You are currently reviewing an older revision of this page.
In OpenPlant Isometrics Manager, Cut list in Multiple Columns.
With latest release of OpenPlant Isometrics Manager, cut list report can overflow in multiple column. In previous version, cut list extends in one table only and hence reports a long vertical list which sometimes overlaps above SHOP/FIELD Reporting. See below cut list BOM when produced using previous version. There are total 11 pipe cut pieces.
Now user can reduce its entries from one column and display it in second column of table. It should work in context with both AutoPLANT Modeler – OpenPlant Isometrics Manager & OpenPlant Modeler-OpenPlant Isometrics Manager. See below settings to describe the situation.
d. Similarly, copy another lines just above the previously placed copied lines & properties as shown below.
e. Enter header name as CUT LIST, copy the existing properties & past it to 82 mm right as shown below.
f. Extend lines up to newly created header of cut list as shown
g. Once defined do save setting.Created header for cut list will look like as shown below. h. For exact width of property, modify column spacing of CUT report in your particular report definition file as shown below.
REPORT = CUT INCLUDE = IE_TYPE=CT_PIPE|CT_BEND COLUMN = 8:C:CUTID COLUMN = 9:R:SIZE1 COLUMN = 21:R:QUANTITY COLUMN = 3:R: COLUMN = 38:R:IE_DESCRIPT GROUP = CUTID SORT = CUTID NODE = 61 MAX-LINES = 8END
h. Save all the settings & create an isometric drawing to verify the results as shown below.
http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/12642.configuring-the-bom-and-reports
Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!