Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
  • Welcome
  • Products
  • Support
  • About
  • More
  • Cancel
AutoPLANT | OpenPlant | PlantWise
  • Product Communities
  • More
AutoPLANT | OpenPlant | PlantWise
AutoPLANT | OpenPlant | PlantWise Wiki OPPID - Guidelines to ensure OPPID to APPID database field integrity
    • Sign in
    • -AutoPLANT | Bentley Raceway and Cable Management | OpenPlant | PlantWise Wiki
      • -OpenPlant
        • +CONNECT Services - OpenPlant
        • +Example Configuration - CONNECT Edition
        • +Installations - OpenPlant CONNECT Edition Applications
        • +OpenPlant Download Links & Videos
        • OpenPlant Product Compatibility
        • +OpenPlant Modeler CONNECT
        • +OpenPlant PID CONNECT
        • +OpenPlant Isometrics Manager CONNECT
        • +OpenPlant Orthographics Manager CONNECT
        • +OpenPlant Support Engineering CONNECT
        • +OpenPlant Project Administrator CONNECT
        • +OpenPlant CONNECT Edition-PlantSight Integration
        • +OpenPlant Modeler v8i
        • +OpenPlant Isometrics Manager v8i
        • +OpenPlant Project Administrator v8i
        • -OpenPlant PID v8i
          • +Application Solutions - OPPID
          • +Class Editor - OpenPlant PID
          • +Customization - OpenPlant PID
          • -Database - Plant Project
            • How to Create a new SQL Server Project and Synchronize OpenPlant PID Projects to it?
            • How do I turn on Number Auto Incrementation of Components on placement?
            • How to Associate an OpenPlant PID Drawing with Another Project
            • How to Change OPPID and Plant Project's Names
            • How to Configure Particular Project to Work in Offline Mode By Default
            • How to Create Custom Border and Map Custom Property with Database
            • How to Get Related Valve Tag in Instrument List in Data Manager
            • How to Map Custom Properties with Database
            • How to Map Input/Output Signal of Instrument in OpenPlant PID
            • How to Select Field Value from External Database PickList
            • How to Setup a Batch Routine to Sync all Drawings in my Project to the Database at one time
            • How To Show Modified Tag Format in Data Manager
            • How to Sync the Valve End Condition with Project DB
            • Importing Data into the Plant Project Database from an Excel Spreadsheet
            • Mapping Plant Project Extended Data Fields to OpenPlant PowerPID
            • OPPID - All drawings have same GUID. Drawings update database incorrectly
            • OPPID - Database Mapping Tips
            • OPPID - Document and their component Links
            • OPPID - Guidelines to ensure OPPID to APPID database field integrity
            • OPPID - How to determine Database Connection and Sync issues
            • OPPID - How To Get Motor Related to Equipment Sync to Database
            • OPPID - How to use the Class Editor Mapping Extension for the Plant Project Database
            • OPPID - Import of Associated Items
            • OPPID - YStrainer Database populate
            • OPPID Pipeline To-From SQL
            • OPPID- How to add custom properties to specific piece of equipment or sub class and link to a database
            • OPPID- SQL Logging
            • Plant Project Database - Class Mapping
            • Plant Project Database - Mappings
            • Plant Project Database - OpenPlant Validation and Repairing a Database Mapping
            • Plant Project Database - Operations with Schema Mapping and Mapping Add-in panel
            • +Plant Project Database - Oracle Install notes
            • Plant Project Database - Property Mapping
            • Plant Project Database - Relationship Mapping
            • Plant Project Database - Schema Mapping Custom Attributes
            • Plant Project Database Tag Format - Tag Codes
            • Setting OpenPlant PowerPID Project with Plant Database Project
            • SQL Server 2008 and Database to Schema Connection
            • To Import Modified Tags from Excel in Data Manager
            • Error: "Connection Test Failed" While Mapping SQL Database to Plant Project
            • Calculated EC Property Shows Failure Value in Data Manager
            • "{SERVICE_IS_RELATED_TO_EQUIPMENT(VG.0000003279)} belongs to the ECSchema {ECSchema: PlantProjectSchema.01.04} which is not supported in this connection" Error on Synchronizing from Database to Drawing
            • "Project ID 'XXXX' not found in AT_PROJ.DB3"
            • How to Move a Project Database from One Directory to Another For OPPID
            • Troubleshooting Synchronization issues using Component Selection Tool
          • +Properties - OpenPlant PID
          • +Release Notes - OpenPlant PID
          • +Training - OpenPlant PID
          • +White Papers/Guidelines - OPPID
        • +OpenPlant Orthographics Manager v8i
        • +OpenPlant Support Engineering v8i
        • +OpenPlant ModelServer v8i
        • +OpenPlant Reporting v8i
        • How to Connect with Bentley Technical Support Team using Microsoft Teams
        • How to Connect with Bentley Technical Support Team using Microsoft Teams via Browser
      • +Bentley AutoPLANT
      • +Bentley Navigator
      • +Bentley PlantSpace
      • +Plant Project Tools
      • +Bentley Raceway and Cable Management
      • i-model Composition Service for S3D
      • Working from home with OpenPlant
      • Working from home with Bentley Raceway and Cable Management
      • Working from home with AutoPLANT Modeler
    • How to Associate the Specification Based on Service in OpenPlant Modeler Connect

     
     Questions about this article, topic, or product? Click here. 

    OPPID - Guidelines to ensure OPPID to APPID database field integrity

    1. Area name must be upper case and maximum 4 character long by default. Various AutoPlant applications like I&W, Data Manager etc automatically convert area component to upper case when the tag is edited. This would cause issues if a tag synchronized from OPPID is edited in these applications.
    2. OPPID supports the default tag code only. The parser expressions defined on various classes ensure that tag numbers in the corresponding table conform to the rule defined on calculated expression. Invalid entries cause errors during synchronization/component placement etc. If there is any change in component tag code in autoplant database, the corresponding parser expression in OPPID should also be updated.
    3. A calculated property mapped with a database field must have a parser expression defined on IsDefaultValue = True for synchronization to work properly. Please note that data in the table in given field is a text value and must be parsed during synchronization.
    • TechNote
    • Database
    • Share
    • History
    • More
    • Cancel
    • Gerd.Eichler Created by Bentley Colleague Gerd.Eichler
    • When: Mon, Feb 22 2010 10:26 AM
    • Kestutis Mitkus Last revision by Bentley Colleague Kestutis Mitkus
    • When: Wed, Mar 6 2019 3:27 PM
    • Revisions: 4
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2021 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies