You are currently reviewing an older revision of this page.
Applies To
Product(s):
OpenPlant PID
Version(s):
08.11.10.XXX & Higher
Environment:
Windows 7/8 (64 bit)
Area:
Database
Subarea:
Original Author:
Nikhil Salunkhe, Bentley Product Advantage Group
In OpenPlant PID, user wanted to choose Manufacturer property from pick-list which is created in database. After creating database, pick-list is displaying in OpenPlant PID but unable to select any of the Manufacturer property. In below Wiki article, we are defining the steps on how to select ‘Manufacturer’ from pick list.
Fill below data in Database, then right click on Manufacturer and click on Design view. See below image
Define Data type for every field name after changing to Design view.
Save database with 2002-03 Compatible version then Close Manufacturer.mdb file.
Launch Class editor.
Open OpenPlant_PID.01.07.ecschema.xml schema.
Supplement with OpenPlant_PID_Supplemental_Imperial.01.07.ecschema.xml schema
Expand Classes tab and navigate to Vessel class in Plant Base Object, select Properties tab, go to Manufacturer Property and click ‘Override’ then select Manufacturer property, right click and add External Data source Definition Mapping and Extend Type Custom attributes.
Right click on Vessel, go to Element information and select manufacturer Property in General info Section and Select ‘TANKS ARE US’ option. See below image.
Notice the change in Manufacturer property ‘TANKS ARE US’, See below image.
Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!