Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
OpenPlant | AutoPLANT
  • Product Communities
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki Error: XCHG0000: Failed to initialize OpenPlant Isometric data converter 1
    • Sign In
    • -OpenPlant | AutoPLANT Wiki
      • -OpenPlant
        • +CONNECT Services - OpenPlant
        • +Example Configuration - CONNECT Edition
        • +Installations - OpenPlant CONNECT Edition Applications
        • +OpenPlant Download Links & Videos
        • OpenPlant Product Compatibility
        • +OpenPlant Modeler CONNECT
        • +OpenPlant PID CONNECT
        • +OpenPlant Isometrics Manager CONNECT
        • +OpenPlant Orthographics Manager CONNECT
        • +OpenPlant Support Engineering CONNECT
        • +OpenPlant Project Administrator CONNECT
        • +OpenPlant CONNECT Edition-PlantSight Integration
        • +OpenPlant Modeler v8i
        • -OpenPlant Isometrics Manager v8i
          • +OpenPlant Isometrics Manager for OpenPlant
          • -OpenPlant Isometrics Manager for AutoPLANT
            • Installation/Upgradation Steps of OpenPlant Isometrics Manager for AutoPLANT
            • -Errors, Logs, Messages, Crashes - OpenPlant Isometrics Manager for AutoPLANT
              • Description for Bolts, Gaskets In Isometric BOM Showing as "NODESC"
              • Element ‘VALVE_HAS_VALVE_OPERATING _DEVICE’ is missing required attribute ‘sourceClass’
              • Error: Mapping of component not found, Class Name: BASE_AT_LUG_W_BOLT
              • Error: Mapping of component not found, Class Name: AT_PVIC_AT_SOCKETWELD
              • Error: The Process cannot Access the File in OpenPlant Isometrics Manager
              • Error: Scaler, Symbols or Item code are missing for TAP_CONNECTION when Branch Connected Through Stub-In Tapport
              • Error: XCHG0000: Failed to initialize OpenPlant Isometric data converter 1
              • Error: XCHG0000: Invalid Translation Format: OPIM in OpenPlant Isometrics Manager
              • Error[0]: Unable to locate ADDON (ID=XXX) to DCP
              • Error[0]: Unable to Locate ADDON (4) to DCP when Miscellaneous Attachment on Pipe
              • Error[5]Cell not found in libraries: GATSW_FT
              • Error[5] Unable to Place Symbol: FLNWNF, PGKT, GATFL When Use Custom Seed File (Backing Sheet)
              • ERROR[5]: DWG creation failed while Generating Isometric Output as DWG Format
              • To Avoid Crash for End Types WFL & Butt Weld Connections in Isometrics
              • Isometric successfully, but PCF generation failed Message in OpenPlant Isometrics Manager
              • Unresolved References Files Error on Opening DWG Isometric in AutoCAD
              • Check Internet Connection and Restart the Setup or Provide Proxy Settings
              • References-Unresolved Reference file error while opening DWG format Isometric drawing in AutoCAD
              • The Specified module could not be found (Exception from HRESULT: 0X8007007E)
            • +Open/Save - OpenPlant Isometrics Manager for AutoPLANT
            • +Processing - OpenPlant Isometrics Manager for AutoPLANT
            • +Settings/Attributes - OpenPlant Isometrics Manager for AutoPLANT
            • How to Create Special Stamps using Detail Sketches in OpenPlant Isometrics Manager in CONNECT Edition
            • How to Delete Ecxml Files, after certain Period in CONNECT Edition
            • How to Publish Isometrics in DGN, DWG and PDF Output Formats in CONNECT Edition
            • How to Save Isometrics Output on Network Drive for AutoPLANT in CONNECT Edition
          • +Release Notes - OpenPlant Isometrics Manager
          • OpenPlant Isometrics Manager [FAQ]
        • +OpenPlant Project Administrator v8i
        • +OpenPlant PID v8i
        • +OpenPlant Orthographics Manager v8i
        • +OpenPlant Support Engineering v8i
        • +OpenPlant ModelServer v8i
        • +OpenPlant Reporting v8i
        • How to Connect with Bentley Technical Support Team using Microsoft Teams
        • How to Connect with Bentley Technical Support Team using Microsoft Teams via Browser
        • How to get list of installed applications/programs on Windows Machine using Command Prompt.
        • How to get list of Windows Updates installed on the machine using Command Prompt.
        • How to Package WorkSpace to be Shareable to Users for OpenPlant Projects
      • +Bentley AutoPLANT
      • +Bentley Navigator
      • +Bentley PlantSpace
      • +Plant Project Tools
      • +Bentley Raceway and Cable Management
      • i-model Composition Service for S3D
      • Working from home with OpenPlant
      • Working from home with Bentley Raceway and Cable Management
      • Working from home with AutoPLANT Modeler
      • Your Feedback is important to us!

     
     Questions about this article, topic, or product? Click here. 

    Error: XCHG0000: Failed to initialize OpenPlant Isometric data converter 1

    Applies To
    Product(s): OpenPlant Isometrics Manager
    Version(s): 08.11.11.224 (SS6)
    Environment: Windows 7/8.1/10 (64 bit)
    Area: Errors, Logs, Messages, Crashes
    Subarea:
    Original Author: Abhijit Bute, Bentley Product Advantage Group

    Overview

    When generate isometric through Auto plant Modeler some times user face following error in AutoCAD command line.

    "Error: XCHG0000: Failed to initialize OpenPlant Isometric data converter 1"

    Problem Description

    User face "Error: XCHG0000: Failed to initialize OpenPlant Isometric data converter 1"  error while generating isometrics, common reason is because :

    Case 1: Schema edited incorrectly.

    Case 2: The schema location is incorrectly defined in the AP2ECConverter.ini file.

    Below steps will help user to overcome this problem.

    Steps to Resolve

    Case 1:

    The above errors mentioned due to wrong entries in schema, by changing project schema with out of box schema this error can be resolved.

    1. Navigate to project path.
      For Ex: C:\ProgramData\Bentley\Plant V8i\Bentley Plant V8i Projects\SAMPLE_METRIC\Config\OpenPlant

    2. Rename the project schemas folder.

    3. Copy out of box schema folder of same unit, paste it on project location.
      For Ex: C:\ProgramData\Bentley\Plant V8i\Bentley Plant V8i Configurations\Sample Metric\Config\OpenPlant

    4. Open AutoPLANT Modeler generate isometric.

    Case 2:

    1. Navigate to project path and find the file AP2ECConverter.ini file.

      For Ex: C:\ProgramData\Bentley\Plant V8i\Bentley Plant V8i Projects\SAMPLE_METRIC\Config\OpenPlant


    2. Check the schema location in the AP2ECConverter.ini file and verify if the location of the schema is at the same location as mentioned in the file.

      For Ex: \%project root%\Config\OpenPlant\schemas


    3. If the location is incorrect, change the location directory of the project with the correct location.


    4. Open AutoPLANT Modeler, generate isometric.

    Still a Problem?

    If above problem still persist, then please create a Service Request and contact Bentley Product Advantage group along with the list of all relevant details to get in depth analysis and for possible solution or workarounds. 

    See Also

    Errors, Logs, Messages, Crashes - OpenPlant Isometrics Manager for AutoPLANT
    Processing - OpenPlant Isometrics Manager To Discuss content related to Errors, Logs, Messages, Crashes in OpenPlant Isometrics Manager for AutoPLANT. Isometrics generation Errors/ Reading Logs/Message…
    Last edited over 3 years ago in OpenPlant | AutoPLANT > OpenPlant | AutoPLANT Wiki

    Comments or Corrections?

    Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!

    • 08.11.11.224
    • OPIM
    • error
    • AP-OPIM
    • 08.11.11.103
    • 08.11.11.285
    • Schemas
    • OpenPlant Isometrics Manager
    • Errors/Logs/Message dialogs/Crashes
    • XCHG0000
    • Share
    • History
    • More
    • Cancel
    • Abhijit Bute Created by Abhijit Bute
    • When: Tue, Jan 24 2017 9:45 AM
    • Swapnil Joshi Last revision by Bentley Colleague Swapnil Joshi
    • When: Wed, Dec 19 2018 5:34 AM
    • Revisions: 14
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies