Background
When running an Iso, the text (support tag) is fitting in the frame in DGN output, but not in DWG output.
(DGN OUTPUT)
(DWG OUTPUT) Steps to resolve:
Browse to: #\YOUR_PROJECT\Config\OpenPlant\Isometrics\styles\IFC\cell and double click on the lisocomp.cel to open it.Click on the button “Models” and scroll to the NOTE label and select it.
In the active NOTE model:1. Select the text.2. With the pulldown button scroll to the text type “ISOCP and select it.3. Click in the label section to make the changing active.
Close the file.Run the iso again.
Still a Problem?
If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group. Please include a list of all relevant details to get in depth analysis for a solution or workaround.
Comments or Corrections?
Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!