In Plant Design, few users avoid showing Threaded Weld graphically in the Isometrics, which means other weld symbol like Butt weld will be shown. To achieve this requirement following change in Schema is required. The steps are applicable to AutoPLANT Modeler and OpenPlant Isometric Manager.
Image Showing Threaded Weld before modification.
http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/23763.how-to-control-socket-weld-symbols-in-openplant-isometrics-manager/edit
Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!