Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
OpenPlant | AutoPLANT
  • Product Communities
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki How to Show Nozzle Number as Tag in OpenPlant Orthographics Manager Output Drawing
    • Sign In
    • -OpenPlant | AutoPLANT Wiki
      • -OpenPlant
        • +CONNECT Services - OpenPlant
        • +Example Configuration - CONNECT Edition
        • +Installations - OpenPlant CONNECT Edition Applications
        • +OpenPlant Download Links & Videos
        • OpenPlant Product Compatibility
        • +OpenPlant Modeler CONNECT
        • +OpenPlant PID CONNECT
        • +OpenPlant Isometrics Manager CONNECT
        • +OpenPlant Orthographics Manager CONNECT
        • +OpenPlant Support Engineering CONNECT
        • +OpenPlant Project Administrator CONNECT
        • +OpenPlant CONNECT Edition-PlantSight Integration
        • +OpenPlant Modeler v8i
        • +OpenPlant Isometrics Manager v8i
        • +OpenPlant Project Administrator v8i
        • +OpenPlant PID v8i
        • -OpenPlant Orthographics Manager v8i
          • Copy Models Option Does Not Copy files to Orthographics Manager Project
          • Equipment and Nozzle dimensions missing in the orthographic drawing
          • Errors, Logs, Messages, Crashes - OpenPlant Orthographics Manager
          • How to Add Multiple Settings for a Project
          • How to Add Multiple Views in a Single View Arrangement Definition File
          • How to Add Revisions in OpenPlant Orthographics Manager's Output Drawing
          • How to Change Co-ordinates in OpenPlant Orthographics Manager’s Output Drawing
          • How to Change Settings as Per VAD file
          • How to Checkin OpenPlant Orthographics Manager's Output Drawings into ProjectWise
          • How to control Insulation Representation in OpenPlant Orthographics Manager
          • How to Copy Existing OpenPlant Orthographics Manager Project
          • How to Copy Models from Network or Local Drive into OpenPlant Orthographics Manager's Project Folder
          • How to Copy Models From ProjectWise into OpenPlant Orthographics Manager's Project Folder
          • How to create new project in OpenPlant Orthographics Manager
          • How to Create New View Arrangement Definition (VAD) File
          • How to Customize Pipe Tag Data
          • How to Delete View(s) from View Arrangement Definition (VAD) File
          • How to Delete a View Arrangement Definition (VAD) File in OpenPlant Orthographics Manager
          • How to Delete Existing Project in OpenPlant Orthographics Manager
          • How to Delete Generated OpenPlant Orthographics Manager Output Drawing(s)
          • How to Delete Unwanted Setting in a Project
          • How to Edit Existing View Arrangement Definition (VAD) File
          • How to Export View Arrangement Definition File Data to Excel Sheet
          • How to Generate Output Drawing in OpenPlant Orthographics Manager
          • How to Generate Reports in OpenPlant Orthographics Manager
          • How to Get Iso View in OpenPlant Orthographics Manager
          • How to Import View Arrangement Definition file Data from Excel
          • +How to Modify Gap between Line Number and Elevation
          • How to Overwrite Already Placed Models in OpenPlant Orthographics Manager's Project Folder
          • How to Remove Characters from Valve Tag Number in OpenPlant Orthographics Manager' s Output
          • How to Rotate View in Existing View Arrangement Definition (VAD) File
          • How to Show Hidden Line Components in OpenPlant Orthographics Manager's Output Drawing
          • How to Show Nozzle Number as Tag in OpenPlant Orthographics Manager Output Drawing
          • How to Show Overall Outside Dimensions only in Output
          • How to Show Piping Elevation Symbols in OpenPlant Orthographics Manager’s Output Drawing
          • How to Turn off Outside Labels and Dimensions
          • Importing OpenPLANT Orthographics project
          • OpenPlant Orthographics Manager [FAQ]
          • +Settings-OpenPlant Orthographics Manager
          • To Avoid Tagging Issue in Localized OpenPlant Orthographics Manager Application.
          • To Move Drawing Tag in Output Drawing
        • +OpenPlant Support Engineering v8i
        • +OpenPlant ModelServer v8i
        • +OpenPlant Reporting v8i
        • How to Connect with Bentley Technical Support Team using Microsoft Teams
        • How to Connect with Bentley Technical Support Team using Microsoft Teams via Browser
        • How to get list of installed applications/programs on Windows Machine using Command Prompt.
        • How to get list of Windows Updates installed on the machine using Command Prompt.
        • How to Package WorkSpace to be Shareable to Users for OpenPlant Projects
        • How to find iModel.dgn file of another domain in PlantSight
      • +Bentley AutoPLANT
      • +Bentley Navigator
      • +Bentley PlantSpace
      • +Plant Project Tools
      • +Bentley Raceway and Cable Management
      • i-model Composition Service for S3D
      • Working from home with OpenPlant
      • Working from home with Bentley Raceway and Cable Management
      • Working from home with AutoPLANT Modeler
      • Your Feedback is important to us!

     
     Questions about this article, topic, or product? Click here. 

    How to Show Nozzle Number as Tag in OpenPlant Orthographics Manager Output Drawing

     

    Applies To 

    Product(s):

    OpenPlant Orthographics Manager

    Version(s):

    08.11.11.87 (SS6)

    Environment: 

    Windows 7/8.1/10 (64 bit)

    Area: 

    Drawing Generation

    Subarea: 

    Nozzle Tagging

    Original Author:

    Faisal Khan, Bentley Product Advantage Group

    To show nozzle number as tag in OpenPlant Orthographics Manager output drawing 

    Background

    In OpenPlant Orthographics Manager, Nozzle NAME is shown by default as nozzle tagging in output drawing. If Nozzle name is not set in DGN or imodel then nozzle tag will not be shown in output drawing. In most cases like in AutoPLANT nozzles, Nozzle Number set in DWG so in imodel. So if user wants to see Nozzle Number in OpenPlant Orthographics Manager output drawing then he needs to change Nozzle TagNumber value to Number in AnalyzeConfig.xml

    Steps to Accomplish 

    1. Launch OpenPlant Orthographics Manager and select a project say Sample Metric



    2. Go to Drawing Generation -- Generate



    3. Select a VAD file having Nozzles with Number set in DGN/imodel



    4. Press “Generate Drawings” to generate output file. It will show output file with nozzle tagged as “Nozzle”



    5. Now go to OpenPlant Orthographics Manager installed directory and open “AnalyzeConfig.xml” file in Notepad to edit i.e. if OpenPlant Orthographics Manager installed in Program Files (x86)
      “C:\Program Files (x86)\Bentley\OrthographicsManager V8i\OrthographicsManager\bin”



    6. Find “NOZZLE ECClassName”

    7. Change TagNumber value from “NAME” to “NUMBER”



    8. Save and close xml file

    9. Re-launch OpenPlant Orthographics Manager after the changings

    10. Go to Project Settings -- Annotations -- Equipment and Nozzles and make sure “Add prefix” and “Truncate equipment name” boxes are empty for Nozzle settings

    11. Go to Drawing Generation -- Generate

    12. Select a same VAD file having Nozzles with Number set in DGN/imodel

    13. Press “Generate Drawings” to generate output file



    14. Now it will show Number as no Nozzle tag in output

        

    See Also 

    http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/30083.how-to-create-new-view-arrangement-definition-vad-file

    http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/30252.how-to-generate-output-drawing-in-openplant-orthographics-manager 

    Still a Problem?

    If above problem still persist, then please create a Service Request and contact the Bentley Product Advantage group. Please include a list of all relevant details to get in depth analysis for a solution or workaround. 

    Comments or Corrections?

    Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!

    • Output Tagging
    • OPOM
    • Nozzle
    • 08.11.11.87
    • Nozzle Tagging
    • OpenPlant Orthgraphics Manager
    • Share
    • History
    • More
    • Cancel
    • Faisal Khan Created by Bentley Colleague Faisal Khan
    • When: Fri, Aug 12 2016 2:57 AM
    • Revisions: 1
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies