<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>How to Assign Level for Valve Tag Using Named Expression</title><link>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/25164/how-to-assign-level-for-valve-tag-using-named-expression</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>How to Assign Level for Valve Tag Using Named Expression</title><link>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/25164/how-to-assign-level-for-valve-tag-using-named-expression</link><pubDate>Wed, 08 Aug 2018 09:24:31 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:6cef97b2-7236-476c-918b-0d740a35f194</guid><dc:creator>Deepak Singh</dc:creator><comments>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/25164/how-to-assign-level-for-valve-tag-using-named-expression#comments</comments><description>Current Revision posted to OpenPlant | AutoPLANT Wiki by Deepak Singh on 8/8/2018 9:24:31 AM&lt;br /&gt;
&lt;h1&gt;&lt;b&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/h1&gt;
&lt;div class="content-scrollable-wrapper"&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;height:126px;width:487px;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenPlant Modeler&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.11.09.XXX&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Windows 7 (64 bit)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Settings/Attributes&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;-&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Rahul Kumar, Bentley Technical Support Group&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;To set Component symbology with Valve tag i.e. &amp;nbsp;PIPELINE.NAME-Valve-Tag Name in OpenPlant Modeler using Named Expression.&lt;/p&gt;
&lt;/div&gt;
&lt;h1&gt;Background&lt;/h1&gt;
&lt;p&gt;OpenPlant component symbology is managed in the typical MicroStation fashion. It is controlled through a combination of Named Expressions (used to read attributes and assign the Element Templates accordingly) and Element Templates (where symbology is defined for the elements identified by the Named Expression).&lt;/p&gt;
&lt;p&gt;A modification in &amp;lsquo;Named Expression&amp;rsquo; should require for changing the components symbology by pipeline name which can be found under &amp;lsquo;Utilities&amp;rsquo; Menu and to customize &amp;lsquo;Element template&amp;rsquo; to define the&amp;nbsp; name and hence color to it under &amp;lsquo;Element&amp;rsquo; option.&lt;/p&gt;
&lt;p&gt;In OpenPlant Modeler, Sometimes it could be Modeler choice or as per Project specific requirement, it has been envisioned to get some piping component say Valve to different level. A modification in &amp;lsquo;Named Expression&amp;rsquo; should require for changing the Equipment level as per Valve Name and Tag Number &amp;nbsp;like &lt;b&gt;PIPELINE.NAME-VALVE-TAG &lt;/b&gt;etc. see below exercise where similar content has been described.&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Steps to Accomplish&lt;/h1&gt;
&lt;div class="content"&gt;
&lt;ol&gt;
&lt;li&gt;Go to File from Main Menu option and open DGN library files (dgnlib). See image below :&lt;br /&gt;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/3022.1.png"&gt;&lt;img alt=" " height="303" src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-43/3022.1.png" width="486" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Under Utility Menu, Select Named expression and click on OP_SYMBOLOGY_PIPING. See image below for reference.&lt;br /&gt;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/4152.1a.png"&gt;&lt;img alt=" " height="416" src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-43/4152.1a.png" width="640" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Below are the Symbology pasted to copy from here and to get it pasted to its respective Expression&amp;rsquo;s. &amp;nbsp;&lt;br /&gt;&lt;br /&gt;
&lt;p&gt;&lt;span style="text-decoration:underline;"&gt;OP_SYMBOLOGY_PIPING:&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&amp;quot;BY_LEVEL_AND_TEMPLATE:&amp;quot; &amp;amp; PIPELINE.NAME &amp;amp;&amp;nbsp; IIF( OPITEM.IsOfClass( &amp;quot;VALVE&amp;quot;, &amp;quot;OpenPlant_3D&amp;quot; ), &amp;quot;-Valve-&amp;quot;&amp;amp; OPITEM.NAME &amp;amp;&amp;quot;:&amp;quot;,&amp;quot;:&amp;quot;)&amp;nbsp; &amp;amp; &amp;quot;OpenPlant\Piping\&amp;quot; &amp;amp;&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&amp;nbsp; IIF( OPITEM.IsOfClass( &amp;quot;INSTRUMENT&amp;quot;, &amp;quot;OpenPlant_3D&amp;quot; ), &amp;quot;Instrument:&amp;quot;,&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; IIF( OPITEM.IsOfClass( &amp;quot;CONTROL_VALVE&amp;quot;, &amp;quot;OpenPlant_3D&amp;quot; ), &amp;quot;Instrument:&amp;quot;,&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; IIF( OPITEM.NOMINAL_DIAMETER &amp;lt;= 100 , &amp;quot;DiameterRange1:&amp;quot;,&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; IIF( OPITEM.NOMINAL_DIAMETER &amp;gt; 100 AND OPITEM.NOMINAL_DIAMETER &amp;lt;= 200, &amp;quot;DiameterRange2:&amp;quot;,&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &amp;nbsp;&amp;nbsp;IIF( OPITEM.NOMINAL_DIAMETER &amp;gt; 200 AND OPITEM.NOMINAL_DIAMETER &amp;lt;= 300, &amp;quot;DiameterRange3:&amp;quot;,&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; IIF( OPITEM.NOMINAL_DIAMETER &amp;gt; 300 AND OPITEM.NOMINAL_DIAMETER &amp;lt;= 400, &amp;quot;DiameterRange4:&amp;quot;,&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; IIF( OPITEM.NOMINAL_DIAMETER &amp;gt; 400 AND OPITEM.NOMINAL_DIAMETER &amp;lt;= 500, &amp;quot;DiameterRange5:&amp;quot;,&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; IIF( OPITEM.NOMINAL_DIAMETER &amp;gt; 500, &amp;quot;DiameterRange6:&amp;quot;, &amp;quot;Default:&amp;quot; ) ) ) ) ) ) ) ) &amp;amp; &amp;quot;Model&amp;quot;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Note:&lt;/b&gt;&lt;i&gt;Make sure to copy the strings correctly.&lt;/i&gt;&lt;/p&gt;
&lt;i&gt;&lt;br /&gt;&lt;/i&gt;&lt;/li&gt;
&lt;li&gt;Save each Expression which turns&amp;nbsp;&lt;b&gt;blue&lt;/b&gt;&lt;b&gt;.&lt;/b&gt;&amp;nbsp;Save option will get enabled once you modify the Expressions: See below for reference.&lt;br /&gt;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/2a.png"&gt;&lt;img alt=" " height="432" src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2a.png" width="716" /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Launch OpenPlant Modeler and Verify results. See images below:&amp;nbsp;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;b&gt;Valve Level as &amp;lsquo;PIPELINE.NAME-Valve-Tag ( 1-RW-001-B2-Valve-HV10)&amp;rsquo;&lt;br /&gt;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/3603.3a.png"&gt;&lt;img alt=" " height="193" src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-43/3603.3a.png" width="397" /&gt;&lt;/a&gt;&lt;/b&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;h3&gt;See Also&lt;/h3&gt;
&lt;p&gt;&lt;a href="http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/19761.to-assign-separate-level-for-component-using-named-expressions"&gt;communities.bentley.com/.../19761.to-assign-separate-level-for-component-using-named-expressions&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;See Video&lt;/h3&gt;
&lt;p&gt;&lt;a href="https://communities.bentley.com/products/plant/m/plant_design_and_engineering_files/273300"&gt;communities.bentley.com/.../273300&lt;/a&gt;&lt;/p&gt;
&lt;/div&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: OpenPlant Modeler, Tags, Valve Tag in OpenPlant Modeler, 08.11.09.XXX, Expression by Properties, Named Expression, Valve Tag&lt;/div&gt;
</description></item><item><title>How to Assign Level for Valve Tag Using Named Expression</title><link>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/25164/how-to-assign-level-for-valve-tag-using-named-expression/revision/2</link><pubDate>Mon, 09 Nov 2015 15:03:20 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:6cef97b2-7236-476c-918b-0d740a35f194</guid><dc:creator>Rahul Kumar</dc:creator><comments>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/25164/how-to-assign-level-for-valve-tag-using-named-expression#comments</comments><description>Revision 2 posted to OpenPlant | AutoPLANT Wiki by Rahul Kumar on 11/9/2015 3:03:20 PM&lt;br /&gt;
&lt;h1&gt;&lt;b&gt;&lt;img src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" height="60" alt=" " /&gt;&lt;/b&gt;&lt;/h1&gt;
&lt;div class="content-scrollable-wrapper"&gt;
&lt;table border="0" style="border:0px solid #dce5f0;width:487px;height:126px;background-color:#dce5f0;"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenPlant Modeler&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.11.09.XXX&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Windows 7 (64 bit)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Settings/Attributes&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;-&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Rahul Kumar, Bentley Technical Support Group&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;To set Component symbology with Valve tag i.e. &amp;nbsp;PIPELINE.NAME-Valve-Tag Name in OpenPlant Modeler using Named Expression.&lt;/p&gt;
&lt;/div&gt;
&lt;h1&gt;Background&lt;/h1&gt;
&lt;p&gt;OpenPlant component symbology is managed in the typical MicroStation fashion. It is controlled through a combination of Named Expressions (used to read attributes and assign the Element Templates accordingly) and Element Templates (where symbology is defined for the elements identified by the Named Expression).&lt;/p&gt;
&lt;p&gt;A modification in &amp;lsquo;Named Expression&amp;rsquo; should require for changing the components symbology by pipeline name which can be found under &amp;lsquo;Utilities&amp;rsquo; Menu and to customize &amp;lsquo;Element template&amp;rsquo; to define the&amp;nbsp; name and hence color to it under &amp;lsquo;Element&amp;rsquo; option.&lt;/p&gt;
&lt;p&gt;In OpenPlant Modeler, Sometimes it could be Modeler choice or as per Project specific requirement, it has been envisioned to get some piping component say Valve to different level. A modification in &amp;lsquo;Named Expression&amp;rsquo; should require for changing the Equipment level as per Valve Name and Tag Number &amp;nbsp;like &lt;b&gt;PIPELINE.NAME-VALVE-TAG &lt;/b&gt;etc. see below exercise where similar content has been described.&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Steps to Accomplish&lt;/h1&gt;
&lt;div class="content"&gt;&lt;ol&gt;
&lt;li&gt;Go to File from Main Menu option and open DGN library files (dgnlib). See image below :&lt;br /&gt;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/3022.1.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-43/3022.1.png" width="486" height="303" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Under Utility Menu, Select Named expression and click on OP_SYMBOLOGY_PIPING. See image below for reference.&lt;br /&gt;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/4152.1a.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-43/4152.1a.png" width="640" height="416" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Below are the Symbology pasted to copy from here and to get it pasted to its respective Expression&amp;rsquo;s. &amp;nbsp;&lt;br /&gt;&lt;br /&gt;
&lt;p&gt;&lt;span style="text-decoration:underline;"&gt;OP_SYMBOLOGY_PIPING:&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&amp;quot;BY_LEVEL_AND_TEMPLATE:&amp;quot; &amp;amp; PIPELINE.NAME &amp;amp;&amp;nbsp; IIF( OPITEM.IsOfClass( &amp;quot;VALVE&amp;quot;, &amp;quot;OpenPlant_3D&amp;quot; ), &amp;quot;-Valve-&amp;quot;&amp;amp; OPITEM.NAME &amp;amp;&amp;quot;:&amp;quot;,&amp;quot;:&amp;quot;)&amp;nbsp; &amp;amp; &amp;quot;OpenPlant\Piping\&amp;quot; &amp;amp;&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&amp;nbsp; IIF( OPITEM.IsOfClass( &amp;quot;INSTRUMENT&amp;quot;, &amp;quot;OpenPlant_3D&amp;quot; ), &amp;quot;Instrument:&amp;quot;,&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; IIF( OPITEM.IsOfClass( &amp;quot;CONTROL_VALVE&amp;quot;, &amp;quot;OpenPlant_3D&amp;quot; ), &amp;quot;Instrument:&amp;quot;,&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; IIF( OPITEM.NOMINAL_DIAMETER &amp;lt;= 100 , &amp;quot;DiameterRange1:&amp;quot;,&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; IIF( OPITEM.NOMINAL_DIAMETER &amp;gt; 100 AND OPITEM.NOMINAL_DIAMETER &amp;lt;= 200, &amp;quot;DiameterRange2:&amp;quot;,&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &amp;nbsp;&amp;nbsp;IIF( OPITEM.NOMINAL_DIAMETER &amp;gt; 200 AND OPITEM.NOMINAL_DIAMETER &amp;lt;= 300, &amp;quot;DiameterRange3:&amp;quot;,&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; IIF( OPITEM.NOMINAL_DIAMETER &amp;gt; 300 AND OPITEM.NOMINAL_DIAMETER &amp;lt;= 400, &amp;quot;DiameterRange4:&amp;quot;,&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; IIF( OPITEM.NOMINAL_DIAMETER &amp;gt; 400 AND OPITEM.NOMINAL_DIAMETER &amp;lt;= 500, &amp;quot;DiameterRange5:&amp;quot;,&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; IIF( OPITEM.NOMINAL_DIAMETER &amp;gt; 500, &amp;quot;DiameterRange6:&amp;quot;, &amp;quot;Default:&amp;quot; ) ) ) ) ) ) ) ) &amp;amp; &amp;quot;Model&amp;quot;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Note:&lt;/b&gt;&lt;i&gt;Make sure to copy the strings correctly.&lt;/i&gt;&lt;/p&gt;
&lt;i&gt;&lt;br /&gt;&lt;/i&gt;&lt;/li&gt;
&lt;li&gt;Save each Expression which turns&amp;nbsp;&lt;b&gt;blue&lt;/b&gt;&lt;b&gt;.&lt;/b&gt;&amp;nbsp;Save option will get enabled once you modify the Expressions: See below for reference.&lt;br /&gt;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/2a.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2a.png" width="716" height="432" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Launch OpenPlant Modeler and Verify results. See images below:&amp;nbsp;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;b&gt;Valve Level as &amp;lsquo;PIPELINE.NAME-Valve-Tag ( 1-RW-001-B2-Valve-HV10)&amp;rsquo;&lt;br /&gt;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/3603.3a.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-43/3603.3a.png" width="397" height="193" alt=" " /&gt;&lt;/a&gt;&lt;/b&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;a href="http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/19761.to-assign-separate-level-for-component-using-named-expressions"&gt;communities.bentley.com/.../19761.to-assign-separate-level-for-component-using-named-expressions&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;Bentley&amp;#39;s Technical Support Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;
&lt;/div&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: OpenPlant Modeler, Tags, 08.11.09.XXX, Expression by Properties, Named Expression, Valve Tag&lt;/div&gt;
</description></item><item><title>How to Assign Level for Valve Tag Using Named Expression</title><link>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/25164/how-to-assign-level-for-valve-tag-using-named-expression/revision/1</link><pubDate>Mon, 09 Nov 2015 15:02:58 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:6cef97b2-7236-476c-918b-0d740a35f194</guid><dc:creator>Rahul Kumar</dc:creator><comments>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/25164/how-to-assign-level-for-valve-tag-using-named-expression#comments</comments><description>Revision 1 posted to OpenPlant | AutoPLANT Wiki by Rahul Kumar on 11/9/2015 3:02:58 PM&lt;br /&gt;
&lt;h1&gt;&lt;b&gt;&lt;img src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" height="60" alt=" " /&gt;&lt;/b&gt;&lt;/h1&gt;
&lt;div class="content-scrollable-wrapper"&gt;
&lt;table border="0" style="border:0px solid #dce5f0;width:387px;height:115px;background-color:#dce5f0;"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenPlant Modeler&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.11.09.XXX&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Windows 7 (64 bit)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Settings/Attributes&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;-&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Rahul Kumar, Bentley Technical Support Group&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;To set Component symbology with Valve tag i.e. &amp;nbsp;PIPELINE.NAME-Valve-Tag Name in OpenPlant Modeler using Named Expression.&lt;/p&gt;
&lt;/div&gt;
&lt;h1&gt;Background&lt;/h1&gt;
&lt;p&gt;OpenPlant component symbology is managed in the typical MicroStation fashion. It is controlled through a combination of Named Expressions (used to read attributes and assign the Element Templates accordingly) and Element Templates (where symbology is defined for the elements identified by the Named Expression).&lt;/p&gt;
&lt;p&gt;A modification in &amp;lsquo;Named Expression&amp;rsquo; should require for changing the components symbology by pipeline name which can be found under &amp;lsquo;Utilities&amp;rsquo; Menu and to customize &amp;lsquo;Element template&amp;rsquo; to define the&amp;nbsp; name and hence color to it under &amp;lsquo;Element&amp;rsquo; option.&lt;/p&gt;
&lt;p&gt;In OpenPlant Modeler, Sometimes it could be Modeler choice or as per Project specific requirement, it has been envisioned to get some piping component say Valve to different level. A modification in &amp;lsquo;Named Expression&amp;rsquo; should require for changing the Equipment level as per Valve Name and Tag Number &amp;nbsp;like &lt;b&gt;PIPELINE.NAME-VALVE-TAG &lt;/b&gt;etc. see below exercise where similar content has been described.&amp;nbsp;&lt;/p&gt;
&lt;h1&gt;Steps to Accomplish&lt;/h1&gt;
&lt;div class="content"&gt;&lt;ol&gt;
&lt;li&gt;Go to File from Main Menu option and open DGN library files (dgnlib). See image below :&lt;br /&gt;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/3022.1.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-43/3022.1.png" width="486" height="303" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Under Utility Menu, Select Named expression and click on OP_SYMBOLOGY_PIPING. See image below for reference.&lt;br /&gt;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/4152.1a.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-43/4152.1a.png" width="640" height="416" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Below are the Symbology pasted to copy from here and to get it pasted to its respective Expression&amp;rsquo;s. &amp;nbsp;&lt;br /&gt;&lt;br /&gt;
&lt;p&gt;&lt;span style="text-decoration:underline;"&gt;OP_SYMBOLOGY_PIPING:&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&amp;quot;BY_LEVEL_AND_TEMPLATE:&amp;quot; &amp;amp; PIPELINE.NAME &amp;amp;&amp;nbsp; IIF( OPITEM.IsOfClass( &amp;quot;VALVE&amp;quot;, &amp;quot;OpenPlant_3D&amp;quot; ), &amp;quot;-Valve-&amp;quot;&amp;amp; OPITEM.NAME &amp;amp;&amp;quot;:&amp;quot;,&amp;quot;:&amp;quot;)&amp;nbsp; &amp;amp; &amp;quot;OpenPlant\Piping\&amp;quot; &amp;amp;&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&amp;nbsp; IIF( OPITEM.IsOfClass( &amp;quot;INSTRUMENT&amp;quot;, &amp;quot;OpenPlant_3D&amp;quot; ), &amp;quot;Instrument:&amp;quot;,&amp;nbsp;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; IIF( OPITEM.IsOfClass( &amp;quot;CONTROL_VALVE&amp;quot;, &amp;quot;OpenPlant_3D&amp;quot; ), &amp;quot;Instrument:&amp;quot;,&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; IIF( OPITEM.NOMINAL_DIAMETER &amp;lt;= 100 , &amp;quot;DiameterRange1:&amp;quot;,&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; IIF( OPITEM.NOMINAL_DIAMETER &amp;gt; 100 AND OPITEM.NOMINAL_DIAMETER &amp;lt;= 200, &amp;quot;DiameterRange2:&amp;quot;,&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; &amp;nbsp;&amp;nbsp;IIF( OPITEM.NOMINAL_DIAMETER &amp;gt; 200 AND OPITEM.NOMINAL_DIAMETER &amp;lt;= 300, &amp;quot;DiameterRange3:&amp;quot;,&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; IIF( OPITEM.NOMINAL_DIAMETER &amp;gt; 300 AND OPITEM.NOMINAL_DIAMETER &amp;lt;= 400, &amp;quot;DiameterRange4:&amp;quot;,&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; IIF( OPITEM.NOMINAL_DIAMETER &amp;gt; 400 AND OPITEM.NOMINAL_DIAMETER &amp;lt;= 500, &amp;quot;DiameterRange5:&amp;quot;,&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;strong&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp; IIF( OPITEM.NOMINAL_DIAMETER &amp;gt; 500, &amp;quot;DiameterRange6:&amp;quot;, &amp;quot;Default:&amp;quot; ) ) ) ) ) ) ) ) &amp;amp; &amp;quot;Model&amp;quot;&lt;/strong&gt;&lt;/p&gt;
&lt;p&gt;&lt;b&gt;Note:&lt;/b&gt;&lt;i&gt;Make sure to copy the strings correctly.&lt;/i&gt;&lt;/p&gt;
&lt;i&gt;&lt;br /&gt;&lt;/i&gt;&lt;/li&gt;
&lt;li&gt;Save each Expression which turns&amp;nbsp;&lt;b&gt;blue&lt;/b&gt;&lt;b&gt;.&lt;/b&gt;&amp;nbsp;Save option will get enabled once you modify the Expressions: See below for reference.&lt;br /&gt;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/2a.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2a.png" width="716" height="432" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Launch OpenPlant Modeler and Verify results. See images below:&amp;nbsp;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;b&gt;Valve Level as &amp;lsquo;PIPELINE.NAME-Valve-Tag ( 1-RW-001-B2-Valve-HV10)&amp;rsquo;&lt;br /&gt;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/3603.3a.png"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-43/3603.3a.png" width="397" height="193" alt=" " /&gt;&lt;/a&gt;&lt;/b&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;h1&gt;See Also&lt;/h1&gt;
&lt;p&gt;&lt;a href="http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/19761.to-assign-separate-level-for-component-using-named-expressions"&gt;communities.bentley.com/.../19761.to-assign-separate-level-for-component-using-named-expressions&lt;/a&gt;&lt;/p&gt;
&lt;h1&gt;Comments or Corrections?&lt;/h1&gt;
&lt;p&gt;Bentley&amp;#39;s Technical Support Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;
&lt;/div&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: OpenPlant Modeler, Tags, 08.11.09.XXX, Expression by Properties, Named Expression, Valve Tag&lt;/div&gt;
</description></item></channel></rss>