You are currently reviewing an older revision of this page.
Applies To
Product(s):
OpenPlant Orthographics Manager
Version(s):
08.11.11.87 (SS6)
Environment:
Windows 7/8.1/10 (64 bit)
Area:
Drawing Generation
Subarea:
Original Author:
Faisal Khan, Bentley Product Advantage Group
To Show Both Single and Double Pipe Lines in OpenPlant Orthographics Output Drawing
In OpenPlant Orthographics Manager, if a model contains number of pipelines of different sizes and user wants to see some pipe lines as Single Pipeline and some a Double Pipeline then it is possible for user to see in same OpenPlant Orthographics Manager Output drawing.
http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/30083.how-to-create-new-view-arrangement-definition-vad-file
http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/30252.how-to-generate-output-drawing-in-openplant-orthographics-manager
OpenPlant Orthographics Manager Help
Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!