You are currently reviewing an older revision of this page.
Overview:
During isometrics generation in OpenPlant Isometrics Manager, below steps provides information on dimensioning of Gasket and Valve Separately.
Problem Description:
While generating Isometric Sheet, User requires that the Gasket and Valve are dimensioned Separately.
Steps to Complete:
1) Launch Isometric Manager
2) Under the Tools Tab> Comfigurations> Isometric Styles> uncheck (Combine Gasket with Flange)
3) Check the box ( Dimension Gasket )
4) Save Changes and close Configuration Manager and regenerate Iso Sheet.
See Also :
http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/13393.settingsattributes-openplant-isometrics-manager
http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/4351.openplant-isometrics-manager
Comments or Corrections?