Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
OpenPlant | AutoPLANT
  • Product Communities
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki To Avoid Tagging Issue in Localized OpenPlant Orthographics Manager Application.
    • Sign In
    • -OpenPlant | AutoPLANT Wiki
      • -OpenPlant
        • +CONNECT Services - OpenPlant
        • +Example Configuration - CONNECT Edition
        • +Installations - OpenPlant CONNECT Edition Applications
        • +OpenPlant Download Links & Videos
        • OpenPlant Product Compatibility
        • +OpenPlant Modeler CONNECT
        • +OpenPlant PID CONNECT
        • +OpenPlant Isometrics Manager CONNECT
        • +OpenPlant Orthographics Manager CONNECT
        • +OpenPlant Support Engineering CONNECT
        • +OpenPlant Project Administrator CONNECT
        • +OpenPlant CONNECT Edition-PlantSight Integration
        • +OpenPlant Modeler v8i
        • +OpenPlant Isometrics Manager v8i
        • +OpenPlant Project Administrator v8i
        • +OpenPlant PID v8i
        • -OpenPlant Orthographics Manager v8i
          • Copy Models Option Does Not Copy files to Orthographics Manager Project
          • Equipment and Nozzle dimensions missing in the orthographic drawing
          • Errors, Logs, Messages, Crashes - OpenPlant Orthographics Manager
          • How to Add Multiple Settings for a Project
          • How to Add Multiple Views in a Single View Arrangement Definition File
          • How to Add Revisions in OpenPlant Orthographics Manager's Output Drawing
          • How to Change Co-ordinates in OpenPlant Orthographics Manager’s Output Drawing
          • How to Change Settings as Per VAD file
          • How to Checkin OpenPlant Orthographics Manager's Output Drawings into ProjectWise
          • How to control Insulation Representation in OpenPlant Orthographics Manager
          • How to Copy Existing OpenPlant Orthographics Manager Project
          • How to Copy Models from Network or Local Drive into OpenPlant Orthographics Manager's Project Folder
          • How to Copy Models From ProjectWise into OpenPlant Orthographics Manager's Project Folder
          • How to create new project in OpenPlant Orthographics Manager
          • How to Create New View Arrangement Definition (VAD) File
          • How to Customize Pipe Tag Data
          • How to Delete View(s) from View Arrangement Definition (VAD) File
          • How to Delete a View Arrangement Definition (VAD) File in OpenPlant Orthographics Manager
          • How to Delete Existing Project in OpenPlant Orthographics Manager
          • How to Delete Generated OpenPlant Orthographics Manager Output Drawing(s)
          • How to Delete Unwanted Setting in a Project
          • How to Edit Existing View Arrangement Definition (VAD) File
          • How to Export View Arrangement Definition File Data to Excel Sheet
          • How to Generate Output Drawing in OpenPlant Orthographics Manager
          • How to Generate Reports in OpenPlant Orthographics Manager
          • How to Get Iso View in OpenPlant Orthographics Manager
          • How to Import View Arrangement Definition file Data from Excel
          • +How to Modify Gap between Line Number and Elevation
          • How to Overwrite Already Placed Models in OpenPlant Orthographics Manager's Project Folder
          • How to Remove Characters from Valve Tag Number in OpenPlant Orthographics Manager' s Output
          • How to Rotate View in Existing View Arrangement Definition (VAD) File
          • How to Show Hidden Line Components in OpenPlant Orthographics Manager's Output Drawing
          • How to Show Nozzle Number as Tag in OpenPlant Orthographics Manager Output Drawing
          • How to Show Overall Outside Dimensions only in Output
          • How to Show Piping Elevation Symbols in OpenPlant Orthographics Manager’s Output Drawing
          • How to Turn off Outside Labels and Dimensions
          • Importing OpenPLANT Orthographics project
          • OpenPlant Orthographics Manager [FAQ]
          • +Settings-OpenPlant Orthographics Manager
          • To Avoid Tagging Issue in Localized OpenPlant Orthographics Manager Application.
          • To Move Drawing Tag in Output Drawing
        • +OpenPlant Support Engineering v8i
        • +OpenPlant ModelServer v8i
        • +OpenPlant Reporting v8i
        • How to Connect with Bentley Technical Support Team using Microsoft Teams
        • How to Connect with Bentley Technical Support Team using Microsoft Teams via Browser
        • How to get list of installed applications/programs on Windows Machine using Command Prompt.
        • How to get list of Windows Updates installed on the machine using Command Prompt.
        • How to Package WorkSpace to be Shareable to Users for OpenPlant Projects
        • How to find iModel.dgn file of another domain in PlantSight
      • +Bentley AutoPLANT
      • +Bentley Navigator
      • +Bentley PlantSpace
      • +Plant Project Tools
      • +Bentley Raceway and Cable Management
      • i-model Composition Service for S3D
      • Working from home with OpenPlant
      • Working from home with Bentley Raceway and Cable Management
      • Working from home with AutoPLANT Modeler
      • Your Feedback is important to us!

     
     Questions about this article, topic, or product? Click here. 

    To Avoid Tagging Issue in Localized OpenPlant Orthographics Manager Application.

    Applies To 

    Product(s):

    OpenPlant Orthographics Manager

    Version(s):

    08.11.11.87 (SS6)

    Environment: 

    Windows 7/8.1/10 (64 bit)

    Area: 

    Drawing Generation

    Subarea: 

    Tagging

    Original Author:

    Faisal Khan, Bentley Product Advantage Group

    Overview

    To Avoid Tagging Issue in Localized OpenPlant Orthographics Manager Application.

    Problem Description

    In OpenPlant Orthographics Manager Localized Application, Component tagging was not appearing in output drawing,

    Reason

    In OpenPlant Orthographics Manager, Project settings are defined in settings ini file and comma is used as separator. Now for localized builds if user puts comma as Decimal Symbol in regional settings then tagging will not be shown in output file as well as user will observe issues while creating view arrangement definition (VAD) file.



    Steps to Resolve

    1. Go to Region settings



    2. Select Additional settings



    3. Select “Decimal” as Decimal Symbol in Numbers tab of Customize Format dialog and press OK to dialog



    4. Launch OpenPlant Orthographics Manager and select a project



    5. Go to Drawing Generation – Generate



    6. Select a VAD (View Arrangement Data) Files by checking the box against the name



    7. Press “Generate Drawings” after selecting View Arrangement Data file and output file options



    8. Output file will be generated and tagging will be correctly shown in output

        

    Still a Problem?

    If above problem still persist, then please create a Service Request and contact the Bentley Product Advantage group.  Please include a list of all relevant details to get in depth analysis for a solution or workaround. 

    See Also 

    http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/30083.how-to-create-new-view-arrangement-definition-vad-file

    http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/30252.how-to-generate-output-drawing-in-openplant-orthographics-manager

    Comments or Corrections?

    Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!

    • OPOM
    • 08.11.11.87
    • OpenPlant Orthographics Manager
    • tagging
    • localization
    • Share
    • History
    • More
    • Cancel
    • Faisal Khan Created by Bentley Colleague Faisal Khan
    • When: Thu, Aug 11 2016 12:36 PM
    • Revisions: 1
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies