Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
  • Welcome
  • Products
  • Support
  • About
  • More
  • Cancel
OpenPlant | AutoPLANT
  • Product Communities
  • More
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki How to Disable Server Tree Hierarchy in Active Tree of Item Browser
    • Sign in
    • -OpenPlant | AutoPLANT Wiki
      • -OpenPlant
        • +CONNECT Services - OpenPlant
        • +Example Configuration - CONNECT Edition
        • +Installations - OpenPlant CONNECT Edition Applications
        • +OpenPlant Download Links & Videos
        • OpenPlant Product Compatibility
        • +OpenPlant Modeler CONNECT
        • +OpenPlant PID CONNECT
        • +OpenPlant Isometrics Manager CONNECT
        • +OpenPlant Orthographics Manager CONNECT
        • +OpenPlant Support Engineering CONNECT
        • +OpenPlant Project Administrator CONNECT
        • +OpenPlant CONNECT Edition-PlantSight Integration
        • -OpenPlant Modeler v8i
          • +Component - OpenPlant Modeler
          • +Drawing Generation- OpenPlant Modeler
          • +Errors, Logs, Messages, Crashes - OpenPlant Modeler
          • +Import/Export- OpenPlant Modeler
          • +Installation - OpenPlant Modeler
          • OpenPlant HVAC-OpenPlant Modeler
          • OpenPlant Modeler [FAQ]
          • +OpenPlant Specification Generator
          • +ProjectWise - OpenPlant Modeler
          • +Properties - OpenPlant Modeler
          • +Release Notes - OpenPlant Modeler
          • +Schema - OpenPlant Modeler
          • -Settings/Attributes - OpenPlant Modeler
            • Creating an Annotation with the EC Annotation Manager
            • How to Change Default Bend Radius for Mitered Bends
            • How to Change the Default Value of Number of Segments for HVAC Mitered Elbow
            • How to change the Maximum Allowed Bend Point Angle for Mitered Pipe Bend
            • How to create a New Property & Make its Field Editable in OpenPlant Modeler
            • How to Create Annotation for Multiple Properties using EC Annotation Manager
            • How to Disable Server Tree Hierarchy in Active Tree of Item Browser
            • How to Display Elevation Differences using EC Annotation in OpenPlant Modeler
            • How to Fix Generic Valve Insertion Issue in OpenPlant Modeler
            • How to Leave Custom Length Value after using Change Spec / Change Size Option
            • How to Make Properties Values Editable in OpenPlant Modeler
            • How To Reduce Printing Time in OpenPlant Modeler
            • How to Remove Trailing Zeros from EC Annotations in OpenPlant Modeler
            • How to Set Default User in OpenPlant Modeler
            • How to Set Default Value of Nested Depth in OpenPlant Modeler
            • How to use IIF Condition in EC Expression to Cater multiple Null
            • +Named Expressions: Managing Component Symbology in OpenPlant Modeler
            • OpenPlant Configuration Variables
            • To Display Tracing on Pipeline in OpenPlant Isometric Manager
            • To Fix or Create New Elbow Radius Entry under AutoFitting Template in OpenPlant Modeler
            • To put Catalogs and Specs in a different folder out of default WorkSpace
          • +Structural Modeling Components (SMC)- OpenPlant Modeler
          • +Tasks - OpenPlant Modeler
          • +Training - OpenPlant Modeler
        • +OpenPlant Isometrics Manager v8i
        • +OpenPlant Project Administrator v8i
        • +OpenPlant PID v8i
        • +OpenPlant Orthographics Manager v8i
        • +OpenPlant Support Engineering v8i
        • +OpenPlant ModelServer v8i
        • +OpenPlant Reporting v8i
        • How to Connect with Bentley Technical Support Team using Microsoft Teams
        • How to Connect with Bentley Technical Support Team using Microsoft Teams via Browser
        • How to get list of installed applications/programs on Windows Machine using Command Prompt.
        • How to get list of Windows Updates installed on the machine using Command Prompt.
      • +Bentley AutoPLANT
      • +Bentley Navigator
      • +Bentley PlantSpace
      • +Plant Project Tools
      • +Bentley Raceway and Cable Management
      • i-model Composition Service for S3D
      • Working from home with OpenPlant
      • Working from home with Bentley Raceway and Cable Management
      • Working from home with AutoPLANT Modeler
      • Your Feedback is important to us!

    You are currently reviewing an older revision of this page.

    • History View current version

    How to Disable Server Tree Hierarchy in Active Tree of Item Browser

      Applies To 
       
      Product(s): OpenPlant Modeler
      Version(s): 08.11.09.XXX
      Environment:  Windows 7 (64 bit)
      Area:  Settings/Attributes
      Subarea: 
      Original Author: Harpreet Singh, Bentley Product Advantage Group

    Background

    By default, server tree hierarchy is imposed on active tree of Item Browser in OpenPlant Modeler. This hierarchy enforces the items in the DGN tree to be grouped under their respective parent node such as Service & Unit as shown below.

    This can be changed to group the components under their respective classes. There are different ways of achieving this in different versions which are listed in next section.

    Steps to Accomplish

    Settings in 08.11.09.440 & lower versions

    1. Launch OpenPlant Modeler from desktop or Projectwise.

    2. Go to Workspace > Preferences and select OpenPlant ModelServer category.



    3. Go to DGN Tree Settings section and set 'Impose Server Tree Hierarchy' to False and click OK.



    4. Check the Active Tree in Item Browser.

    Settings in 08.11.09.568 & higher versions

    In the latest version this setting is changed through configuration variable in OPMS.cfg file which is located in C:\Program Files (x86)\Bentley\OpenPlantModeler V8i\OpenPlantModeler\config\appl folder.

    For Standalone mode

    1. Open your project pcf file in the notepad and add below configuration variable.

      OPM_OPMS_SETTING_DISABLE_SERVER_TREE_HIERARCHY = 1

    2. Save the changes in PCF file.

    3. Exit from OpenPlant Modeler and reload it to verify the result.

    Note: This will be a project specific change i.e. project where this variable is defined will have disabled server tree hierarchy.

    For Managed workspace

    1. Launch ProjectWise Administrator and login to your datasource.
    2. Go to Project node and select project CSB.
    3. In the CSB properties add new variable in the configuration tab.

    4. Add the value '1' as shown below and click OK.



    5. Click OK on all subsequent dialogs to apply the changes.

    6. Reload OpenPlant Modeler and verify the result.

    Comments or Corrections?

    Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2021 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies