Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
OpenPlant | AutoPLANT
  • Product Communities
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki How to Change the Cell in the OpenPlant Isometrics Manager for Base Support
    • Sign In
    • -OpenPlant | AutoPLANT Wiki
      • -OpenPlant
        • +CONNECT Services - OpenPlant
        • +Example Configuration - CONNECT Edition
        • +Installations - OpenPlant CONNECT Edition Applications
        • +OpenPlant Download Links & Videos
        • OpenPlant Product Compatibility
        • +OpenPlant Modeler CONNECT
        • +OpenPlant PID CONNECT
        • +OpenPlant Isometrics Manager CONNECT
        • +OpenPlant Orthographics Manager CONNECT
        • +OpenPlant Support Engineering CONNECT
        • +OpenPlant Project Administrator CONNECT
        • +OpenPlant CONNECT Edition-PlantSight Integration
        • +OpenPlant Modeler v8i
        • -OpenPlant Isometrics Manager v8i
          • +OpenPlant Isometrics Manager for OpenPlant
          • -OpenPlant Isometrics Manager for AutoPLANT
            • Installation/Upgradation Steps of OpenPlant Isometrics Manager for AutoPLANT
            • +Errors, Logs, Messages, Crashes - OpenPlant Isometrics Manager for AutoPLANT
            • +Open/Save - OpenPlant Isometrics Manager for AutoPLANT
            • +Processing - OpenPlant Isometrics Manager for AutoPLANT
            • -Settings/Attributes - OpenPlant Isometrics Manager for AutoPLANT
              • +Modifying Text and Annotation for AutoPLANT - OpenPlant Isometrics
              • -Modifying Symbols for AutoPLANT - OpenPlant Isometrics
                • How to Add Misc Attachments Floor Opening class in OPIM Schema
                • How to Add New Valve Topworks in OpenPlant Isometrics Manager
                • How to Change Stub length in OpenPlant Isometrics Manager
                • How to Change the Cell in the OpenPlant Isometrics Manager for Base Support
                • How to Control Socket Weld Symbols in AutoPLANT - OpenPlant Isometrics
                • How to Control Threaded Weld Symbols in OpenPlant Isometrics Manager
                • How to Extend the Distance Between Valves in 4 Way Level Gauges Symbol
                • How to Fix Change Over Valve Symbols in OpenPlant Isometrics Manager
                • How to Show All Supports with Same Isometric Symbol in AutoPLANT - OpenPant Isometrics
                • How to Modify Existing Symbols in OpenPlant Isometrics Manager
                • How to Represent the Flex Hose in OpenPlant Isometrics Manager
                • How to Use Branch3D Symbol for Custom TEE in OpenPlant Isometrics Manager
                • How to Differentiate Spectacle Blank Open and Spectacle Blank Close Symbol
                • How to exclude part ID labels for GASKETS, SUPPORT, BOLT in isometric drawing in OpenPlant Isometrics Manager
                • How to Remove Additional Operator and User Label from Relief Valve
                • How to use Isometric Custom Symbol for Dummy Leg /Trunnion Support & How to include them under Supports Section of Bill of Material
              • +Modifying Dimensions for AutoPLANT - OpenPlant Isometrics
              • +Modifying DB Query: Usage, Logging, Debugging
              • +Modifying BOM for AutoPLANT - OpenPlant Isometrics
              • +Modifying Isometric Content for AutoPLANT - OpenPlant Isometrics
              • How to Append Tag Name of Instrument in Long Description
              • How to Change the Cursor Crosshair Color in OpenPlant Isometrics Manager
              • How to Enable OpenPlant Isometrics Manager to Read AutoPLANT Spool Number
              • How to Get AutoPLANT Weld IDs in OpenPlant Isometrics Manager
              • How to Get Model Name(filename) from AutoPLANT In Isometrics Using OPIM
              • How to Report the Reinforcing Pad Using Schema Customization in OpenPlant Isometrics Manager
              • How to Show Reserved Weld IDs in AutoPLANT - OpenPlant Isometrics
              • How to Show Spool Identifier and Test Port Instrument Bubble Tag Number In Isometric
              • How to Show User Label only for Reducing Branch Size
              • How to Skip THREAD or SOCKET Weld IDs in OpenPlant Isometric Manager
              • How to Suppress ‘UBR_STUB_IN’ in OpenPlant Isometrics Manager Bill of Material
              • How to Import Isometric Cells from One Project Cell Library to Another Project Cell Library
              • How to Make OpenPlant Isometrics Manager Styles Stored Globally for All Projects Using AutoPLANT Modeler
              • How to Label Pipe Support Tag
              • How to Use Grid Lines in OpenPlant Isometrics Manager for AutoPLANT
              • How to Use Isometric Cleanup When the Output Format is DWG for AutoPLANT
              • How to Add Material Property in PCF file
              • How to enable the specific Component Tags to be shown in Isometrics Using User Label
              • OpenPlant Isometrics for AutoPLANT settings for Project Isometrics
            • How to Change Miscellaneous Attachment Annotation Container in CONNECT Edition
            • How to Change Text Font, Size, Color and Location in BOM Using Text Nodes in CONNECT Edition
            • How to Create Special Stamps using Detail Sketches in OpenPlant Isometrics Manager in CONNECT Edition
            • How to Create Special Stamps using Reports in OpenPlant Isometrics Manager in CONNECT Edition
            • How to Delete Ecxml Files, after certain Period in CONNECT Edition
            • How to Export Bill of Material In CSV Excel Format for AutoPLANT Modeler in CONNECT Edition
            • How to Publish Isometrics in DGN, DWG and PDF Output Formats in CONNECT Edition
            • How to Represent Flexible Hose in OpenPlant Isometrics Manager CONNECT Edition
            • How to Save Isometrics Output on Network Drive for AutoPLANT in CONNECT Edition
          • +Release Notes - OpenPlant Isometrics Manager
          • OpenPlant Isometrics Manager [FAQ]
        • +OpenPlant Project Administrator v8i
        • +OpenPlant PID v8i
        • +OpenPlant Orthographics Manager v8i
        • +OpenPlant Support Engineering v8i
        • +OpenPlant ModelServer v8i
        • +OpenPlant Reporting v8i
        • How to Connect with Bentley Technical Support Team using Microsoft Teams
        • How to Connect with Bentley Technical Support Team using Microsoft Teams via Browser
        • How to get list of installed applications/programs on Windows Machine using Command Prompt.
        • How to get list of Windows Updates installed on the machine using Command Prompt.
        • How to Package WorkSpace to be Shareable to Users for OpenPlant Projects
        • How to find iModel.dgn file of another domain in PlantSight
        • To Clean Residual Files After Uninstalling OpenPlant
        • To Fix Dialog not Showing After Disconnecting Multiple Monitor Display
        • To Fix Error "A required privilege is not held by the client" When Generating External Reports
      • +Bentley AutoPLANT
      • +Bentley Navigator
      • +Bentley PlantSpace
      • +Plant Project Tools
      • +Bentley Raceway and Cable Management
      • i-model Composition Service for S3D
      • Working from home with OpenPlant
      • Working from home with Bentley Raceway and Cable Management
      • Working from home with AutoPLANT Modeler
      • Your Feedback is important to us!
    • Learning Content for OpenPlant

     
     Questions about this article, topic, or product? Click here. 

    How to Change the Cell in the OpenPlant Isometrics Manager for Base Support

    Applies To
    Product(s): OpenPlant Isometrics Manager
    Version(s): 08.11.11.224 (SS6)
    Environment: Windows 7/8.1/10 (64 bit)
    Area: Settings/Attributes
    Subarea: Modifying Symbols
    Original Author: Swapnil Joshi, Bentley Product Advantage Group

    To change the cell in the OpenPlant Isometrics Manager for Base Support.

    Background

    The user wants to change the existing SUPP symbol to SUPP_ADJBASE for Base support in the OpenPlant Isometrics Manager but the Isometric Component is greyed out hence the user cannot change the symbol.

    Steps to Accomplish

    1. Open Bentley Class Editor v8i.


    2. Click on Open schemas, navigate to the Project Root and open OpenPlant_3D schema.


    3. Right click on the schema and select the Supplement schema.


    4. Supplement it with Isometrics IsoExtractor schema.


    5. Click on find Class Option.


    6. Search for Support.


    7. Navigate to the Base Support Class.


    8. The Isometric Component is greyed out.


    9. Select Support Class.


    10. Right click on the support class, select Custom Attributes and Copy.


    11. Copy the Custom Attribute Isometric Component.


    12. Select the Base support class, right click on it and select Custom Attributes and Paste.


    13. Isometric Component will now be editable.


    14. Change the cell name with required cell name.


    15. Test by placing in a model.

    See Also

    Comments or Corrections?

    Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!

    • Isometric Configuration
    • AutoPLANT Modeler
    • Class Editor
    • Schemas
    • OpenPlant Isometrics Manager
    • support
    • Share
    • History
    • More
    • Cancel
    • Swapnil Joshi Created by Bentley Colleague Swapnil Joshi
    • When: Wed, Aug 23 2017 5:39 AM
    • Swapnil Joshi Last revision by Bentley Colleague Swapnil Joshi
    • When: Wed, Dec 19 2018 5:24 AM
    • Revisions: 4
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies