Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
  • Welcome
  • Products
  • Support
  • About
  • More
  • Cancel
OpenPlant | AutoPLANT
  • Product Communities
  • More
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki How to Add/Remove HVAC Component Classes in Grid Report
    • Sign in
    • -OpenPlant | AutoPLANT Wiki
      • -OpenPlant
        • +CONNECT Services - OpenPlant
        • +Example Configuration - CONNECT Edition
        • +Installations - OpenPlant CONNECT Edition Applications
        • +OpenPlant Download Links & Videos
        • OpenPlant Product Compatibility
        • +OpenPlant Modeler CONNECT
        • +OpenPlant PID CONNECT
        • +OpenPlant Isometrics Manager CONNECT
        • +OpenPlant Orthographics Manager CONNECT
        • +OpenPlant Support Engineering CONNECT
        • +OpenPlant Project Administrator CONNECT
        • +OpenPlant CONNECT Edition-PlantSight Integration
        • +OpenPlant Modeler v8i
        • +OpenPlant Isometrics Manager v8i
        • +OpenPlant Project Administrator v8i
        • +OpenPlant PID v8i
        • +OpenPlant Orthographics Manager v8i
        • +OpenPlant Support Engineering v8i
        • +OpenPlant ModelServer v8i
        • -OpenPlant Reporting v8i
          • Error "No default report template is defined for this report" Appears While Report Generation
          • How to Add/Remove HVAC Component Classes in Grid Report
          • How To Cascade Pipeline Properties to Bolt Report in OpenPlant Modeler
          • How to create Cable Tray Material GRID Report
          • How to Exclude Existing Components from OpenPlant Modeler Reports
          • How to Export Grid Reports in OpenPlant Modeler
          • How to Extract Reports for Multiple Component Class in OpenPlant Modeler
          • How to Generate Consolidated BOM for Components using Pivot Table
          • How to Include Equipment Origin in DGN reports
          • How to Include XYZ Coordinates in Reports for Piping Components
          • How to Insert Report into Drawing in OpenPlant Modeler
          • +How to Show Branch Diameter In Piping Reports
          • How to Show Nozzle Elevation in Report
          • To Add Pipe Allowances as Field Fit Length in Grid Report
          • To Create BOM for Single Pipeline Using Query Option in OpenPlant Modeler
          • To Generate Weld Quantity for Slip On Joints in Weld Reports
          • To Obtain Bend Angle For Pipe Bends/Mitered Bends in reports, Query by Piping Components
          • To Trim Piping BOM Reports Template Fields in OpenPlant Modeler
        • How to Connect with Bentley Technical Support Team using Microsoft Teams
        • How to Connect with Bentley Technical Support Team using Microsoft Teams via Browser
        • How to get list of installed applications/programs on Windows Machine using Command Prompt.
        • How to get list of Windows Updates installed on the machine using Command Prompt.
      • +Bentley AutoPLANT
      • +Bentley Navigator
      • +Bentley PlantSpace
      • +Plant Project Tools
      • +Bentley Raceway and Cable Management
      • i-model Composition Service for S3D
      • Working from home with OpenPlant
      • Working from home with Bentley Raceway and Cable Management
      • Working from home with AutoPLANT Modeler
      • Your Feedback is important to us!

     
     Questions about this article, topic, or product? Click here. 

    How to Add/Remove HVAC Component Classes in Grid Report

    Applies To 
    Product(s): OpenPlant Reporting
    Version(s): 08.11.09.XXX (SS5) & 08.11.11.XXX (SS6)
    Environment:  Windows 7/8.1/10 (64 bit)
    Area:  DGN Reporting
    Subarea:  HVAC
    Original Author: Harpreet Singh, Bentley Product Advantage Group

    Background

    By default in OpenPlant Modeler, HVAC report doesn't include all the classes in it. User wanted to add Louvers and Grills into the report. We will need to add both classes in the report query.

    Steps to Accomplish

    1. Open the model and go to OpenPlant Modeler > Tools > Reports.

    2. Expand HVAC Components node and select ALL as shown below.



    3. Click the ellipse button on the query field to open query dialog.



    4. In the query dialog, click Items to see items included in the current query.



    5. Check ON Drum Louvers in the list as shown below.



    6. Select the grill classes as highlighted in the picture below.



    7. Click OK and save the changes.

    8. Generate the report again to verify the result.

    Comments or Corrections?

    Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

    • OpenPlant Modeler
    • Grid
    • HVAC
    • Drum Louvers
    • query
    • 08.11.09.xxxx
    • Grills
    • components
    • Report
    • Share
    • History
    • More
    • Cancel
    • Harpreet Singh Created by Bentley Colleague Harpreet Singh
    • When: Wed, Jul 27 2016 6:18 AM
    • Harpreet Singh Last revision by Bentley Colleague Harpreet Singh
    • When: Tue, Dec 13 2016 8:31 AM
    • Revisions: 3
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2021 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies