Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
OpenPlant | AutoPLANT
  • Product Communities
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki To Pick Reduced Half Coupling under Branch Table Automatically in OpenPlant Modeler
    • Sign In
    • -OpenPlant | AutoPLANT Wiki
      • -OpenPlant
        • +CONNECT Services - OpenPlant
        • +Example Configuration - CONNECT Edition
        • +Installations - OpenPlant CONNECT Edition Applications
        • +OpenPlant Download Links & Videos
        • OpenPlant Product Compatibility
        • +OpenPlant Modeler CONNECT
        • +OpenPlant PID CONNECT
        • +OpenPlant Isometrics Manager CONNECT
        • +OpenPlant Orthographics Manager CONNECT
        • +OpenPlant Support Engineering CONNECT
        • +OpenPlant Project Administrator CONNECT
        • +OpenPlant CONNECT Edition-PlantSight Integration
        • -OpenPlant Modeler v8i
          • +Component - OpenPlant Modeler
          • +Drawing Generation- OpenPlant Modeler
          • +Errors, Logs, Messages, Crashes - OpenPlant Modeler
          • +Import/Export- OpenPlant Modeler
          • +Installation - OpenPlant Modeler
          • OpenPlant HVAC-OpenPlant Modeler
          • OpenPlant Modeler [FAQ]
          • -OpenPlant Specification Generator
            • Error in Spec Gen does not load EC Class Name when Catalog is loaded
            • Field Reference Description in OpenPlant Modeler
            • Gaskets Not Converted from PSDS Spec to OpenPlant Modeler Spec
            • How to Convert AutoPLANT PDW Catalog to OpenPlant Modeler Format Using Exchange Option of SpecGen
            • How to Convert PSDS Catalog/Spec to OpenPlant Format
            • How to Correct Spec Changes Using Spec Validation Tool
            • How to Create New Spec in OpenPlant Specification Generator
            • How to Delete-Modify Sections in Specification Generator
            • How To Filter data with Multiple Selection in Specification Generator
            • How to Fix Unit Conversion Issue in OpenPlant Specification Generator
            • How to Include Branch Code Inside Branch Table For Specification Generator in OpenPlant Modeler
            • How to Modify Static Text of Custom Description in OpenPlant Specification Generator
            • +How to Use AutoPlant Catalogs to Create OpenPlant Spec using SpecGen
            • Lap Joint Stub End Not Converted from PSDS Spec to OpenPlant Modeler Spec
            • Olet Section Doesn't Show All Sizes From Catalog in Specification Generator
            • OpenPlant End Condition Long Descriptions
            • To Add Custom Description in a Field to Populate in OpenPlant Modeler
            • To Add EC_CLASS_NAME for Component Table in Catalog Editor
            • To Add LookUp Value in Spec Grid during Placement of Component in OpenPlant Modeler
            • To Add Support Class Property to be Read by Specification in OpenPlant Modeler
            • To Convert Nozzle Data from PSDS to OpenPlant Modeler Spec
            • To Create Missing FLOW_METER Class data in OpenPlant Modeler
            • To Create Missing SIGHT_GLASS Class data in OpenPlant Modeler
            • To Define Default Value of Branch Code for Piping Component
            • To Fix Multiple Duplicate Records Showing in Catalog Editor Interface
            • To Import Access Specification Reports in Excel
            • To Modify Default Outside Diameter Value for End Types in OpenPlant Modeler
            • To Pick Reduced Half Coupling under Branch Table Automatically in OpenPlant Modeler
            • Use Of Reinforced Branch Connection Types Using Branch Table
          • +ProjectWise - OpenPlant Modeler
          • +Properties - OpenPlant Modeler
          • +Release Notes - OpenPlant Modeler
          • +Schema - OpenPlant Modeler
          • +Settings/Attributes - OpenPlant Modeler
          • +Structural Modeling Components (SMC)- OpenPlant Modeler
          • +Tasks - OpenPlant Modeler
          • +Training - OpenPlant Modeler
        • +OpenPlant Isometrics Manager v8i
        • +OpenPlant Project Administrator v8i
        • +OpenPlant PID v8i
        • +OpenPlant Orthographics Manager v8i
        • +OpenPlant Support Engineering v8i
        • +OpenPlant ModelServer v8i
        • +OpenPlant Reporting v8i
        • How to Connect with Bentley Technical Support Team using Microsoft Teams
        • How to Connect with Bentley Technical Support Team using Microsoft Teams via Browser
        • How to get list of installed applications/programs on Windows Machine using Command Prompt.
        • How to get list of Windows Updates installed on the machine using Command Prompt.
        • How to Package WorkSpace to be Shareable to Users for OpenPlant Projects
        • How to find iModel.dgn file of another domain in PlantSight
      • +Bentley AutoPLANT
      • +Bentley Navigator
      • +Bentley PlantSpace
      • +Plant Project Tools
      • +Bentley Raceway and Cable Management
      • i-model Composition Service for S3D
      • Working from home with OpenPlant
      • Working from home with Bentley Raceway and Cable Management
      • Working from home with AutoPLANT Modeler
      • Your Feedback is important to us!

