I need to create a conduit catalog that includes fittings with very large values for Bend Radius, but I get a message saying I can't have a value that high:
DNA Variables SettingThe value can't be more than 200
Before creating the catalog, modify the max value for BendRadius in the DNA_...bend.xml file for the catalog to be used as a template. For example, the max value has been set to 5000.0 in the excerpt below.
<V007 type="UI" min="1.0" max="5000.0">> <Name>BendRadius</Name> <VariableType>real</VariableType> <DefaultValue>200</DefaultValue> <Unit>default</Unit> <Prompt>Bend radius</Prompt> </V007>
Refer to the CAT_MySourceCatalog.xml file to determine the DNA_...bend.xml file to modify.
Create the new catalog without the desired bend radius.
Modify the max value for BendRadius in the DNA_...bend.xml file for the new catalog. For example, the max value has been set to 5000.0 in the excerpt below.
Use the Raceway Catalog Creation tool to Edit the new catalog and add the desired bend radius.