To include as common properties in BOM reports for Bend Point Angle & others desired properties.
In a model if there are few bends available for a pipeline which exhibit a property ANGLE (Bend Point Angle) & while generating a report based on BOM_By_Pipeline, where it has been queried by Piping Component, there are no information in report for the said property. User requirement is to furnish the same information in DGN reports. Since the property has been defined under PIPE_BEND class & not present under PIPING_COMPONENT Class, hence it does not show up in the report. Also if user modifies the reports based on multiple class selection using “Multiple Types of Items” option, then it will only show common properties in the list. To publish the information, user need to copy the desired property from its available class and paste it to PIPING_COMPONENT class. Below are the steps to check in details.
http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/4352.openplant-reporting
If above problem still persist, then please create a Service Request and contact the Bentley Product Advantage group. Please include a list of all relevant details to get in depth analysis for a solution or workaround.