Applies To | |
Product(s): | OpenPlant Modeler |
Version(s): |
8.11.11.87/96 (SS6) & above
|
Environment: | Windows 7 (64-bit) | Windows 10 |
Area: | OpenPlant Isometrics Manager |
Subarea: | Customization |
Original Author: | Deepak Singh, Bentley Product advantage Group
|
In OpenPlant Isometric Manager, to hide the SIZE 1 & SIZE 2 for Bolts from Bill of Material
Background
In isometric output, requirement is to show quantity & hide SIZE 1 and SIZE 2 for bolts in Bill of Material.
Steps to Accomplish
- Launch OpenPlant Isometrics Manager.
- Select your particular project here metric project.
- From OpenPlant Isometrics Manager click on configuration tool.
- From Configuration Window, select your desired style here IFC style.
- Click on Advanced option and select Open Report Definition.
- Scroll down and under FLD report make changes as shown.
- Below FLD report write a new REPORT for BOLT as shown.
- Under COMBI report make changes as shown.
- Save the report definition file.
- Generate isometric and verify the result.
- Notice that only quantity is showing for Bolts, SIZE 1 & SIZE 2 are hidden as per requirement.
See Also
communities.bentley.com/.../30427.how-to-convert-autoplant-pdw-catalog-to-openplant-modeler-format-using-exchange-option-of-specgen
Comments & Corrections?
Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!