You are currently reviewing an older revision of this page.
08.11.09.XXX (SS5) | 08.11.11.XX (SS6)
To show continuing components in OpenPlant Isometrics Manager.
In OpenPlant Isometrics Manager, user requirement is to show continuing component to certain count. For example, user wants to show continuing component up to gate valve, weld neck flange B, Pipe B & Blind Flange in below arrangement as shown below.
But problem arises when user wants to show continuity for next repeating components, say for Pipe B. In generated isometric user is getting continuity for pipe A only as shown below.
Below wiki article explains, how to generate isometric with desired continuing components. Explanation has been accounted for modeling arrangement as shown in first image.
http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/32766.to-remove-partid-prefix-from-spectacle-blind
If above problem still persist, then please create a Service Request and contact the Bentley Product Advantage group. Please include a list of all relevant details to get in depth analysis for a solution or workaround.
Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!