OPPID - Ss6 Known Issues
Sign In
-
OpenPlant | AutoPLANT Wiki
-
OpenPlant
+
CONNECT Services - OpenPlant
+
Example Configuration - CONNECT Edition
+
Installations - OpenPlant CONNECT Edition Applications
+
OpenPlant Download Links & Videos
OpenPlant Product Compatibility
+
OpenPlant Modeler CONNECT
+
OpenPlant PID CONNECT
+
OpenPlant Isometrics Manager CONNECT
+
OpenPlant Orthographics Manager CONNECT
+
OpenPlant Support Engineering CONNECT
+
OpenPlant Project Administrator CONNECT
+
OpenPlant CONNECT Edition-PlantSight Integration
+
OpenPlant Modeler v8i
+
OpenPlant Isometrics Manager v8i
+
OpenPlant Project Administrator v8i
-
OpenPlant PID v8i
+
Application Solutions - OPPID
+
Class Editor - OpenPlant PID
+
Customization - OpenPlant PID
+
Database - Plant Project
How to Cascade Associated Item's Value from Associated Class to Fitting Class in OpenPlant PID V8i
How to cascade Associated Items value from Pipeline to Reducer using Notifier in OpenPlant PID V8i
How to Change Linestyle of Instline Electric Instrument Line for Sheet Model
How to Change the Existing Cell Component Graphics in OpenPlant PID V8i
How to Fix Modified Tag Value Upon Second Sync in OpenPlant PID V8i
How to Hide the Actuator Prompt for Control Valve in OpenPlant PID V8i
How to include custom schema in OpenPlant PID under component manager
How to Point Custom WorkSpace Location in OpenPlant PID SS10
How to set the Fail Mode List for control valve Placement in OpenPlant PID V8i
+
Properties - OpenPlant PID
-
Release Notes - OpenPlant PID
+
OPPID - SS10 Release
+
OPPID - SS4 Release
OPPID - SS5 Release
-
OPPID - SS6 Release
OPPID - Ss6 Known Issues
OPPID - SS6 Requirements
OPPID - Ss6 What is New
To Resolve Duplicate Tag Numbers Found in a project associated to an SQL Database OpenPlant PID v8i
To Resolve Missing GUID of Piping Components
To Resolve Off Page Connector showing Properties belonging to its DGN OpenPlant PID v8i
To Resolve Selected Page Connector could not be Deleted OpenPlant PID v8i
+
Training - OpenPlant PID
+
White Papers/Guidelines - OPPID
+
OpenPlant Orthographics Manager v8i
+
OpenPlant Support Engineering v8i
+
OpenPlant ModelServer v8i
+
OpenPlant Reporting v8i
How to Connect with Bentley Technical Support Team using Microsoft Teams
How to Connect with Bentley Technical Support Team using Microsoft Teams via Browser
How to get list of installed applications/programs on Windows Machine using Command Prompt.
How to get list of Windows Updates installed on the machine using Command Prompt.
How to Package WorkSpace to be Shareable to Users for OpenPlant Projects
How to find iModel.dgn file of another domain in PlantSight
How to Log New Ideas in our Aha Portal
To Clean Residual Files After Uninstalling OpenPlant
To Fix Dialog not Showing After Disconnecting Multiple Monitor Display
To Fix Error "A required privilege is not held by the client" When Generating External Reports
To Remove Embedded Schemas in OpenPlant DGN
+
Bentley AutoPLANT
+
Bentley Navigator
+
Bentley PlantSpace
+
Plant Project Tools
+
Bentley Raceway and Cable Management
i-model Composition Service for S3D
Working from home with OpenPlant
Working from home with Bentley Raceway and Cable Management
Working from home with AutoPLANT Modeler
Your Feedback is important to us!
Learning Content for OpenPlant
Questions about this article, topic, or product? Click here.
OPPID - Ss6 Known Issues
Known Issues in OpenPlant PID V8
i
(SELECTseries 6)
V08.11.11
Known Issues of OpenPlant PID V8
i
(SELECTseries 6)
Drafting:
Whenever InRun Spec Validation dialog is opened, you must Apply (green check icon) before performing any other actions. Otherwise drawing corruption could occur. To fix, use Undo
Repeated copy: After the Modify Tags dialog, if dynamic graphics do not display, click anywhere inside the drawing area. Dynamic graphics will display and you can enter location for next copy.
When cancel a pump placement onto a pipe run, a bad virtual nozzle is left behind. If not removed, that end of the pipe run can no longer be connected to. To fix,
Either Undo
Or manually select the bad virtual nozzle and Delete it.
Error moving two reducers together on same pipe run. This would be the case if you wish to move a control station along a pipe run segment.
Workaround
: Reducers should be moved individually. Ex. to move control station a little to the right
1. Drag/Move the reducer to the right of the bypass, further right
2. Move the bypass and its components
3. Drag/Move the reducer to the left of the bypass
DWG Mode:
Combustible Waste pipeline circles overlap line after Save
Oily Water pipeline circles overlap line and fill disappears after Save
Solid Fuels and Untreated Water pipelines lose shading after Save
Assembly containing multiline pipeline has preview issue
APPID Conversion
Shared cell based components in APPID converted DWG drawings cannot be exported to assemblies, or be copied and pasted via 'Copy to Clipboard' and 'Paste from Component Clipboard' options.
Please refer to BE Community site for information on Conversion of
APPID Ss5 to OPPID Ss6
Miscellaneous:
Item Browser: Highlight and Zoom options have been disabled for logical groups: pipelines, instrument loops, and assemblies. It is still possible to highlight and zoom on their individual components.
File->Compress->Options has been disabled. The "delete empty cell headers" option is disabled, so Pipelines, Instrument Loops, and Assemblies will not be removed on File->Compress.
Design History shows associated item values None, when component properties are viewed for a selected revision.
When using Interval synchronization mode, if synchronize in the middle of an operation sometimes an exception occurs in the Message Center. Operations include placing, dragging and/or manipulation commands.
Workaround
: In the Interval Synchronize dialog, press No, if in the middle of an operation
ProjectWise Integration
Integration with ProjectWise has issues due to OpenPlant PID rename.
One time solution inside ProjectWise Administrator:
1. Under Applications, select "Bentley OpenPlant PowerPID"
2. Right-click Properties
3. On the Actions tab, select Open entry
4. Press Modify button
5. Next to "Program class name" press the "..." button to browse
6. Select "OpenPlant PID v8i (SELECTseries 5)"
7. Press OK
In the "Modify Properties..." dialog
The "Program class name" has been changed to "Bentley.OpenPlantPID.Application
The "Command line that will be used to start application" has been changed to full path to "OpenPlantPID.exe"
8. Press OK for the "Modify Properties..." dialog
9. Press OK for the "Bentley OpenPlant PowerPID Properties" dialog
Integration with ProjectWise Ss4+, with "Plant" environment, has an issue creating the document. It will cause database synchronization problems. The Revision field is a VARCHAR(4) in the database. In the schema, the document revision is a double.
One time solution inside ProjectWise Administrator:
PWA->DataSource->Environments->Plant->Attributes
Double click or use right click "revision" to open the "revision Properties" dialog
In the Value tab, set the Default value to 0
In the Editing tab, set the Format string value to
"%4.1f" for one character after the decimal point
"%4.2f" for two characters after the decimal point
"%d" for no decimal point
If one time solution was not used:
If creating document with wizard, set the revision value during "Define Document Attributes"
If creating document without wizard, after creating document, open the document properties and set revision under Attributes tab
Print to PDF does not work, if Advanced Wizard is used. No Wizard option works.
Installation Order
Problems can be exhibited when trying to generate drawings via Instrumentation and Wiring in a MicroStation environment, if OpenPlant PID is installed after after I&W.
Workaround
: Observing the following installation order will prevent these problems:
1. OpenPlant PID
2. MicroStation
3. Instumentation and Wiring
OpenPlant PID documents cannot be created or edited from Vision, if OpenPlant PID is installed after Prerequisites and Common Tools.
Workaround
: Observing the following installation order will prevent these problems:
1. OpenPlant PID
2. Prerequisites and Common Tools
OpenPlant PID and Prerequisites and Common Tools installation on Windows 8.1
There are 2 possible options:
Workaround
: Prior to installing either application:
1. Start Menu's Programs and Features
2. Select "Turn window features on or off"
3. Select ".Net framework 3.5 (includes .Net 2.0 and 3.0)". Windows will install .Net 3.5 on your system, downloading files from Microsoft website.
4. Install OpenPlant PID
Workaround
:
1. Run the OpenPlant PID installer. A warning message that .NET framework 3.5 is missing appears
2. Press OK and complete installation
3. Run OpenPlant PID for the first time. It will ask to download and install .NET framework 3.5
4. Press OK, to download and install
5. Run OpenPlant PID again and it will work
Installation Error=1603 occurs when installing OpenPlant PID on a machine, which does not have any other Bentley software.
Workaround
:
1. Download and install "Microsoft Visual C++ 2005 Redistributable Package"
2. Install OpenPlant PID
AXSYS Conversion:
When doing an AXSYS to OPPID conversion, the user must be sure to open the AXSYS created dgn in the correct OPPID project. The AXSYS drawings are metric and should be opened in the OPPID_Metric project or user created metric project. If not, a unit consistency error will be displayed and the dgn will not be converted. The user must restore the backup file and open again in the correct project.
Conversion of AXSYS Dgn files: Certain classes such as REACTOR are not currently converted as the same classes as they are not supported in OpenPlant PID, where possible they are converted to the next Class in the OpenPlant Schema hierarchy such as VESSEL. If this is not possible they will be imported as a cell.
Import of AXSYS Generated OWL files: Import of modifications in the class SHELL_AND_TUBE_HEAT_EXCHANGER in AXSYS via the OWL file will fail as the version of the ISO 15926 Supplemental Schema had a missing reference. Updates made via the imodel import will work fine.