Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
  • Welcome
  • Products
  • Support
  • About
  • More
  • Cancel
AutoPLANT | OpenPlant | PlantWise
  • Product Communities
  • More
AutoPLANT | OpenPlant | PlantWise
AutoPLANT | OpenPlant | PlantWise Wiki Error:[5] Detail Sketch Not found in cell libraries
    • Sign in
    • -AutoPLANT | Bentley Raceway and Cable Management | OpenPlant | PlantWise Wiki
      • -OpenPlant
        • +CONNECT Services - OpenPlant
        • +Example Configuration - CONNECT Edition
        • +Installations - OpenPlant CONNECT Edition Applications
        • +OpenPlant Download Links & Videos
        • OpenPlant Product Compatibility
        • +OpenPlant Modeler CONNECT
        • +OpenPlant PID CONNECT
        • +OpenPlant Isometrics Manager CONNECT
        • +OpenPlant Orthographics Manager CONNECT
        • +OpenPlant Support Engineering CONNECT
        • +OpenPlant Project Administrator CONNECT
        • +OpenPlant CONNECT Edition-PlantSight Integration
        • +OpenPlant Modeler v8i
        • -OpenPlant Isometrics Manager v8i
          • -OpenPlant Isometrics Manager for OpenPlant
            • Installation/Upgradation Steps for OpenPlant Isometrics Manager
            • -Errors, Logs, Messages, Crashes - OpenPlant Isometrics Manager
              • Description for Bolts, Gaskets not Getting Inside Isometric BOM & Showing as "NODESC"
              • Displays Error[5]-DWG creation failed While Generating Isometric Output as DWG Format
              • Error Copying Document to the Client While Loading I-model
              • Error: = 1603 While Installation of OpenPlant Isometrics Manager
              • Error "Empty Path Name is not legal" Pops Up at Startup
              • Error Distance Between Gasket [Gasket][GUID No] & Adjoin Components could be more than 1.5
              • Error Loading I-model: Unable to Validate Expression Properties
              • Error on Loading I-model from Managed Workspace in OpenPlant Isometrics Manager
              • Error While Reading ECSchema 'OpenPlant_3D.01.04
              • Error[0]:SYS mismatch CP/CP count: component ID = 1 in OpenPlant Isometrics Manager
              • Error [5] Unable to locate addon (ID=XXX) to component
              • Error:[5] Detail Sketch Not found in cell libraries
              • Error: i-model master unit 'Feet' is not matching with 'MILLIMETERS', specified as PROJ_MASTER_UNIT in OPModeler_MMetric project pcf. You might have selected wrong workspace project or i-model.
              • Error: An internal error occurred.Could not start responsive Microstation server.
              • Error: Could not start IMODEL Engine Process in 60 seconds.
              • Error: Exception has been thrown by the target of an invocation. Argument 'ecProperty for msi_TransactionID' cannot be a null value
              • ERROR: Weld[WELD]123xxxxxxxxGUID is not connected to Pipe
              • Fixing Sheet No. Issues in OpenPlant Isometrics Manager
              • OpenPlant Isometrics Manager Bill of Material Components sort by lines.
              • Scaler, Symbols or Item code are missing for TAP_CONNECTION error message when Branch Connected Through Stub-In Tapport
              • Unable to Launch OpenPlant Isometrics Manager
              • Unable to Load i-model in OpenPlant Isometrics Manager
              • Error[0]: no DEF entry for Scalar Type DUMMYPIPE in Openplant Isometrics Manager
            • +Open/Save - OpenPlant Isometrics Manager
            • +Processing - OpenPlant Isometrics Manager
            • +Settings/Attributes - OpenPlant Isometrics Manager
          • +OpenPlant Isometrics Manager for AutoPLANT
          • +Release Notes - OpenPlant Isometrics Manager
          • OpenPlant Isometrics Manager [FAQ]
        • +OpenPlant Project Administrator v8i
        • +OpenPlant PID v8i
        • +OpenPlant Orthographics Manager v8i
        • +OpenPlant Support Engineering v8i
        • +OpenPlant ModelServer v8i
        • +OpenPlant Reporting v8i
        • How to Connect with Bentley Technical Support Team using Microsoft Teams
        • How to Connect with Bentley Technical Support Team using Microsoft Teams via Browser
      • +Bentley AutoPLANT
      • +Bentley Navigator
      • +Bentley PlantSpace
      • +Plant Project Tools
      • +Bentley Raceway and Cable Management
      • i-model Composition Service for S3D
      • Working from home with OpenPlant
      • Working from home with Bentley Raceway and Cable Management
      • Working from home with AutoPLANT Modeler
    • How to Associate the Specification Based on Service in OpenPlant Modeler Connect

     
     Questions about this article, topic, or product? Click here. 

    Error:[5] Detail Sketch Not found in cell libraries

    Applies To 
    Product(s):  OpenPlant Isometrics Manager
    Version(s):  08.11.09.XXX (SS5) | 08.11.11.XXX (SS6)
    Environment:  Windows 7/8.1/10 (64 bit)
    Area:  Settings/Attributes
    Subarea:  Cell Template
    Original Author:  Rahul Kumar, Bentley Product Advantage Group

    Overview

    In OpenPlant Isometrics Manager, during isometrics generation it displays details sketch error as Error:[N] Detail Sketch Not found in cell libraries: CELLNAME

    Problem Description

    In OpenPlant Isometrics Manager, user might receive an error as described below:

    Error:[5] Detail Sketch Not found in cell libraries: TEST3 Error:[5] Detail Sketch Not found in cell libraries: TEST2 Error:[5] Detail Sketch Not found in cell libraries: TEST

    In below log, it can be noticed that it throws errors for 3 missing cell files namely TEST3, TEST2 & TEST. 

    Below steps will aid user to avoid such errors. Below example and error caused shown here using OpenPlant Modeler and OpenPlant Isometrics Manager. However similar instances might occur using AutoPLANT modeler and OpenPlant Isometrics Manager.

    Steps to Resolve

    The above errors mentioned due to missing cel file present inside the CELL folder which is found under each styles for isometrics. User has to check detail_sketch.cel file based on the cel defined inside the OpenPlant Modeler. 

    Check list

    1. In OpenPlant Modeler, list out the cell name defined on selected component under Detail_sketch field.

    2. Under Isometrics Folder, check style folder which contain file name as detail_sketch.cel.





      Note: Removing the detail_sketch.cel name from style.cfg file also causes the same error.

    3. From Isometric configuration dialog, check what option has been set.



    4. Check for correct cell name defined inside the detail_sketch file.





    5. Define new cell file if it is missing in library. To add user may please refer >>>this Link. 

    Still a Problem?

    If above problem still persist, then please create a Service Request and contact Bentley Product Advantage group along with the list of all relevant details to get in depth analysis and for possible solution or workarounds. 

    See Also

    http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/19701.how-to-add-detail-sketches-in-openplant-isometrics-manager-using-openplant-modeler

    http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/13885.how-to-add-detail-sketches-in-openplant-isometric 

    Comments or Corrections?

    Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!

    • OpenPlant Modeler
    • 08.11.09.XXX
    • OpenPlant Isometrics Manager
    • Detail Sketch Error
    • Share
    • History
    • More
    • Cancel
    • Rahul Kumar Created by Bentley Colleague Rahul Kumar
    • When: Wed, Jun 17 2015 1:28 AM
    • Kestutis Mitkus Last revision by Bentley Colleague Kestutis Mitkus
    • When: Wed, Dec 12 2018 11:21 AM
    • Revisions: 9
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2021 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies