Applies To | |
Product(s): | OpenPlant Modeler |
Version(s): | 08.11.09.XXX (SS5) | 08.11.11.XXX (SS6) |
Environment: | Windows 7/8.1/10 (64 bit) |
Area: | Component |
Subarea: | Graphics |
Original Author: | Rahul Kumar, Bentley Product Advantage Group |
To remove gasket from joints for flanged components in OpenPlant Modeler and then to OpenPlant Isometrics Manager. Refer case-1 for it. However to consider both ways to use the placement of flanges, please refer case-2 described below.
In OpenPlant Modeler, user wanted to display only bolts for flanged connection and wanted to remove GASKETS from joints. Using schema modification user should be able to get the flanged connection without Gasket and also able to generate isometrics without it. Below are the steps user could check. This has been described in context with OpenPlant Modeler and OpenPlant Isometrics Manager.
communities.bentley.com/.../how-to-create-a-custom-joint
Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!