08.11.09.XXX (SS5)
Currently OpenPlant Isometrics manager in Isometric generation does not pull the same Spool ID’s as assigned in the AutoPLANT Modeler. OpenPlant Isometrics manager automatically assigns spools based on flange and other connection criteria. Below steps can be used to get spooled from AutoPLANT to Isometrics.
#-----------------------------------------------------------------------------# A sample AutoPLANT SPOOLID report#-----------------------------------------------------------------------------REPORT = APSPOOLID INCLUDE = IE_TYPE = CT_PIPE INCLUDE = IE_FIELD=0 INCLUDE = IE_FIELD= COLUMN = 15:C:APSPOOLID GROUP = APSPOOLID SORT = APSPOOLID SEP = @SORTHEADERS = 0
TEXT = @ ------------------ TEXT = @ AutoPLANT Spool IDs TEXT = @ ------------------ Write =END
#-----------------------------------------------------------------------------# The COMBI report combine the SHP and FLD and APSPOOLID report into a single report# and attaches it to textnode 60 in the isometric#-----------------------------------------------------------------------------REPORT = combi WRITE = shp TEXT = @ TEXT = @ WRITE = fld TEXT = @ TEXT = @ WRITE = APSPOOLID NODE = 60END
http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/23034.fixing-spec-change-cell-file-in-openplant-isometrics-manager