Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
  • Welcome
  • Products
  • Support
  • About
  • More
  • Cancel
AutoPLANT | OpenPlant | PlantWise
  • Product Communities
  • More
AutoPLANT | OpenPlant | PlantWise
AutoPLANT | OpenPlant | PlantWise Wiki To Fix Missing Ports Information for PIPE_ELBOW_5_DEGREE in OpenPlant Modeler
    • Sign in
    • -AutoPLANT | Bentley Raceway and Cable Management | OpenPlant | PlantWise Wiki
      • -OpenPlant
        • +CONNECT Services - OpenPlant
        • +Example Configuration - CONNECT Edition
        • +Installations - OpenPlant CONNECT Edition Applications
        • +OpenPlant Download Links & Videos
        • OpenPlant Product Compatibility
        • +OpenPlant Modeler CONNECT
        • +OpenPlant PID CONNECT
        • +OpenPlant Isometrics Manager CONNECT
        • +OpenPlant Orthographics Manager CONNECT
        • +OpenPlant Support Engineering CONNECT
        • +OpenPlant Project Administrator CONNECT
        • +OpenPlant CONNECT Edition-PlantSight Integration
        • -OpenPlant Modeler v8i
          • +Component - OpenPlant Modeler
          • +Drawing Generation- OpenPlant Modeler
          • -Errors, Logs, Messages, Crashes - OpenPlant Modeler
            • "Failed to Find Cell Library for Diagram" Error While Placing Equipment
            • "No Component Found With Initial Selection From Specs" Appears While Placing Component
            • Attach OpenPlant Modeler Objects in ProSteel
            • Deleting User Data Files Local and Roaming
            • Duplicate Key Tags Message in OpenPlant Modeler
            • Graphics Issue- Distorted graphics- Display Graphics in OpenPlant Modeler
            • How To Fix "Unable to Load Schema For StressApp" Error in OpenPlant Modeler
            • Invalid Catalog Selected Issues in OpenPlant Specification Generator
            • Invalid Joint Error while Validating Joint for Custom Components
            • Line 241 Error-Launching OpenPlant Modeler
            • Property is Read Only Error in OpenPlant Modeler
            • Selected Spec is Incompatible With the Current Project
            • +Spec Validation Report Error: Some Properties in Spec Do Not Match in Component
            • Standard Preferences Dialog Disappeared from OpenPlant Modeler
            • StartUp Error-Launching OpenPlant Modeler
            • Structural Synchronizer Engine Not Found Message when Selecting Repository from Structural tab
            • Tap Port Connection On Blind Flange Placement Issue
            • To Fix Incorrect Property Update while using AutoMatch Option
            • To Fix Joint Connection Error While Modeling Component
            • To Fix Missing Ports Information for PIPE_ELBOW_5_DEGREE in OpenPlant Modeler
            • To Fix Pro Steel Models Referenced in OpenPlant using Object Enabler
            • To Fix Support Rotation Issue By Manual Rotation or By placing supports using OpenPlant Support Engineering .
            • To Fix Unhandled Exception Error while Launching Pipeline Manager in OpenPlant Modeler V8i
            • To Fix Unhandled Exception Error “Index was outside the bounds of the array”
            • Too Many Results (XXXX).Select this to see items in details
            • Unable to Delete Corrupt Component in OpenPlant Modeler
            • Unable to Find Catalog Issue in OpenPlant Specification Generator
            • Wafer Joint on Components with Different Facing and Rating Shows Error While Placement
          • +Import/Export- OpenPlant Modeler
          • +Installation - OpenPlant Modeler
          • OpenPlant HVAC-OpenPlant Modeler
          • OpenPlant Modeler [FAQ]
          • +OpenPlant Specification Generator
          • +ProjectWise - OpenPlant Modeler
          • +Properties - OpenPlant Modeler
          • +Release Notes - OpenPlant Modeler
          • +Schema - OpenPlant Modeler
          • +Settings/Attributes - OpenPlant Modeler
          • +Structural Modeling Components (SMC)- OpenPlant Modeler
          • +Tasks - OpenPlant Modeler
          • +Training - OpenPlant Modeler
        • +OpenPlant Isometrics Manager v8i
        • +OpenPlant Project Administrator v8i
        • +OpenPlant PID v8i
        • +OpenPlant Orthographics Manager v8i
        • +OpenPlant Support Engineering v8i
        • +OpenPlant ModelServer v8i
        • +OpenPlant Reporting v8i
        • How to Connect with Bentley Technical Support Team using Microsoft Teams
        • How to Connect with Bentley Technical Support Team using Microsoft Teams via Browser
      • +Bentley AutoPLANT
      • +Bentley Navigator
      • +Bentley PlantSpace
      • +Plant Project Tools
      • +Bentley Raceway and Cable Management
      • i-model Composition Service for S3D
      • Working from home with OpenPlant
      • Working from home with Bentley Raceway and Cable Management
      • Working from home with AutoPLANT Modeler
    • How to Associate the Specification Based on Service in OpenPlant Modeler Connect

