Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
  • Welcome
  • Products
  • Support
  • About
  • More
  • Cancel
AutoPLANT | OpenPlant | PlantWise
  • Product Communities
  • More
AutoPLANT | OpenPlant | PlantWise
AutoPLANT | OpenPlant | PlantWise Wiki How To Fix "Unable to Load Schema For StressApp" Error in OpenPlant Modeler
    • Sign in
    • -AutoPLANT | Bentley Raceway and Cable Management | OpenPlant | PlantWise Wiki
      • -OpenPlant
        • +CONNECT Services - OpenPlant
        • +Example Configuration - CONNECT Edition
        • +Installations - OpenPlant CONNECT Edition Applications
        • +OpenPlant Download Links & Videos
        • OpenPlant Product Compatibility
        • +OpenPlant Modeler CONNECT
        • +OpenPlant PID CONNECT
        • +OpenPlant Isometrics Manager CONNECT
        • +OpenPlant Orthographics Manager CONNECT
        • +OpenPlant Support Engineering CONNECT
        • +OpenPlant Project Administrator CONNECT
        • +OpenPlant CONNECT Edition-PlantSight Integration
        • -OpenPlant Modeler v8i
          • +Component - OpenPlant Modeler
          • +Drawing Generation- OpenPlant Modeler
          • -Errors, Logs, Messages, Crashes - OpenPlant Modeler
            • "Failed to Find Cell Library for Diagram" Error While Placing Equipment
            • "No Component Found With Initial Selection From Specs" Appears While Placing Component
            • Attach OpenPlant Modeler Objects in ProSteel
            • Deleting User Data Files Local and Roaming
            • Duplicate Key Tags Message in OpenPlant Modeler
            • Graphics Issue- Distorted graphics- Display Graphics in OpenPlant Modeler
            • How To Fix "Unable to Load Schema For StressApp" Error in OpenPlant Modeler
            • Invalid Catalog Selected Issues in OpenPlant Specification Generator
            • Invalid Joint Error while Validating Joint for Custom Components
            • Line 241 Error-Launching OpenPlant Modeler
            • Property is Read Only Error in OpenPlant Modeler
            • Selected Spec is Incompatible With the Current Project
            • +Spec Validation Report Error: Some Properties in Spec Do Not Match in Component
            • Standard Preferences Dialog Disappeared from OpenPlant Modeler
            • StartUp Error-Launching OpenPlant Modeler
            • Structural Synchronizer Engine Not Found Message when Selecting Repository from Structural tab
            • Tap Port Connection On Blind Flange Placement Issue
            • To Fix Incorrect Property Update while using AutoMatch Option
            • To Fix Joint Connection Error While Modeling Component
            • To Fix Missing Ports Information for PIPE_ELBOW_5_DEGREE in OpenPlant Modeler
            • To Fix Pro Steel Models Referenced in OpenPlant using Object Enabler
            • To Fix Support Rotation Issue By Manual Rotation or By placing supports using OpenPlant Support Engineering .
            • To Fix Unhandled Exception Error while Launching Pipeline Manager in OpenPlant Modeler V8i
            • To Fix Unhandled Exception Error “Index was outside the bounds of the array”
            • Too Many Results (XXXX).Select this to see items in details
            • Unable to Delete Corrupt Component in OpenPlant Modeler
            • Unable to Find Catalog Issue in OpenPlant Specification Generator
            • Wafer Joint on Components with Different Facing and Rating Shows Error While Placement
          • +Import/Export- OpenPlant Modeler
          • +Installation - OpenPlant Modeler
          • OpenPlant HVAC-OpenPlant Modeler
          • OpenPlant Modeler [FAQ]
          • +OpenPlant Specification Generator
          • +ProjectWise - OpenPlant Modeler
          • +Properties - OpenPlant Modeler
          • +Release Notes - OpenPlant Modeler
          • +Schema - OpenPlant Modeler
          • +Settings/Attributes - OpenPlant Modeler
          • +Structural Modeling Components (SMC)- OpenPlant Modeler
          • +Tasks - OpenPlant Modeler
          • +Training - OpenPlant Modeler
        • +OpenPlant Isometrics Manager v8i
        • +OpenPlant Project Administrator v8i
        • +OpenPlant PID v8i
        • +OpenPlant Orthographics Manager v8i
        • +OpenPlant Support Engineering v8i
        • +OpenPlant ModelServer v8i
        • +OpenPlant Reporting v8i
        • How to Connect with Bentley Technical Support Team using Microsoft Teams
        • How to Connect with Bentley Technical Support Team using Microsoft Teams via Browser
      • +Bentley AutoPLANT
      • +Bentley Navigator
      • +Bentley PlantSpace
      • +Plant Project Tools
      • +Bentley Raceway and Cable Management
      • i-model Composition Service for S3D
      • Working from home with OpenPlant
      • Working from home with Bentley Raceway and Cable Management
      • Working from home with AutoPLANT Modeler
    • How to Associate the Specification Based on Service in OpenPlant Modeler Connect

     
     Questions about this article, topic, or product? Click here. 

    How To Fix "Unable to Load Schema For StressApp" Error in OpenPlant Modeler


    Applies To 
    Product(s): OpenPlant Modeler
    Version(s):

    08.11.09.XXX (SS5) | 08.11.11.XX (SS6)

    Environment:  Windows 7/8.1/10 (64-bit)
    Area:  Pipeline Manager
    Subarea:  Stress Interface
    Original Author: Deepak Singh,Bentley Product Advantage Group

    In OpenPlant Modeler, how to fix error for unable to load schema for StessApp in OpenPlant Modeler

    Background

    From Pipeline Manager, upon using Export Data for Stress Analysis feature, throws error as “Unable to load Schema for StressApp”. Refer below image, such issue can be seen due to incorrect installation of OpenPlant Modeler or due to schema file missing from specific directory. This wiki will explain how to fix this error.


    Steps to Accomplish

    Case A: When OpenPlant Modeler fresh installation is available to another machine

    1. Navigate to below mentioned location & ensure that stressapp.01.01. ecschema is available.

    In case if above highlighted schema file is not present, copy stressapp.01.01. ecschema file from another machine where OpenPlant Modeler is installed & paste it to above highlighted location.

    Case B: When OpenPlant Modeler is not installed to another machine.

    Note: Before proceeding above step, ensure to have backup of your workspace.

    1. Perform fresh installation of OpenPlant Modeler, this will automatically place missing stressapp.01.01. ecschema to correct directory.

    See Also

    Still a Problem?

    If above problem still persists, then please create a Service Request and contact the Bentley Product Advantage group.  Please include a list of all relevant details to get in depth analysis for a solution or workaround. 

    See Video

    • OpenPlant Modeler
    • Unable to Load Schema for StressApp in OpenPlant Modeler
    • OPM
    • Pipeline Manager Stress Error in OPM
    • StressApp Error in OpenPlant Modeler
    • Unable to Load Schema for StressApp
    • StressApp Not working in OPM
    • Pipeline Manager Error Unable to Load Schema for StressApp
    • Share
    • History
    • More
    • Cancel
    • Deepak Singh Created by Bentley Colleague Deepak Singh
    • When: Mon, Jul 9 2018 7:15 AM
    • Deepak Singh Last revision by Bentley Colleague Deepak Singh
    • When: Mon, Jul 9 2018 7:58 AM
    • Revisions: 2
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2021 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies