Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
  • Welcome
  • Products
  • Support
  • About
  • More
  • Cancel
AutoPLANT | OpenPlant | PlantWise
  • Product Communities
  • More
AutoPLANT | OpenPlant | PlantWise
AutoPLANT | OpenPlant | PlantWise Wiki Scaler, Symbols or Item code are missing for TAP_CONNECTION error message when Branch Connected Through Stub-In Tapport
    • Sign in
    • -AutoPLANT | Bentley Raceway and Cable Management | OpenPlant | PlantWise Wiki
      • -OpenPlant
        • +CONNECT Services - OpenPlant
        • +Example Configuration - CONNECT Edition
        • +Installations - OpenPlant CONNECT Edition Applications
        • +OpenPlant Download Links & Videos
        • OpenPlant Product Compatibility
        • +OpenPlant Modeler CONNECT
        • +OpenPlant PID CONNECT
        • +OpenPlant Isometrics Manager CONNECT
        • +OpenPlant Orthographics Manager CONNECT
        • +OpenPlant Support Engineering CONNECT
        • +OpenPlant Project Administrator CONNECT
        • +OpenPlant CONNECT Edition-PlantSight Integration
        • +OpenPlant Modeler v8i
        • -OpenPlant Isometrics Manager v8i
          • -OpenPlant Isometrics Manager for OpenPlant
            • Installation/Upgradation Steps for OpenPlant Isometrics Manager
            • -Errors, Logs, Messages, Crashes - OpenPlant Isometrics Manager
              • Description for Bolts, Gaskets not Getting Inside Isometric BOM & Showing as "NODESC"
              • Displays Error[5]-DWG creation failed While Generating Isometric Output as DWG Format
              • Error Copying Document to the Client While Loading I-model
              • Error: = 1603 While Installation of OpenPlant Isometrics Manager
              • Error "Empty Path Name is not legal" Pops Up at Startup
              • Error Distance Between Gasket [Gasket][GUID No] & Adjoin Components could be more than 1.5
              • Error Loading I-model: Unable to Validate Expression Properties
              • Error on Loading I-model from Managed Workspace in OpenPlant Isometrics Manager
              • Error While Reading ECSchema 'OpenPlant_3D.01.04
              • Error[0]:SYS mismatch CP/CP count: component ID = 1 in OpenPlant Isometrics Manager
              • Error [5] Unable to locate addon (ID=XXX) to component
              • Error:[5] Detail Sketch Not found in cell libraries
              • Error: i-model master unit 'Feet' is not matching with 'MILLIMETERS', specified as PROJ_MASTER_UNIT in OPModeler_MMetric project pcf. You might have selected wrong workspace project or i-model.
              • Error: An internal error occurred.Could not start responsive Microstation server.
              • Error: Could not start IMODEL Engine Process in 60 seconds.
              • Error: Exception has been thrown by the target of an invocation. Argument 'ecProperty for msi_TransactionID' cannot be a null value
              • ERROR: Weld[WELD]123xxxxxxxxGUID is not connected to Pipe
              • Fixing Sheet No. Issues in OpenPlant Isometrics Manager
              • OpenPlant Isometrics Manager Bill of Material Components sort by lines.
              • Scaler, Symbols or Item code are missing for TAP_CONNECTION error message when Branch Connected Through Stub-In Tapport
              • Unable to Launch OpenPlant Isometrics Manager
              • Unable to Load i-model in OpenPlant Isometrics Manager
              • Error[0]: no DEF entry for Scalar Type DUMMYPIPE in Openplant Isometrics Manager
            • +Open/Save - OpenPlant Isometrics Manager
            • +Processing - OpenPlant Isometrics Manager
            • +Settings/Attributes - OpenPlant Isometrics Manager
          • +OpenPlant Isometrics Manager for AutoPLANT
          • +Release Notes - OpenPlant Isometrics Manager
          • OpenPlant Isometrics Manager [FAQ]
        • +OpenPlant Project Administrator v8i
        • +OpenPlant PID v8i
        • +OpenPlant Orthographics Manager v8i
        • +OpenPlant Support Engineering v8i
        • +OpenPlant ModelServer v8i
        • +OpenPlant Reporting v8i
        • How to Connect with Bentley Technical Support Team using Microsoft Teams
        • How to Connect with Bentley Technical Support Team using Microsoft Teams via Browser
      • +Bentley AutoPLANT
      • +Bentley Navigator
      • +Bentley PlantSpace
      • +Plant Project Tools
      • +Bentley Raceway and Cable Management
      • i-model Composition Service for S3D
      • Working from home with OpenPlant
      • Working from home with Bentley Raceway and Cable Management
      • Working from home with AutoPLANT Modeler
    • How to Associate the Specification Based on Service in OpenPlant Modeler Connect

     
     Questions about this article, topic, or product? Click here. 

    Scaler, Symbols or Item code are missing for TAP_CONNECTION error message when Branch Connected Through Stub-In Tapport

    Applies To 
    Product(s):  OpenPlant Isometrics Manager & AutoPlant Modeler
    Version(s):  08.11.09.458 & 08.11.11.135
    Environment:  Windows 7 (64 bit)
    Area:  Settings/Attributes
    Subarea: 
    Original Author:

    Abhijit Bute, Bentley Product Advantage Group

    AutoPLANT Modeler - OpenPlant Isometrics Manager

    Problem Description

    Using AutoPLANT Modeler & OpenPlant Isometrics Manager user is getting error as "Scaler, Symbols or item codes are missing for TAP_CONNECTION" while generating isometrics as shown below.

    Scaler, Symbols or Item code are missing for TAP_CONNECTION error message when branch connected through Stub-In tap port. 


    Steps to Resolve

    1. Open Class Editor and go to File>Open navigate to project path.

    2. Open ‘OpenPlant_3D.01.04.ecschema.xml’ & supplement it with "OpenPlant_3D_Supplemental_Isometrics_Isoextractor.01.04.ecschema.xml" Schema.

    3. Search TAP_CONNECTION class.

    4. Change the value in “Item Code” from this.COMPONENT_NAME to “TAG”

      Note - Add the string quotes " " around TAG as "TAG".

    5. Save & close schema.

    6. Restart document manager generate isometric to verify result.

    OpenPlant Modeler - OpenPlant Isometrics Manager

    Problem Description

    Using OpenPlant Modeler & OpenPlant Isometrics Manager user is getting error as "Scaler, Symbols or item codes are missing for PIPE" while generating isometrics as shown below. This issue arises when important field or property is missing in OpenPlant Modeler & OpenPlant Isometrics Manager is unable to find that missing property. Adding that missing property will solve the issue.



    From Production Log, inspect the error message as shown below.

    Steps to Resolve

    1. Using Bentley Class Editor, open OpenPlant_3D.01.04.ecschema.
    2. Supplement above schema with OpenPlant_3D_Supplemental_Modeling.01.04.ecschema and OpenPlant_3D_Supplemental_ModelingViews.01.04.ecschema.

      For More information on supplementing schema click here>>>>

    3. Navigate to Plant Base Object class, switch to Properties tab. 
    4. Click on Add > New to add a new property as shown below.



    5. Enter details for Material property as shown below.



    6. Right click on newly created MATERIAL property & select Custom Attribute > Add/Remove to add custom attribute as shown below



    7. Search for OpenPlant_Physical_Catalogue_Property_Map custom attribute, using drop down arrow add this custom attribute & change schema location to OpenPlant_3D_Supplemental_Modeling.01.04 as shown below.

        

    8. Enter details as shown below.



    9. Save all the changes & verify the results as shown below.

    Still a Problem?

    If above problem still persist, then please create a Service Request and contact the Bentley Product Advantage group.  Please include a list of all relevant details to get in depth analysis for a solution or workaround.

    See Also

    http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/20662.errors-logs-messages-crashes-openplant-isometrics-manager

    Comments or Corrections?

    Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!

    • apm
    • OpenPlant Modeler Item Code Missing in OPIM
    • AutoPLANT Modeler
    • OPIM
    • OPIM item Code ECX_IE_ITEMCODE error
    • Scaler
    • Symbols or Item code are missing for TAP_CONNECTION
    • Tap connection
    • 08.11.09.458
    • OpenPlant Isometrics Manager
    • Share
    • History
    • More
    • Cancel
    • Abhijit Bute Created by Bentley Colleague Abhijit Bute
    • When: Tue, Jun 9 2015 8:09 AM
    • Kestutis Mitkus Last revision by Bentley Colleague Kestutis Mitkus
    • When: Wed, Dec 12 2018 10:16 AM
    • Revisions: 9
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2021 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies