To Remove Plant Area Property from Tag of Gauge Class


Applies To
Product(s):OpenPlant Modeler
Version(s):08.11.09.XXX (SS5) | 08.11.11.XXX (SS6)
Environment: Windows 7/8.1/10 (64 bit)
Area: Component
Subarea:
Original Author:Harpreet Singh, Bentley Product Advantage Group

Overview

Modify Tag of Gauge class by removing Area property from it as shown below:

Background

In OpenPlant Modeler, tagging of Gauge class is defined in the supplemental schema of OpenPlant_3D schema and doesn’t inherit the tag from INSTRUMENT class which is defined in supplemental tagging schema. Below steps will be required to modify the tag.

Steps to Resolve

  1. In Class editor, load OpenPlant_3D and supplement it with OpenPlant_3D_Supplemental_Modeling schema.

  2. Go to GAUGE class and switch to Properties tab.

  3. Locate NAME property on the class. 



  4. In Calculated ECProperty Specification custom attribute modify both the expressions (EC and Regular expressions) to remove the highlighted portions.



  5. Final expression should look like this.



  6. Save & Close Schema.

  7. Launch OpenPlant Modeler and verify the result.


Comments or Corrections?