Applies To
Product(s):
OpenPlant Orthographics Manager
Version(s):
08.11.11.87 (SS6)
Environment:
Windows 7/8.1/10 (64 bit)
Area:
Drawing Generation
Subarea:
Nozzle Tagging
Original Author:
Faisal Khan, Bentley Product Advantage Group
To show nozzle number as tag in OpenPlant Orthographics Manager output drawing
In OpenPlant Orthographics Manager, Nozzle NAME is shown by default as nozzle tagging in output drawing. If Nozzle name is not set in DGN or imodel then nozzle tag will not be shown in output drawing. In most cases like in AutoPLANT nozzles, Nozzle Number set in DWG so in imodel. So if user wants to see Nozzle Number in OpenPlant Orthographics Manager output drawing then he needs to change Nozzle TagNumber value to Number in AnalyzeConfig.xml
http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/30083.how-to-create-new-view-arrangement-definition-vad-file
http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/30252.how-to-generate-output-drawing-in-openplant-orthographics-manager
If above problem still persist, then please create a Service Request and contact the Bentley Product Advantage group. Please include a list of all relevant details to get in depth analysis for a solution or workaround.
Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!