User get below error while synchronizing database to drawing. This error message appears only when equipment like Filter Press, Flare Tower, Chimney etc. are present in the drawing. Below is the full text of error message which appears in message center.LOG_ERROR - Bentley.Plant.ModelingFramework.SQLPluginAdapter - Synchronization stopped because of error: 'ExecuteOperations has fatally terminated because of the following exception: ECInstance {SERVICE_IS_RELATED_TO_EQUIPMENT(VG.0000003279)} belongs to the ECSchema {ECSchema: PlantProjectSchema.01.04} which is not supported in this connection: TEST001.dgn'. Additional Details (If Available): 'ECInstance {SERVICE_IS_RELATED_TO_EQUIPMENT(VG.0000003279)} belongs to the ECSchema {ECSchema: PlantProjectSchema.01.04} which is not supported in this connection: TEST001.dgn'
This error message is caused by duplicate class mappings in the mapping schema. Duplicate mapping is detected by a Key-in command 'pid plantproject detectduplicatemapping' as shown below:
This key-in command opens up the dialog showing classes having duplicate mappings.
Classes CONTINUOUS_SAND_FILTER and FILTER_PRESS are mapped to 'AT_EQUIP' tag type as shown below.
CONTINUOUS_SAND_FILTER
FILTER_PRESS
If there is still some problem while trying to perform any operation against OpenPlant PID, then please create a Service Request and contact Bentley Product Advantage group along with the list of all relevant details to get in depth analysis and for possible solution or workarounds.
Bentley Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!