<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>How to Assign Symbology Based on Insulation Material Using Named Expression</title><link>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/31762/how-to-assign-symbology-based-on-insulation-material-using-named-expression</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>How to Assign Symbology Based on Insulation Material Using Named Expression</title><link>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/31762/how-to-assign-symbology-based-on-insulation-material-using-named-expression</link><pubDate>Mon, 21 Nov 2016 13:11:35 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:939dd45e-a32d-41a0-b406-4a9aeb9ab69d</guid><dc:creator>Rahul Kumar</dc:creator><comments>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/31762/how-to-assign-symbology-based-on-insulation-material-using-named-expression#comments</comments><description>Current Revision posted to OpenPlant | AutoPLANT Wiki by Rahul Kumar on 11/21/2016 1:11:35 PM&lt;br /&gt;
&lt;h1&gt;&lt;b&gt;&lt;img src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" height="60" alt=" " /&gt;&lt;/b&gt;&lt;/h1&gt;
&lt;div class="content-scrollable-wrapper"&gt;
&lt;table border="0" style="border-color:#dce5f0;border-width:0px;background-color:#dce5f0;width:500px;border-style:solid;"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Applies To&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenPlant Modeler&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.11.09.XXX (SS5) | 08.11.11.XX (SS6)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Windows 7/8.1/10 (64 bit)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Settings/Attributes&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;-&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Rahul Kumar, Bentley Product Advantage Group&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;To set Insulation Symbology Based on Insulation Material using Named expression in OpenPlant Modeler.&amp;nbsp;&lt;/p&gt;
&lt;h3&gt;Background&lt;/h3&gt;
&lt;p&gt;OpenPlant component symbology is managed in the typical MicroStation fashion. It is controlled through a combination of Named Expressions (used to read attributes and assign the Element Templates accordingly) and Element Templates (where symbology is defined for the elements identified by the Named Expression). For defining symbology based on Insulation Material, below are the steps to follow.&amp;nbsp;&lt;/p&gt;
&lt;h3&gt;Steps to Accomplish&lt;/h3&gt;
&lt;ol&gt;
&lt;li&gt;All of component symbology settings are usually set in OPmodeler.dgnlib file, located in WorkSpace\Projects\%project_name%\DataSet\Dgnlibs folder. Navigate to mentioned path to open the file.&lt;/li&gt;
&lt;li&gt;In menu select Element -&amp;gt; &lt;strong&gt;Element Templates.&lt;br /&gt;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/4162.7.jpg"&gt;&lt;img src="/resized-image/__size/540x0/__key/communityserver-wikis-components-files/00-00-00-00-43/4162.7.jpg" width="233" height="233" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;&lt;/strong&gt;&lt;/li&gt;
&lt;li&gt;Browse to &lt;strong&gt;OpenPlan&lt;/strong&gt;t -&amp;gt; &lt;strong&gt;Piping&lt;/strong&gt; section.&lt;/li&gt;
&lt;li&gt;Create Symbology for Insulation Material&lt;/li&gt;
&lt;li&gt;Set symbology as per requirement. See below has been set for few existing Services.&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;For Insulation Material &amp;ndash; Calcium Silicate:&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/2845.1.jpg"&gt;&lt;img src="/resized-image/__size/540x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2845.1.jpg" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;For Insulation Material &amp;ndash; Fiber Glass:&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/3750.2.jpg"&gt;&lt;img src="/resized-image/__size/540x0/__key/communityserver-wikis-components-files/00-00-00-00-43/3750.2.jpg" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;b&gt;Note &amp;ndash; &lt;/b&gt;&lt;i&gt;Similarly for other Insulation Material, symbology can be defined. Ensure that Insulation material should defined under correct&amp;nbsp;hierarchy, i.e under &lt;strong&gt;OpenPlant&lt;/strong&gt; &amp;gt; &lt;strong&gt;Piping&lt;/strong&gt;.&amp;nbsp;&lt;/i&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;In Main menu open &lt;b&gt;Utilities&lt;/b&gt; -&amp;gt; &lt;b&gt;Named Expressions&lt;/b&gt;.&amp;nbsp;&lt;br /&gt;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/2311.3.jpg"&gt;&lt;img src="/resized-image/__size/640x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2311.3.jpg" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;For Pipeline Insulation, it is requires update for &lt;b&gt;OP_SYMBOLOGY_PIPING_INSULATION&lt;/b&gt;&lt;br /&gt; &lt;br /&gt; OP_SYMBOLOGY_PIPING_INSULATION:&lt;br /&gt; &lt;code&gt;&lt;strong&gt;&amp;quot;BY_LEVEL_AND_TEMPLATE:&amp;quot; &amp;amp; PIPELINE.NAME &amp;amp; &amp;quot;:OpenPlant\Piping\&amp;quot; &amp;amp; OPITEM.INSULATION &amp;amp; &amp;quot;:Insulation&amp;quot;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/5852.6.jpg"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-43/5852.6.jpg" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;/code&gt;&lt;/li&gt;
&lt;li&gt;Save Expression and close the dialog box.&lt;/li&gt;
&lt;li&gt;Save and close the DGNLIB file.&lt;/li&gt;
&lt;li&gt;Launch OpenPlant Modeler and verify results with working DGN file.&amp;nbsp;&lt;br /&gt;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/4403.4.jpg"&gt;&lt;img src="/resized-image/__size/240x0/__key/communityserver-wikis-components-files/00-00-00-00-43/4403.4.jpg" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/6888.5.jpg"&gt;&lt;img src="/resized-image/__size/240x0/__key/communityserver-wikis-components-files/00-00-00-00-43/6888.5.jpg" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;h3&gt;See Also&lt;/h3&gt;
&lt;p&gt;&lt;a href="http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/4870.named-expressions-managing-component-symbology-in-openplant-modeler"&gt;communities.bentley.com/.../4870.named-expressions-managing-component-symbology-in-openplant-modeler&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Comments or Corrections?&lt;/h3&gt;
&lt;p&gt;Bentley&amp;#39;s Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;
&lt;/div&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: OpenPlant Modeler, OPM, insulation, 08.11.11.87&lt;/div&gt;
</description></item><item><title>How to Assign Symbology Based on Insulation Material Using Named Expression</title><link>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/31762/how-to-assign-symbology-based-on-insulation-material-using-named-expression/revision/1</link><pubDate>Fri, 18 Nov 2016 12:36:59 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:939dd45e-a32d-41a0-b406-4a9aeb9ab69d</guid><dc:creator>Rahul Kumar</dc:creator><comments>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/31762/how-to-assign-symbology-based-on-insulation-material-using-named-expression#comments</comments><description>Revision 1 posted to OpenPlant | AutoPLANT Wiki by Rahul Kumar on 11/18/2016 12:36:59 PM&lt;br /&gt;
&lt;h1&gt;&lt;b&gt;&lt;img src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" height="60" alt=" " /&gt;&lt;/b&gt;&lt;/h1&gt;
&lt;div class="content-scrollable-wrapper"&gt;
&lt;table border="0" style="border-color:#dce5f0;border-width:0px;background-color:#dce5f0;width:500px;border-style:solid;"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Applies To&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenPlant Modeler&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.11.09.XXX (SS5) | 08.11.11.XX (SS6)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Environment:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Windows 7/8.1/10 (64 bit)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Area:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Settings/Attributes&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;-&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Rahul Kumar, Bentley Product Advantage Group&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;To set Insulation Symbology Based on Insulation Material using Named expression in OpenPlant Modeler.&amp;nbsp;&lt;/p&gt;
&lt;h3&gt;Background&lt;/h3&gt;
&lt;p&gt;OpenPlant component symbology is managed in the typical MicroStation fashion. It is controlled through a combination of Named Expressions (used to read attributes and assign the Element Templates accordingly) and Element Templates (where symbology is defined for the elements identified by the Named Expression). For defining symbology based on Insulation Material, below are the steps to follow.&amp;nbsp;&lt;/p&gt;
&lt;h3&gt;Steps to Accomplish&lt;/h3&gt;
&lt;ol&gt;
&lt;li&gt;All of component symbology settings are usually set in OPmodeler.dgnlib file, located in WorkSpace\Projects\%project_name%\DataSet\Dgnlibs folder. Navigate to mentioned path to open the file.&lt;/li&gt;
&lt;li&gt;In menu select Element -&amp;gt; &lt;strong&gt;Element Templates.&lt;br /&gt;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/4162.7.jpg"&gt;&lt;img src="/resized-image/__size/540x0/__key/communityserver-wikis-components-files/00-00-00-00-43/4162.7.jpg" width="233" height="233" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;&lt;/strong&gt;&lt;/li&gt;
&lt;li&gt;Browse to &lt;strong&gt;OpenPlan&lt;/strong&gt;t -&amp;gt; &lt;strong&gt;Piping&lt;/strong&gt; section.&lt;/li&gt;
&lt;li&gt;Create Symbology for Insulation Material&lt;/li&gt;
&lt;li&gt;Set symbology as per requirement. See below has been set for few existing Services.&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;For Insulation Material &amp;ndash; Calcium Silicate:&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/2845.1.jpg"&gt;&lt;img src="/resized-image/__size/540x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2845.1.jpg" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;For Insulation Material &amp;ndash; Fiber Glass:&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/3750.2.jpg"&gt;&lt;img src="/resized-image/__size/540x0/__key/communityserver-wikis-components-files/00-00-00-00-43/3750.2.jpg" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;b&gt;Note &amp;ndash; &lt;/b&gt;&lt;i&gt;Similarly for other Insulation Material, symbology can be defined.&lt;/i&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;In Main menu open &lt;b&gt;Utilities&lt;/b&gt; -&amp;gt; &lt;b&gt;Named Expressions&lt;/b&gt;.&amp;nbsp;&lt;br /&gt;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/2311.3.jpg"&gt;&lt;img src="/resized-image/__size/640x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2311.3.jpg" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;For Pipeline Insulation, it is requires update for &lt;b&gt;OP_SYMBOLOGY_PIPING_INSULATION&lt;/b&gt;&lt;br /&gt; &lt;br /&gt; OP_SYMBOLOGY_PIPING_INSULATION:&lt;br /&gt; &lt;code&gt;&lt;strong&gt;&amp;quot;BY_LEVEL_AND_TEMPLATE:&amp;quot; &amp;amp; PIPELINE.NAME &amp;amp; &amp;quot;:OpenPlant\Piping\&amp;quot; &amp;amp; OPITEM.INSULATION &amp;amp; &amp;quot;:Insulation&amp;quot;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/5852.6.jpg"&gt;&lt;img src="/resized-image/__size/940x0/__key/communityserver-wikis-components-files/00-00-00-00-43/5852.6.jpg" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;/code&gt;&lt;/li&gt;
&lt;li&gt;Save Expression and close the dialog box.&lt;/li&gt;
&lt;li&gt;Save and close the DGNLIB file.&lt;/li&gt;
&lt;li&gt;Launch OpenPlant Modeler and verify results with working DGN file.&amp;nbsp;&lt;br /&gt;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/4403.4.jpg"&gt;&lt;img src="/resized-image/__size/240x0/__key/communityserver-wikis-components-files/00-00-00-00-43/4403.4.jpg" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;a href="/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/6888.5.jpg"&gt;&lt;img src="/resized-image/__size/240x0/__key/communityserver-wikis-components-files/00-00-00-00-43/6888.5.jpg" alt=" " /&gt;&lt;/a&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;h3&gt;See Also&lt;/h3&gt;
&lt;p&gt;&lt;a href="http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/4870.named-expressions-managing-component-symbology-in-openplant-modeler"&gt;communities.bentley.com/.../4870.named-expressions-managing-component-symbology-in-openplant-modeler&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;Comments or Corrections?&lt;/h3&gt;
&lt;p&gt;Bentley&amp;#39;s Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this &amp;quot;Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;
&lt;/div&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: OpenPlant Modeler, OPM, insulation, 08.11.11.87&lt;/div&gt;