To fix “Structural Modeling Components Initialization Error” in OpenPlant Modeler.
With latest version from 08.11.11.87 & above, there is a new tab called “Structural”. While selecting “Structural” option, it sometimes gives below message as “Structural Modeling Components Initialization Error” along with below details. See image below.
See Message below: The structural Property Catalog could not be initialized. This is a serious error and prevents the structural Modeling Components tools from being properly initialized.The SPC server may need to be restarted. If restarting your session does not resolve the issue, please check that the ‘Bentley Property Catalog Service’ is running under Windows Services. You may need to manually start the service or reboot your computer.
The SPC Connect returned a null CatalogManager.
This is happening because of missing SpcServer which may not have installed in system. User may download it from the Bentley Downloads folder which appears while installing OpenPlant Modeler in the system. See below step to resolve this issue.
If above problem still persist, then please create a Service Request and contact Bentley Product Advantage group along with the list of all relevant details to get in depth analysis and for possible solution or workarounds.