You are currently reviewing an older revision of this page.
To keep the piece marks well placed inside the note box in the OpenPlant Isometrics Manager.
Sometimes when we create isometrics using AutoPLANT-OpenPlant Isometrics Manager, the piece marks overflow from the note box inside AP-OPIM.
Current Output:
Desired Output:
1. Open the isometric configuration dialog from Bentley Project Administrator.
2. In the isometric configuration dialog, open the seed file.
3. In the element menu of the seed file, select the Cells option.
4. In the cell library dialog. open the lisocomp.cel library of the corresponding project style and select the NOTE cell. Right click and open it for editing.
5. Double click on the text in the cell and change the font to MONOTEXT8.
6. Save the settings (Ctrl + F) and save the changes to the file. Regenerate the isometrics and review the result. The text style should have changed as per the dwg(autodesk) format and should be well paced within the box.
if the above problem still persists, then create a Service Request and contact the Bentley Product Advantage group. Please include a list of all relevant details to get depth analysis for a solution or workaround.
http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/12638.modifying-text-and-annotation-settings
Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections? section. THANK YOU!