OpenPlant Modeler configuration variable list for the user to use it inside the working project to allow them to customize it as per requirement. Check various lists of use. This can be used at various stage of work. Some variable examples can be found in existing wiki articles which can also be searched using the keywords of this configuration.
Below is a list of available configuration variables which control various OpenPlant functions and procedures.
Config Variable
Value
Definition
OPM_SUPPORTED_MIN_ANGLE
1
Defines the min angle for placement of pipe bends and trimmed elbows
OPM_SUPPORTED_ANGLES
0,45,60,90
List of angles supported for component placement in autofitting
OPM_SUPPORTED_ANGLE_TOLERANCE
2.5
Tolerance for exactly matching the bend angles
OPM_MISALIGNMENT_ALLOWANCE
10
The OPM_MISALIGNMENT_ALLOWANCE variable is an angular tolerance value for allowing the AutoFitting routine to dynamically place a rigid fitting at a non-exact angle when the user-interface toggle Allow Misaligned Fittings is ON. This toggle is useful for a dynamically placed sloped pipeline to place rigid, though slightly misaligned, branch fittings and bends. The angular value is applied (+/-) to both sides of the dynamically misaligned connection.
OPM_AUTOFITTING_TRIM_STOCK_ANGLES
90;45
Default elbow angle types for trimmed elbows supported in AutoFitting
OPM_AUTOFITTING_ELBOW_TYPES
LongRadius; ShortRadius; 3R
List of elbow types supported by Auto fitting
OPM_HVAC_AUTOFITTING_GENERICCOMPONENT
To place generic/custom component if we dont find that component in spec
OPM_MIN_ANGLE_FOR_MITERED_ELBOWS
30
Default Min angle limit for mitered elbows
OPM_MAX_ANGLE_FOR_MITERED_ELBOWS
90
Default Max angle limit for mitered elbows
OPM_REPLACE_BEND_KEEP_BEND_RADIUS
When value set to 1, this variable will preserve the pipe bend radius or pipe bend radius factor on existing bend components during the Change Size/Change Spec function.
OPM_QUICK_REPLACE
Enables to disables the appearance of the replace component option on the right click menu. A value of 0 means no menu pick. 1 means to show the menu pick
OPM_HOOKUP_TOOL_ANGLES_FILE
${OPM_USER}/HookupAngles.xml
hookup tool angle xml location
OPM_HEAL_ON_DELETE
Enable or disable the pipe healing on component deletion
OPM_HEAL_MAX_DELETED
Max no. of component deletion to invoke the pipe healing
OPM_GEN_BRANCH_MIN_ANGLE_DIFF
45
Min allowable angle between Main/Run and Branch ot avoid the overlapping cylinders
OPM_ATTRIBUTESTOCHECK
NOMINAL_DIAMETER
List of mandatory properties that should be matched between the mating components
Description
OPM_USE_ATTRIBUTESTOCHECK_VAR_FOR_REPLACEMENT
0
Is used by replace command to refine replacement list; if the variable value is set to 1, replace command will use all properties defined by OPM_ATTRIBUTESTOCHECK and End Preperation property to filter out components.
OPM_TRAY_OPTIONAL_ATTRIBUTESTOCHECK
SPECIFICATION
list of optional properties that should be matched between mating components
OPM_TRAY_ATTRIBUTESTOCHECK
NOMINAL_WIDTH;NOMINAL_HEIGHT
OPM_QUERY_BOLTS_WITH_IGNORE_LENGTH
Ignore Bolt Length for getting spec records
OPM_AUTO_BOLT_SELECTION
Suppresses the Spec Selection dialog and selects bolt with a length closest to the defined minimum length.
OPM_OPTIONAL_ATTRIBUTESTOCHECK
OPM_OPENEND_SEARCH_FACTOR
0.5
is factor multiplied to Nominal Diameter to search for open ports near a given port in connectivity checker.
OPM_MATCH_PROPERTY_MAP_RATING
CL150;CL125|CL250;CL300|PN25;
PN40|PN10;PN16
List of compatible rating values for mating components
OPM_MATCH_PROPERTY_MAP_FACING
C;D|E;F
Pair of facing values are compatible with each other
OPM_FLANGE_JOINT_TOLERANCE
0.25
Define the max gap length between the matting flanges in PSDS or PDx dgn to consider it for a flange joint
OPM_DEFAULT_WELD_TYPE
SHOP
Default weld type to be used for component connection
OPM_DEFAULT_WELD_SPHERE_RADIUS
0.2
Size of the weld symbol
OPM_DEFAULT_WELD_LENGTH
default weld gap
OPM_CONNECTIVITY_TOLERANCE
0.05
Allowable gap between the mating ports for a valid joint between them
OPM_ALIGNMENT_TOLERANCE
Angular tolerance in Degrees between the mating port
Also Check Help File Menu
Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!