In OpenPlant Isometrics Manager, Setting the Border Size to avoid Overlap with the pipeline or other objects.
In user’s customized environment, sometimes few pipelines produces drawing with an overlap or crosses the Drawing window part which creates problem for the user. In OpenPlant Isometrics Manager, using configuration variable we can control the area of generating isometrics lines to avoid such overlaps. Below steps will provide solution to all problems discussed above. This has been realized in context with Both AutoPLANT Modeler and OpenPlant Modeler. Below case has been taken using OpenPlant Modeler and OpenPlant Isometrics Manager.
http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/12636.setting-file-type-dgn-or-dwg-and-paper-setting