To customize default OD value for End types and based on size in OpenPlant Modeler.
User requirement was to modify the OD for various End Types. Currently during spec creation, user wanted to set the OD for end types such as Socket End, as per catalog used for project standard value. By default it has been set for 1.2 X OD of MAIN_PORT, RUN_PORT, BRANCH_PORT etc. User can modify the value from 1.2 to other multiple factor as per requirement. A schema modification has been required under PORT class where user can alter the calculated EC expression. Below settings has been described to change the value for a Socket end type from 1.2 to 2.0