To show all bolt records, present in spec database of particular constraint.
In OpenPlant Modeler, user wants to select bolt records from spec database. Currently in OpenPlant Modeler calculated bolt records show as joint insertion item. Here requirement is to show all the bolt records present in spec database to manually select bolt records. This article explains, to show all bolt records of specific sizes present in spec database for LUG_JOINT.
As shown in below example, user is placing weld neck flange with butterfly valve of following standard constraints.
Weld Neck Flange - Main Size =150mm, Rating=150LB, End Cond 1 = FL, End Cond 2 = BW & Facing = FF (Flat Face)
Butterfly Valve- Main Size =150mm, Rating =150LB, End Cond 1 & 2 = LUG & Facing = FF (Flat Face)
During placement of arrangement, joint insertion items are appended for gasket & bolt. Notice number of machine bolt records as shown below.
Currently bolt records are showing as per calculation, hence showing two records. However, in spec database machine bolt have total four records as shown below.
communities.bentley.com/.../14484.how-are-bolt-lengths-calculated-in-openplant-modeler
If above problem still persist, then please create a Service Request and contact the Bentley Product Advantage group. Please include a list of all relevant details to get in depth analysis for a solution or workaround.
Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!