     
     Questions about this article, topic, or product? Click here. 

    To Fix Missing Ports Information for PIPE_ELBOW_5_DEGREE in OpenPlant Modeler

       
      Applies To 
       
      Product(s): OpenPlant Modeler
      Version(s): 08.11.09.XXX/08.11.11.87
      Environment:  Windows 7 (64 bit)
      Area:  Component
      Subarea: 
      Original Author: Rahul Kumar, Bentley Product Advantage Group
       

    Overview

    In OpenPlant Modeler, to place a correct pipe elbow of 5 degree.

    Problem Description

    While modelling it has been observed that a fitting of PIPE_ ELBOW_5_DEGREE was not placed properly and its ports were missing under placement dialog box. See below a circular ring get placed along this fitting.

              

    Also check image below where ports were not present. 


              

    To ensure the correct placement, below are the steps mentioned to help user to achieve correct result. 

    Steps to Resolve

    1. In Class editor, Open ‘OpenPlant_3D.01.07.ecschema.xml’ and supplement it with below schemas

      “OpenPlant_3D_Supplemental_Modeling.01.04.ecschema.xml’ schema”
      “OpenPlant_3D_Supplemental_Information_3DComponent.01.07.ecschema”

      Above schema can be found by navigating below project path : 
      C:\ProgramData\Bentley\OpenPlantModelerV8i\WorkSpace\Projects\ OPModeler_Metric\DataSet\Schemas

    2. Navigate to desired class say PIPE_ ELBOW_5_DEGREE.

    3. Add Custom attribute (CA) “Component Ports information” to it.

      1. To add it, go to other class which contains the same custom attribute. Say PIPE_ ELBOW_30_DEGREE

      2. Right Click on it, go to Custom Attribute->Copy. 



      3. Select Component Ports Information CA and pull it down to copy. 



        Note – Please check the correct location of custom attribute as shown above. 

    4. Navigate to class PIPE_ELBOW_5_DEGREE, right click on it-> Custom Attribute->Paste. 

    5. Save & Close Schema.

    6. Launch OpenPlant Modeler.

    7. Place Elbow from Piping tab option. 



      Note – Make sure this class is present in your spec to get it available in OpenPlant Modeler
    8. Verify results. See image below. 


    Still A Problem?

    If above problem still persist, then please create a Service Request and contact Bentley Product Advantage group along with the list of all relevant details to get in depth analysis and for possible solution or workarounds. 

    See Also

    http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/20661.errors-logs-messages-crashes-openplant-modeler

    Comments or Corrections?

    Bentley's Product advantage Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

    • OpenPlant Modeler
    • OPM
    • PIPE_ELBOW_5_DEGREE
    • 08.11.09.XXX
    • placement
    • Ports
    • 08.11.11.87
    • Component Ports Information
    • schema
    • Share
    • History
    • More
    • Cancel
    • Rahul Kumar Created by Bentley Colleague Rahul Kumar
    • When: Fri, Jun 10 2016 6:30 AM
    • Rahul Kumar Last revision by Bentley Colleague Rahul Kumar
    • When: Fri, Jun 10 2016 6:31 AM
    • Revisions: 2
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2021 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies