To Create BOM for Single Pipeline Using Query Option in OpenPlant Modeler


Applies To 
Product(s):OpenPlant Reporting
Version(s):08.11.09.XXX (SS5) | 08.11.11.XX (SS6)
Environment: Windows 7/8.1/10 (64 bit)
Area: OpenPlant Reporting
Subarea: DGN Reporting
Original Author:Rahul Kumar, Bentley Product Advantage Group

Overview

In OpenPlant Modeler, to create BOM for single Pipeline selection. 

Problem Description

User requirement was to create a single line report and to generate inside Grid report using OpenPlant Modeler. Below are the steps to achieve desired result. 

Steps to Resolve

  1. Launch OpenPlant Modeler, Select Project unit. Say Metric here.
  2. Go to OpenPlant Modeler>Tools>Item Reports.



  3. From Piping>Piping Component, select BOM type BOM by Line Number. 
  4. Right click on it, Select ‘Edit’. 



  5. Click on browse option for Querying. 



  6. Use Where option to query for single Pipeline.
  7. Pick Line number option and enter the pipeline required to be used in reports. See image below.



  8. Add to search for performing query.
  9. Click on OK and generate report to verify results. See image below. 

Still a Problem?

If above problem still persist, then please create a Service Request and contact the Bentley Product Advantage group.  Please include a list of all relevant details to get in depth analysis for a solution or workaround. 

See Also

communities.bentley.com/.../4352.openplant-reporting

Comments or Corrections?

Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!