How to Add/Remove HVAC Component Classes in Grid Report


Applies To 
Product(s):OpenPlant Reporting
Version(s):08.11.09.XXX (SS5) & 08.11.11.XXX (SS6)
Environment: Windows 7/8.1/10 (64 bit)
Area: DGN Reporting
Subarea: HVAC
Original Author:Harpreet Singh, Bentley Product Advantage Group

Background

By default in OpenPlant Modeler, HVAC report doesn't include all the classes in it. User wanted to add Louvers and Grills into the report. We will need to add both classes in the report query.

Steps to Accomplish

  1. Open the model and go to OpenPlant Modeler > Tools > Reports.

  2. Expand HVAC Components node and select ALL as shown below.



  3. Click the ellipse button on the query field to open query dialog.



  4. In the query dialog, click Items to see items included in the current query.



  5. Check ON Drum Louvers in the list as shown below.



  6. Select the grill classes as highlighted in the picture below.



  7. Click OK and save the changes.

  8. Generate the report again to verify the result.

Comments or Corrections?