You are currently reviewing an older revision of this page.
Currently OpenPlant Isometrics manager in Isometric generation does not pull the same spool id’s as assigned in the AutoPLANT Model. OpenPlant Isometrics manager automatically assigns spools based on flange and other connection criteria. Below steps can be used to get spooled from AutoPLANT to Isometrics.
#-----------------------------------------------------------------------------# A sample SPOOLID report#-----------------------------------------------------------------------------REPORT = SPOOLID include = IE_TYPE = CT_PIPE COLUMN = 15:C:SPOOLID GROUP = SPOOLID SORT = SPOOLID SEP = @SORTHEADERS = 1
TEXT = @ ------------------ TEXT = @ Spool IDs TEXT = @ ------------------ Write =END
#-----------------------------------------------------------------------------# The COMBI report combine the SHP and FLD and SPOOLID report into a single report# and attaches it to textnode 60 in the isometric#-----------------------------------------------------------------------------REPORT = combi WRITE = shp TEXT = @ TEXT = @ WRITE = fld TEXT = @ TEXT = @ WRITE = SPOOLID NODE = 60END
http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/23034.fixing-spec-change-cell-file-in-openplant-isometrics-manager