In OpenPlant Isometrics Manager, Isometric drawing nomenclature formatting required by user. Please find below explanations and illustrates on changing the format.
In OpenPlant Isometrics Manager, the isometrics output drawing name contains three parameters, LINENUMBER, ISO, and NUMBER. As per the Project requirement users might need to change this to some different formats. Currently, the NUMBER property starts with the format as 1, 2, 3…and so on. The requirement is to get the NUMBER property formatted and to produce the output as 01, 02, 03…etc. Notice the below changes in schema files under the ISO_SHEET class will aid user to achieve this settings. This has been shown in Context with OpenPlant Modeler and OpenPlant Isometrics Manager.
http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/12636.setting-file-type-dgn-or-dwg-and-paper-setting