Applies To
Product(s):
OpenPlant Orthographics Manager
Version(s):
08.11.11.87 (SS6)
Environment:
Windows 7/8.1/10 (64 bit)
Area:
Drawing Generation
Subarea:
Tagging
Original Author:
Faisal Khan, Bentley Product Advantage Group
To Avoid Tagging Issue in Localized OpenPlant Orthographics Manager Application.
In OpenPlant Orthographics Manager Localized Application, Component tagging was not appearing in output drawing,
In OpenPlant Orthographics Manager, Project settings are defined in settings ini file and comma is used as separator. Now for localized builds if user puts comma as Decimal Symbol in regional settings then tagging will not be shown in output file as well as user will observe issues while creating view arrangement definition (VAD) file.
If above problem still persist, then please create a Service Request and contact the Bentley Product Advantage group. Please include a list of all relevant details to get in depth analysis for a solution or workaround.
http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/30083.how-to-create-new-view-arrangement-definition-vad-file
http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/30252.how-to-generate-output-drawing-in-openplant-orthographics-manager
Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!