You are currently reviewing an older revision of this page.
To Discuss Various Labels issues in OpenPlant Isometrics Manager.
In OpenPlant Isometrics Manager, Labels customization and output in Isometrics drawing can be done by customization. In this section various use cases can be listed to assist user to proceed in their projects. This can be realized in both AutoPLANT Modeler-OpenPlant Isometrics Manager & OpenPlant Modeler-OpenPlant Isometrics Manager.
In case of Butterfly valves, finding PARTID is difficult. PARTID in BOM for Butterfly valve appears to be different and display as, say 5.
Since Butterfly valve act like a wafer valve, part ID falls under label indexing for fasteners and it displays with a prefix W. Hence appear as W5. See image below.
With latest release of OpenPlant Isometrics Manager SS6, it displays the labels separately and without prefix to avoid confusion. User may install latest OpenPlant Isometrics Manager SS6 and verify its results. See isometrics extracted with latest version.
If above problem still persist, then please create a Service Request and contact the Bentley Product Advantage group. Please include a list of all relevant details to get in depth analysis for a solution or workaround.
http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/13393.settingsattributes-openplant-isometrics-manager
Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!