Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
OpenPlant | AutoPLANT
  • Product Communities
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki OPPID - How to change the default line jumper
    • Sign In
    • -OpenPlant | AutoPLANT Wiki
      • -OpenPlant
        • +CONNECT Services - OpenPlant
        • +Example Configuration - CONNECT Edition
        • +Installations - OpenPlant CONNECT Edition Applications
        • +OpenPlant Download Links & Videos
        • OpenPlant Product Compatibility
        • +OpenPlant Modeler CONNECT
        • +OpenPlant PID CONNECT
        • +OpenPlant Isometrics Manager CONNECT
        • +OpenPlant Orthographics Manager CONNECT
        • +OpenPlant Support Engineering CONNECT
        • +OpenPlant Project Administrator CONNECT
        • +OpenPlant CONNECT Edition-PlantSight Integration
        • +OpenPlant Modeler v8i
        • +OpenPlant Isometrics Manager v8i
        • +OpenPlant Project Administrator v8i
        • -OpenPlant PID v8i
          • -Application Solutions - OPPID
            • +Brief Notes - OPPID
            • +Conversion - OPPID
            • +ECProperties - OPPID
            • +Issues and Workarounds - OPPID
            • +Logging/Debug - OPPID
            • +ProjectWise - OPPID
            • +Reports - OPPID
            • -Setup - OPPID
              • +OPPID - Annotation
              • +OPPID - Component Edit/Display Lists/Keyin
              • +OPPID - Document setup
              • +OPPID - Equipment/Nozzles
              • +OPPID - Flow Arow
              • +OPPID - Instruments
              • -OPPID - Pipeline/Pipe Run
                • OPPID - Controlling Piperun Drag Manipulation
                • OPPID - How to Change Pipe Run Display Template via a Property
                • OPPID - How to change the default line jumper
              • OPPID - Titleblocks
              • +Piping Specs - OPPID
            • +Tag Format - OPPID
            • +Upgrade Information OPPID
          • +Class Editor - OpenPlant PID
          • +Customization - OpenPlant PID
          • +Database - Plant Project
          • How to Cascade Associated Item's Value from Associated Class to Fitting Class in OpenPlant PID V8i
          • How to cascade Associated Items value from Pipeline to Reducer using Notifier in OpenPlant PID V8i
          • How to Change the Existing Cell Component Graphics in OpenPlant PID V8i
          • How to Fix Modified Tag Value Upon Second Sync in OpenPlant PID V8i
          • How to Hide the Actuator Prompt for Control Valve in OpenPlant PID V8i
          • How to include custom schema in OpenPlant PID under component manager
          • How to Point Custom WorkSpace Location in OpenPlant PID SS10
          • How to set the Fail Mode List for control valve Placement in OpenPlant PID V8i
          • +Properties - OpenPlant PID
          • +Release Notes - OpenPlant PID
          • +Training - OpenPlant PID
          • +White Papers/Guidelines - OPPID
        • +OpenPlant Orthographics Manager v8i
        • +OpenPlant Support Engineering v8i
        • +OpenPlant ModelServer v8i
        • +OpenPlant Reporting v8i
        • How to Connect with Bentley Technical Support Team using Microsoft Teams
        • How to Connect with Bentley Technical Support Team using Microsoft Teams via Browser
        • How to get list of installed applications/programs on Windows Machine using Command Prompt.
        • How to get list of Windows Updates installed on the machine using Command Prompt.
        • How to Package WorkSpace to be Shareable to Users for OpenPlant Projects
        • How to find iModel.dgn file of another domain in PlantSight
        • To Clean Residual Files After Uninstalling OpenPlant
        • To Fix Dialog not Showing After Disconnecting Multiple Monitor Display
      • +Bentley AutoPLANT
      • +Bentley Navigator
      • +Bentley PlantSpace
      • +Plant Project Tools
      • +Bentley Raceway and Cable Management
      • i-model Composition Service for S3D
      • Working from home with OpenPlant
      • Working from home with Bentley Raceway and Cable Management
      • Working from home with AutoPLANT Modeler
      • Your Feedback is important to us!
    • Learning Content for OpenPlant

     
     Questions about this article, topic, or product? Click here. 

    OPPID - How to change the default line jumper

     

    Applies To
    Product(s): OpenPlant PowerPID
    Version(s): V8i Selectseries 3+
    Environment: N/A
    Area: N/A
    Subarea: N/A
    Original Author: Gerd Eichler, Bentley Product Advantage Group

    Introduction

    By default when two lines cross a gap is created. In this process you will modify the schema so that the jumper used when two lines cross is an arc instead  of the standard gap.

    Configuring the line jumper

    1. Launch OpenPlant PowerPID
    2. From the main menu select Utilities > ClassEditor. The ECClassEditor is launched
    3. Load the supplemental schema of your project, e.g. OpenPlant_PID_Supplemental_Imperial.01.03.ecschema.xml
    4. Expand the class tree and select the class PIPING_NETWORK_SEGMENT
    5. Click the   Custom Attributes icon and add the Jumper Mapping custom attribute. Click OK
    6. Fill in the values

      Class Name: ARC_JUMPER
      Priority: 1

    7. In SS3 click the Save button. In SS4 and above the changes are automatically saved
    8. Click the Save icon
    9. Restart OpenPlant PowerPID and place a few crossing pipelines.

    Various pipeline classes use the JUMPER_MAPPING custom attribute.

    MAJOR_PIPELINE, MINOR_PIPELINE and TRACING_PIPELINE by default is set to use standard PID_JUMPER

    1. If you can't see any changes while placing Major, Minor or Tracing Pipelines, then go ta same schema and select on each of those classes.
    2. Change PID_JUMPER to ARC_JUMPER on each class jumper Mapping custom attribute same like for PIPING_NETWORK_SEGMENT and save the changes.





    Class Name is the name of the jumper to use over this class.
    Priority is specific to pipeline/pipe runs jumping.  So

    • If 2 different pipeline classes, the class with the larger Priority number jumps the smaller Order.
    • If they have same priority, then the config var is used.
    • If same pipeline classes, then the config var is used.  Currently this is in pid.cfg

      # Run breaking hierarchy, when intersecting runs have same class
      # 1 means horizontal segment will not break# 0 means vertical segment will not break SCHEMATICS_JUMPER_SAME_CLASS_HORIZONTAL_PRIORITY = 1

    Using the example above:

    • If a Major Pipeline (1) crosses a Minor Pipeline (2), the Minor would have the Pid Jumper in it.
    • If a Minor Pipeline (2) crosses a Tracing Pipeline (7), the Tracing would have the Pid Jumper in it.

    Adjusting the gap size

    The size of the jumper gap is defined in class SPACING_PIPE_RUN

    1. Select on SPACING_PIPE_RUN class and Change Double List Items value

    Comments or Corrections?

    Bentley's Product Advantage Group requests that you please submit any comments you have on this Wiki article to the "Comments" area below. THANK YOU!

    • TechNote
    • OPPID
    • OpenPLANT PowerPID
    • Openplant
    • Share
    • History
    • More
    • Cancel
    • Gerd.Eichler Created by Bentley Colleague Gerd.Eichler
    • When: Wed, Jan 13 2010 11:14 AM
    • Kestutis Mitkus Last revision by Bentley Colleague Kestutis Mitkus
    • When: Tue, Feb 5 2019 10:02 AM
    • Revisions: 20
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies