To Discuss Various Labels Related issues in OpenPlant Isometrics Manager


Applies To 
Product(s):OpenPlant Isometrics Manager
Version(s):08.11.09.xxx (SS5)
Environment: Windows 7 (64 bit) & others
Area: Settings/Attributes
Subarea: 
Original Author: Rahul Kumar, Bentley Product Advantage Group

Overview

To Discuss Various Labels issues in OpenPlant Isometrics Manager. 

Problem Description

In OpenPlant Isometrics Manager, Labels customization and output in Isometrics drawing can be done by customization. In this section various use cases can be listed to assist user to proceed in their projects. This can be realized in both AutoPLANT Modeler-OpenPlant Isometrics Manager & OpenPlant Modeler-OpenPlant Isometrics Manager.

OpenPlant Modeler-OpenPlant Isometrics Manager

In case of Butterfly valves, finding PARTID is difficult. PARTID in BOM for Butterfly valve appears to be different and display as, say 5. 

Reason

Since Butterfly valve act like a wafer valve, part ID falls under label indexing for fasteners and it displays with a prefix W. Hence appear as W5. See image below. 

Steps to Resolve

With latest release of OpenPlant Isometrics Manager SS6, it displays the labels separately and without prefix to avoid confusion. User may install latest OpenPlant Isometrics Manager SS6 and verify its results. See isometrics extracted with latest version. 

Still a Problem?

If above problem still persist, then please create a Service Request and contact the Bentley Product Advantage group.  Please include a list of all relevant details to get in depth analysis for a solution or workaround. 