     
     Questions about this article, topic, or product? Click here. 

    To Pick Reduced Half Coupling under Branch Table Automatically in OpenPlant Modeler

       
      Applies To 
       
      Product(s): OpenPlant Modeler
      Version(s): 08.11.09.XXX (SS5) & 08.11.11.87 (SS6)
      Environment:  Windows 7 (64 bit)
      Area:  OpenPlant Specification Generator
      Subarea:  Auto Branch Table - Half Coupling
      Original Author: Rahul Kumar, Bentley Product Advantage Group
       

    Overview

    To output branch lines with reduced half coupling in OpenPlant Modeler.

    Problem Description

    With the use of Specification generator, user wanted to update branch table with half coupling and wanted to get it picked up by branch table during placement in Modeler. By default only equal size half coupling gets placed. For Reduced size half coupling user need to perform below steps to get branch table for automatic placement.

    Steps to Resolve

    1. Launch Specification Generator. Open spec, say mA1_OPM here.

    2. From Main menu, go to “Tools”, and launch Branch Code editor. See below.



    3. Assign code “HC” for Half coupling from the code list. See below.



    4. From Main menu, go to ‘Tools’, and launch Branch Table editor.

    5. Assign HC code for Same size B/H and assign RT (reducing Tee) for dissimilar size B/H say DN100 XDN80, DN100XDN50 etc. See image below.



    6. Save spec.

    7. From Spec database folder, open mdb file through MS Access. And select “Auto_Tee” table. See image below.



    8. Rename the EC Class Name for PIPE_REDUCING_TEE_BRANCH to HALF_COUPLING. See image below.



    9. Launch OpenPlant Modeler.

    10. Select modified spec in standard preferences dialog. Place header of size DN100.

    11. Enable ‘Auto Branch Table’. Select reducing size DN50 and place it on header. See image below.



    12. It will pick the half coupling. See images below. 





    Still a Problem?

    If above problem still persist, then please create a Service Request and contact the Bentley Product Advantage group.  Please include a list of all relevant details to get in depth analysis for a solution or workaround. 

    See Also

    http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/13028.openplant-specification-generator

    Comments or Corrections?

    Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

    • OpenPlant Modeler
    • OPM
    • OpenPlant Specification Generator
    • 08.11.09.XXX
    • Half Coupling
    • 08.11.11.87
    • reducing Coupling
    • OPSG
    • Spec Gen
    • Share
    • History
    • More
    • Cancel
    • Rahul Kumar Created by Bentley Colleague Rahul Kumar
    • When: Wed, May 18 2016 11:23 AM
    • Rahul Kumar Last revision by Bentley Colleague Rahul Kumar
    • When: Wed, May 18 2016 11:24 AM
    • Revisions: 2
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies