.Could not start responsive Microstation server.
              • Error: Could not start IMODEL Engine Process in 60 seconds.
              • Error: Exception has been thrown by the target of an invocation. Argument 'ecProperty for msi_TransactionID' cannot be a null value
              • ERROR: Weld[WELD]123xxxxxxxxGUID is not connected to Pipe
              • Fixing Sheet No. Issues in OpenPlant Isometrics Manager
              • OpenPlant Isometrics Manager Bill of Material Components sort by lines.
              • Scaler, Symbols or Item code are missing for TAP_CONNECTION error message when Branch Connected Through Stub-In Tapport
              • Unable to Launch OpenPlant Isometrics Manager
              • Unable to Load i-model in OpenPlant Isometrics Manager
              • Error[0]: no DEF entry for Scalar Type DUMMYPIPE in Openplant Isometrics Manager
            • +Open/Save - OpenPlant Isometrics Manager
            • +Processing - OpenPlant Isometrics Manager
            • +Settings/Attributes - OpenPlant Isometrics Manager
          • +OpenPlant Isometrics Manager for AutoPLANT
          • +Release Notes - OpenPlant Isometrics Manager
          • OpenPlant Isometrics Manager [FAQ]
        • +OpenPlant Project Administrator v8i
        • +OpenPlant PID v8i
        • +OpenPlant Orthographics Manager v8i
        • +OpenPlant Support Engineering v8i
        • +OpenPlant ModelServer v8i
        • +OpenPlant Reporting v8i
        • How to Connect with Bentley Technical Support Team using Microsoft Teams
        • How to Connect with Bentley Technical Support Team using Microsoft Teams via Browser
      • +Bentley AutoPLANT
      • +Bentley Navigator
      • +Bentley PlantSpace
      • +Plant Project Tools
      • +Bentley Raceway and Cable Management
      • i-model Composition Service for S3D
      • Working from home with OpenPlant
      • Working from home with Bentley Raceway and Cable Management
      • Working from home with AutoPLANT Modeler
    • How to Associate the Specification Based on Service in OpenPlant Modeler Connect

     
     Questions about this article, topic, or product? Click here. 

    Description for Bolts, Gaskets not Getting Inside Isometric BOM & Showing as "NODESC"

    Applies To 
    Product(s):  OpenPlant Isometrics Manager
    Version(s):  08.11.09.574 (SS5)
    Environment:  Windows 7/8.1/10 (64 bit)
    Area:  Settings/Attributes
    Subarea:   BOM Description
    Original Author:  Abhijit Bute, Bentley Product Advantage Group

    Problem Description

    During isometric generation of OpenPlant Isometrics Manager, Description for gasket and bolts are not getting updated in isometric.It shows as 'NODESC'. See image below.

               

    See below case for both OpenPlant Modeler-OpenPlant Isometrics Manager & AutoPLANT Modeler-OpenPlant Isometrics Manager. 

    OpenPlant Modeler-OpenPlant Isometrics Manager

    Steps to Resolve

    1. Reason for showing NO DESC in isometrics BOM is due to empty description data present in spec. 
    2. Open Spec through MS Access .MDB file. 
      Note - A fundamental use of MS Access MDB file handling should require.

    3. Navigate to GASKET table. 
    4. Check for DESCRIPTION field. See image below. 



    5. In OpenPlant Modeler, it displays under Modify Component/Element Information dialog. See image below. 



    6. To resolve the matter, user should run spec validation report and update the revised DESCRIPTION to appear correctly in Isometrics BOM. 
    7. Click here to check similar wiki article on Spec Validation.
    8. Ensure the correct validation by repeating step 5 mentioned above. See image below with DESCRIPTION field. 



    9. Generate Isometrics and verify results. It will fix NO DESC issue. 

    AutoPLANT Modeler-OpenPlant Isometrics Manager

    Steps to Resolve

    1. Open Bentley Class Editor. 
    2. Open "OpenPlant_3D.01.06 schema". See Image below. 



      Note - Navigate to working project path as shown below.
      (C:\ProgramData\Bentley\Plant V8i\Bentley Plant V8i Projects\SAMPLE_IMPERIAL\Config\OpenPlant\schemas)

    3. Right click on "OpenPlant_3D.01.06 schema" &S click on supplement Schema option. 



    4. Using "Add" button, select Supplemental schema "OpenPlant_3D_Supplemental_Isometrics_Isoextractor.01.06 schema" and click on "Open". See image below. 



    5. (Optional If dialog appears) Click on "Open" for allowing to select Missing reference schema folder. See image below on how to navigate the correct folder path. User may cancel to load other available reference schema. 


      Note - Path to check - (C:\ProgramData\Bentley\Plant V8i\Bentley Plant V8i Projects\SAMPLE_IMPERIAL\Config\OpenPlant\schemas)

    6. Search/Navigate to GASKET class as shown in below image.



    7. Highlight Gasket on the left and go to the "Properties" tab on the right and highlight DESCRIPTION property.
    8. Click on Add/Remove Custom attributes.See image below.



    9. Find the "AutoPLANT_PDW_Property_Map", highlight it and pull it down to add it in. Click "OK".



    10. Under the "AutoPLANT 3D" custom attribute, add LONG_DESC in the Property Name field. See image below.



    11. Navigate to BOLT class.
    12. Repeat Step 9 & 10 under Bolt Property tab.
    13. Save and close Schema.
    14. Restart AutoPLANT Modeler and review the result.



    15. Also perform the above steps in the schemas for other projects
      C:\Program Files (x86)\Bentley\Plant V8i\Config\Metric\OpenPlant\schemas
      C:\Program Files (x86)\Bentley\Plant V8i\Config\Mmetric\OpenPlant\schemas
      C:\Program Files (x86)\Bentley\Plant V8i\Config\Imperial\OpenPlant\schemas

    16. This ensures that new created project also has the descriptions. 

    Still a Problem?

    If above problem still persist, then please create a Service Request and contact the Bentley Product Advantage group. Please include a list of all relevant details to get in depth analysis for a solution or workaround. 

    See Also

    http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/20662.errors-logs-messages-crashes-openplant-isometrics-manager

    Comments or Corrections?

    Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!

    • Bill of Materials
    • auotplant
    • OPIM
    • BOM
    • 08.11.09.XXX
    • NO DESC
    • 08.11.09.458
    • OpenPlant Isometrics Manager
    • APM-OPIM
    • Share
    • History
    • More
    • Cancel
    • Abhijit Bute Created by Bentley Colleague Abhijit Bute
    • When: Tue, Jun 9 2015 6:30 AM
    • Kestutis Mitkus Last revision by Bentley Colleague Kestutis Mitkus
    • When: Wed, Dec 12 2018 9:40 AM
    • Revisions: 23
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2021 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies