When user is working on Water/Waste industry they only require to have Size and Service of Pipe to show in OpenPlant Orthographic Manager. Below are the steps to achieve that requirement.
Launch Bentley Class Editor.
Open OpenPlant_3D schema.
C:\ProgramData\Bentley\OrthographicsManager V8i\WorkSpace\Projects\Sample_Imperial\Dataset\Schemas
Navigate to PIPE Class.
Switch to LINENUMBER Property.
PIPE --> Custom Attribute --> Add/Remove.
Save all Changes.
Generate Drawing in OpenPlant Orthographic Manager.