<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>How to Leave Custom Length Value after using Change Spec / Change Size Option</title><link>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/40007/how-to-leave-custom-length-value-after-using-change-spec-change-size-option</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>How to Leave Custom Length Value after using Change Spec / Change Size Option</title><link>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/40007/how-to-leave-custom-length-value-after-using-change-spec-change-size-option</link><pubDate>Fri, 04 Jan 2019 11:49:05 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:59cc1f1b-365c-4f9a-88c5-f8e1c76fc0f6</guid><dc:creator>Kestutis Mitkus</dc:creator><comments>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/40007/how-to-leave-custom-length-value-after-using-change-spec-change-size-option#comments</comments><description>Current Revision posted to OpenPlant | AutoPLANT Wiki by Kestutis Mitkus on 1/4/2019 11:49:05 AM&lt;br /&gt;
&lt;p&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;height:124px;width:500px;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Applies To&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenPlant Modeler&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.11.09.XXX (SS5) | 08.11.11.XXX (SS6)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Windows 7/8.1/10 (64 bit)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Settings/Attributes&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;-&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Kestutis Mitkus,&amp;nbsp;Bentley Product Advantage Group&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h2&gt;Overview&lt;/h2&gt;
&lt;p&gt;In OpenPlant Modeler, various options are designed to use component data from Specifications, but sometimes there are cases where there is no need to use .&amp;nbsp;&lt;/p&gt;
&lt;h3&gt;Problem Description&lt;/h3&gt;
&lt;p&gt;In OpenPlant Modeler we place Inline Piping Component and then changing its Length. When we will try to change components Size using Spec/Size change option, it will Automatically change component length to the value which is written in COMP_LEN field of specification. Such behavior is not useful for user who have modeled large Piping systems and after any size change they will be forced to go and try modify each Inline Component manually.&lt;/p&gt;
&lt;h3&gt;Steps to Resolve&lt;/h3&gt;
&lt;ol&gt;
&lt;li&gt;Launch the Bentley Class Editor and open the following schemas.&lt;br /&gt;&lt;br /&gt;OpenPlant_3D.01.07.ecschema.xml &amp;nbsp;(%ProjectRoot%...\WorkSpace\ &amp;nbsp;&amp;nbsp;&amp;nbsp;Projects\OPModeler_Metric\ DataSet\Schemas\).&lt;br /&gt;&lt;br /&gt;Supplement With,OpenPlant_3D_Supplemental_Modeling.01.07. ecschema.xml (%ProjectRoot%...\WorkSpace\Projects\OPModeler_Metric\ DataSet \ Schemas\).&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;&lt;i&gt;For More information on supplementing schema&amp;nbsp;&lt;a title="To Supplement schemas" href="/products/plant/design___engineering/w/plant_design_and_engineering__wiki/31218.to-open-schema-in-class-editor"&gt;click here&amp;gt;&amp;gt;&amp;gt;&amp;gt;&lt;/a&gt;&lt;/i&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Search for Inline Pipe Component class, select on Properties section, LENGTH property&amp;nbsp;and scroll till OpenPlant_Physical_Catalogue_Property_Map custom attribute.&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_24_2D00_56.png" /&gt;&lt;br /&gt;&lt;br /&gt;Verify, that system is always checking COMP_LEN value on specification and this is the cause of such OpenPlant behavior.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Select to Add/Remove Custom Attributes. Then in opened dialog, remove existing OpenPlant_Physical_Catalogue_Property_Map&amp;nbsp; and add Default value&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_26_2D00_03.png" /&gt;&lt;br /&gt;&lt;br /&gt;Input some standard Default value which always will be used while placing new Inline Pipe Component, but wont be used anymore while using Change Spec / Size option.&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_27_2D00_19.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Save &amp;amp; Close Schema.&lt;/li&gt;
&lt;li&gt;Launch OpenPlant Modeler, place any Generic Pipe Component and modify its Length&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_44_2D00_03.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_45_2D00_36.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_51_2D00_16.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Now use Spec / Size change option to modify its Size from 100 to 125&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_46_2D00_49.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_48_2D00_22.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Save the settings and verify the result as shown below.&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_50_2D00_08.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;All procedure of how to do it can be checked in this video below&lt;/p&gt;
&lt;h3&gt;See Video&lt;/h3&gt;
&lt;p&gt;&lt;a href="https://communities.bentley.com/products/plant/m/plant_design_and_engineering_files/273403"&gt;communities.bentley.com/.../273403&lt;/a&gt;&lt;/p&gt;
&lt;h2&gt;Comments or Corrections?&lt;/h2&gt;
&lt;p&gt;Bentley&amp;#39;s Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Custom Length Value, OpenPlant Modeler, Change Size, Change Spec&lt;/div&gt;
</description></item><item><title>How to Leave Custom Length Value after using Change Spec / Change Size Option</title><link>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/40007/how-to-leave-custom-length-value-after-using-change-spec-change-size-option/revision/7</link><pubDate>Thu, 18 Oct 2018 13:41:34 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:59cc1f1b-365c-4f9a-88c5-f8e1c76fc0f6</guid><dc:creator>Kestutis Mitkus</dc:creator><comments>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/40007/how-to-leave-custom-length-value-after-using-change-spec-change-size-option#comments</comments><description>Revision 7 posted to OpenPlant | AutoPLANT Wiki by Kestutis Mitkus on 10/18/2018 1:41:34 PM&lt;br /&gt;
&lt;p&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;height:124px;width:500px;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Applies To&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenPlant Modeler&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.11.09.XXX (SS5) | 08.11.11.XXX (SS6)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Windows 7/8.1/10 (64 bit)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Settings/Attributes&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;-&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Kestutis Mitkus,&amp;nbsp;Bentley Product Advantage Group&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h2&gt;Overview&lt;/h2&gt;
&lt;p&gt;In OpenPlant Modeler, various options are designed to use component data from Specifications, but sometimes there are cases where there is no need to use .&amp;nbsp;&lt;/p&gt;
&lt;h3&gt;Problem Description&lt;/h3&gt;
&lt;p&gt;In OpenPlant Modeler we place Inline Piping Component and then changing its Length. When we will try to change components Size using Spec/Size change option, it will Automatically change component length to the value which is written in COMP_LEN field of specification. Such behavior is not useful for user who have modeled large Piping systems and after any size change they will be forced to go and try modify each Inline Component manually.&lt;/p&gt;
&lt;h3&gt;Steps to Resolve&lt;/h3&gt;
&lt;ol&gt;
&lt;li&gt;Launch the Bentley Class Editor and open the following schemas.&lt;br /&gt;&lt;br /&gt;OpenPlant_3D.01.07.ecschema.xml &amp;nbsp;(%ProjectRoot%...\WorkSpace\ &amp;nbsp;&amp;nbsp;&amp;nbsp;Projects\OPModeler_Metric\ DataSet\Schemas\).&lt;br /&gt;&lt;br /&gt;Supplement With,OpenPlant_3D_Supplemental_Modeling.01.07. ecschema.xml (%ProjectRoot%...\WorkSpace\Projects\OPModeler_Metric\ DataSet \ Schemas\).&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;&lt;i&gt;For More information on supplementing schema&amp;nbsp;&lt;a title="To Supplement schemas" href="/products/plant/design___engineering/w/plant_design_and_engineering__wiki/31218.to-open-schema-in-class-editor"&gt;click here&amp;gt;&amp;gt;&amp;gt;&amp;gt;&lt;/a&gt;&lt;/i&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Search for Inline Pipe Component class, select on Properties section, LENGTH property&amp;nbsp;and scroll till OpenPlant_Physical_Catalogue_Property_Map custom attribute.&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_24_2D00_56.png" /&gt;&lt;br /&gt;&lt;br /&gt;Verify, that system is always checking COMP_LEN value on specification and this is the cause of such OpenPlant behavior.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Select to Add/Remove Custom Attributes. Then in opened dialog, remove existing OpenPlant_Physical_Catalogue_Property_Map&amp;nbsp; and add Default value&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_26_2D00_03.png" /&gt;&lt;br /&gt;&lt;br /&gt;Input some standard Default value which always will be used while placing new Inline Pipe Component, but wont be used anymore while using Change Spec / Size option.&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_27_2D00_19.png" /&gt;&lt;/li&gt;
&lt;li&gt;Save &amp;amp; Close Schema.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Launch OpenPlant Modeler, place any Generic Pipe Component and modify its Length&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_44_2D00_03.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_45_2D00_36.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_51_2D00_16.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Now use Spec / Size change option to modify its Size from 100 to 125&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_46_2D00_49.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_48_2D00_22.png" /&gt;&lt;/li&gt;
&lt;li&gt;Save the settings and verify the result as shown below.&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_50_2D00_08.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;All procedure of how to do it can be checked in this video below&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;
&lt;h3&gt;See Video&lt;/h3&gt;
&lt;p&gt;&lt;a title="How to Leave Custom Length Value after using Change Spec Change Size Option" href="/products/plant/m/plant_design_and_engineering_files/273403"&gt;https://communities.bentley.com/products/plant/m/plant_design_and_engineering_files/273403&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h2&gt;Comments or Corrections?&lt;/h2&gt;
&lt;p&gt;Bentley&amp;#39;s Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Custom Length Value, OpenPlant Modeler, Change Size, Change Spec&lt;/div&gt;
</description></item><item><title>How to Leave Custom Length Value after using Change Spec / Change Size Option</title><link>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/40007/how-to-leave-custom-length-value-after-using-change-spec-change-size-option/revision/6</link><pubDate>Thu, 18 Oct 2018 13:37:27 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:59cc1f1b-365c-4f9a-88c5-f8e1c76fc0f6</guid><dc:creator>Kestutis Mitkus</dc:creator><comments>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/40007/how-to-leave-custom-length-value-after-using-change-spec-change-size-option#comments</comments><description>Revision 6 posted to OpenPlant | AutoPLANT Wiki by Kestutis Mitkus on 10/18/2018 1:37:27 PM&lt;br /&gt;
&lt;p&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;height:124px;width:500px;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Applies To&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenPlant Modeler&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.11.09.XXX (SS5) | 08.11.11.XXX (SS6)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Windows 7/8.1/10 (64 bit)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Settings/Attributes&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;-&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Kestutis Mitkus,&amp;nbsp;Bentley Product Advantage Group&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h2&gt;Overview&lt;/h2&gt;
&lt;p&gt;In OpenPlant Modeler, various options are designed to use component data from Specifications, but sometimes there are cases where there is no need to use .&amp;nbsp;&lt;/p&gt;
&lt;h3&gt;Problem Description&lt;/h3&gt;
&lt;p&gt;In OpenPlant Modeler we place Inline Piping Component and then changing its Length. When we will try to change components Size using Spec/Size change option, it will Automatically change component length to the value which is written in COMP_LEN field of specification. Such behavior is not useful for user who have modeled large Piping systems and after any size change they will be forced to go and try modify each Inline Component manually.&lt;/p&gt;
&lt;h3&gt;Steps to Resolve&lt;/h3&gt;
&lt;ol&gt;
&lt;li&gt;Launch the Bentley Class Editor and open the following schemas.&lt;br /&gt;&lt;br /&gt;OpenPlant_3D.01.07.ecschema.xml &amp;nbsp;(%ProjectRoot%...\WorkSpace\ &amp;nbsp;&amp;nbsp;&amp;nbsp;Projects\OPModeler_Metric\ DataSet\Schemas\).&lt;br /&gt;&lt;br /&gt;Supplement With,OpenPlant_3D_Supplemental_Modeling.01.07. ecschema.xml (%ProjectRoot%...\WorkSpace\Projects\OPModeler_Metric\ DataSet \ Schemas\).&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;&lt;i&gt;For More information on supplementing schema&amp;nbsp;&lt;a title="To Supplement schemas" href="/products/plant/design___engineering/w/plant_design_and_engineering__wiki/31218.to-open-schema-in-class-editor"&gt;click here&amp;gt;&amp;gt;&amp;gt;&amp;gt;&lt;/a&gt;&lt;/i&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Search for Inline Pipe Component class, select on Properties section, LENGTH property&amp;nbsp;and scroll till OpenPlant_Physical_Catalogue_Property_Map custom attribute.&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_24_2D00_56.png" /&gt;&lt;br /&gt;&lt;br /&gt;Verify, that system is always checking COMP_LEN value on specification and this is the cause of such OpenPlant behavior.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Select to Add/Remove Custom Attributes. Then in opened dialog, remove existing OpenPlant_Physical_Catalogue_Property_Map&amp;nbsp; and add Default value&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_26_2D00_03.png" /&gt;&lt;br /&gt;&lt;br /&gt;Input some standard Default value which always will be used while placing new Inline Pipe Component, but wont be used anymore while using Change Spec / Size option.&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_27_2D00_19.png" /&gt;&lt;/li&gt;
&lt;li&gt;Save &amp;amp; Close Schema.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Launch OpenPlant Modeler, place any Generic Pipe Component and modify its Length&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_44_2D00_03.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_45_2D00_36.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_51_2D00_16.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Now use Spec / Size change option to modify its Size from 100 to 125&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_46_2D00_49.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_48_2D00_22.png" /&gt;&lt;/li&gt;
&lt;li&gt;Save the settings and verify the result as shown below.&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_50_2D00_08.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;All procedure of how to do it can be checked in this video below&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;
&lt;h3&gt;See Video&lt;/h3&gt;
&lt;p&gt;&lt;a href="/products/plant/m/plant_design_and_engineering_files/273403"&gt;https://communities.bentley.com/products/plant/m/plant_design_and_engineering_files/273403&lt;/a&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h2&gt;Comments or Corrections?&lt;/h2&gt;
&lt;p&gt;Bentley&amp;#39;s Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Custom Length Value, OpenPlant Modeler, Change Size, Change Spec&lt;/div&gt;
</description></item><item><title>How to Leave Custom Length Value after using Change Spec / Change Size Option</title><link>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/40007/how-to-leave-custom-length-value-after-using-change-spec-change-size-option/revision/5</link><pubDate>Wed, 17 Oct 2018 13:59:45 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:59cc1f1b-365c-4f9a-88c5-f8e1c76fc0f6</guid><dc:creator>Kestutis Mitkus</dc:creator><comments>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/40007/how-to-leave-custom-length-value-after-using-change-spec-change-size-option#comments</comments><description>Revision 5 posted to OpenPlant | AutoPLANT Wiki by Kestutis Mitkus on 10/17/2018 1:59:45 PM&lt;br /&gt;
&lt;p&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;height:124px;width:500px;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Applies To&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenPlant Modeler&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.11.09.XXX (SS5) | 08.11.11.XXX (SS6)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Windows 7/8.1/10 (64 bit)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Settings/Attributes&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;-&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Kestutis Mitkus,&amp;nbsp;Bentley Product Advantage Group&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h2&gt;Overview&lt;/h2&gt;
&lt;p&gt;In OpenPlant Modeler, various options are designed to use component data from Specifications, but sometimes there are cases where there is no need to use .&amp;nbsp;&lt;/p&gt;
&lt;h3&gt;Problem Description&lt;/h3&gt;
&lt;p&gt;In OpenPlant Modeler we place Inline Piping Component and then changing its Length. When we will try to change components Size using Spec/Size change option, it will Automatically change component length to the value which is written in COMP_LEN field of specification. Such behavior is not useful for user who have modeled large Piping systems and after any size change they will be forced to go and try modify each Inline Component manually.&lt;/p&gt;
&lt;h3&gt;Steps to Resolve&lt;/h3&gt;
&lt;ol&gt;
&lt;li&gt;Launch the Bentley Class Editor and open the following schemas.&lt;br /&gt;&lt;br /&gt;OpenPlant_3D.01.07.ecschema.xml &amp;nbsp;(%ProjectRoot%...\WorkSpace\ &amp;nbsp;&amp;nbsp;&amp;nbsp;Projects\OPModeler_Metric\ DataSet\Schemas\).&lt;br /&gt;&lt;br /&gt;Supplement With,OpenPlant_3D_Supplemental_Modeling.01.07. ecschema.xml (%ProjectRoot%...\WorkSpace\Projects\OPModeler_Metric\ DataSet \ Schemas\).&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;&lt;i&gt;For More information on supplementing schema&amp;nbsp;&lt;a title="To Supplement schemas" href="/products/plant/design___engineering/w/plant_design_and_engineering__wiki/31218.to-open-schema-in-class-editor"&gt;click here&amp;gt;&amp;gt;&amp;gt;&amp;gt;&lt;/a&gt;&lt;/i&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Search for Inline Pipe Component class, select on Properties section, LENGTH property&amp;nbsp;and scroll till OpenPlant_Physical_Catalogue_Property_Map custom attribute.&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_24_2D00_56.png" /&gt;&lt;br /&gt;&lt;br /&gt;Verify, that system is always checking COMP_LEN value on specification and this is the cause of such OpenPlant behavior.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Select to Add/Remove Custom Attributes. Then in opened dialog, remove existing OpenPlant_Physical_Catalogue_Property_Map&amp;nbsp; and add Default value&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_26_2D00_03.png" /&gt;&lt;br /&gt;&lt;br /&gt;Input some standard Default value which always will be used while placing new Inline Pipe Component, but wont be used anymore while using Change Spec / Size option.&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_27_2D00_19.png" /&gt;&lt;/li&gt;
&lt;li&gt;Save &amp;amp; Close Schema.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Launch OpenPlant Modeler, place any Generic Pipe Component and modify its Length&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_44_2D00_03.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_45_2D00_36.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_51_2D00_16.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Now use Spec / Size change option to modify its Size from 100 to 125&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_46_2D00_49.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_48_2D00_22.png" /&gt;&lt;/li&gt;
&lt;li&gt;Save the settings and verify the result as shown below.&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_50_2D00_08.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;All procedure of how to do it can be checked in this video:&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;
&lt;h3&gt;See Also&lt;/h3&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h2&gt;Comments or Corrections?&lt;/h2&gt;
&lt;p&gt;Bentley&amp;#39;s Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Custom Length Value, OpenPlant Modeler, Change Size, Change Spec&lt;/div&gt;
</description></item><item><title>How to Leave Custom Length Value after using Change Spec / Change Size Option</title><link>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/40007/how-to-leave-custom-length-value-after-using-change-spec-change-size-option/revision/4</link><pubDate>Wed, 17 Oct 2018 10:06:48 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:59cc1f1b-365c-4f9a-88c5-f8e1c76fc0f6</guid><dc:creator>Kestutis Mitkus</dc:creator><comments>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/40007/how-to-leave-custom-length-value-after-using-change-spec-change-size-option#comments</comments><description>Revision 4 posted to OpenPlant | AutoPLANT Wiki by Kestutis Mitkus on 10/17/2018 10:06:48 AM&lt;br /&gt;
&lt;p&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;height:124px;width:500px;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Applies To&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenPlant Modeler&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.11.09.XXX (SS5) | 08.11.11.XXX (SS6)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Windows 7/8.1/10 (64 bit)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Settings/Attributes&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;-&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Kestutis Mitkus,&amp;nbsp;Bentley Product Advantage Group&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h2&gt;Overview&lt;/h2&gt;
&lt;p&gt;In OpenPlant Modeler, various options are designed to use component data from Specifications, but sometimes there are cases where there is no need to use .&amp;nbsp;&lt;/p&gt;
&lt;h3&gt;Problem Description&lt;/h3&gt;
&lt;p&gt;In OpenPlant Modeler we place Inline Piping Component and then changing its Length. When we will try to change components Size using Spec/Size change option, it will Automatically change component length to the value which is written in COMP_LEN field of specification. Such behavior is not useful for user who have modeled large Piping systems and after any size change they will be forced to go and try modify each Inline Component manually.&lt;/p&gt;
&lt;h3&gt;Steps to Resolve&lt;/h3&gt;
&lt;ol&gt;
&lt;li&gt;Launch the Bentley Class Editor and open the following schemas.&lt;br /&gt;&lt;br /&gt;OpenPlant_3D.01.07.ecschema.xml &amp;nbsp;(%ProjectRoot%...\WorkSpace\ &amp;nbsp;&amp;nbsp;&amp;nbsp;Projects\OPModeler_Metric\ DataSet\Schemas\).&lt;br /&gt;&lt;br /&gt;Supplement With,OpenPlant_3D_Supplemental_Modeling.01.07. ecschema.xml (%ProjectRoot%...\WorkSpace\Projects\OPModeler_Metric\ DataSet \ Schemas\).&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;&lt;i&gt;For More information on supplementing schema&amp;nbsp;&lt;a title="To Supplement schemas" href="/products/plant/design___engineering/w/plant_design_and_engineering__wiki/31218.to-open-schema-in-class-editor"&gt;click here&amp;gt;&amp;gt;&amp;gt;&amp;gt;&lt;/a&gt;&lt;/i&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Search for Inline Pipe Component class, select on Properties section, LENGTH property&amp;nbsp;and scroll till OpenPlant_Physical_Catalogue_Property_Map custom attribute.&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_24_2D00_56.png" /&gt;&lt;br /&gt;&lt;br /&gt;Verify, that system is always checking COMP_LEN value on specification and this is the cause of such OpenPlant behavior.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Select to Add/Remove Custom Attributes. Then in opened dialog, remove existing OpenPlant_Physical_Catalogue_Property_Map&amp;nbsp; and add Default value&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_26_2D00_03.png" /&gt;&lt;br /&gt;&lt;br /&gt;Input some standard Default value which always will be used while placing new Inline Pipe Component, but wont be used anymore while using Change Spec / Size option.&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_27_2D00_19.png" /&gt;&lt;/li&gt;
&lt;li&gt;Save &amp;amp; Close Schema.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Launch OpenPlant Modeler and place any Generic Pipe Component&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_44_2D00_03.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_45_2D00_36.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Modify its Length&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_51_2D00_16.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Now use Spec / Size change option to modify its Size from 100 to 125&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_46_2D00_49.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_48_2D00_22.png" /&gt;&lt;/li&gt;
&lt;li&gt;Save the settings and verify the result as shown below.&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_50_2D00_08.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;All procedure of how to do it can be checked in this video:&lt;br /&gt;&lt;br /&gt;&lt;/p&gt;
&lt;h3&gt;See Also&lt;/h3&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h2&gt;Comments or Corrections?&lt;/h2&gt;
&lt;p&gt;Bentley&amp;#39;s Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Custom Length Value, OpenPlant Modeler, Change Size, Change Spec&lt;/div&gt;
</description></item><item><title>How to Leave Custom Length Value after using Change Spec / Change Size Option</title><link>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/40007/how-to-leave-custom-length-value-after-using-change-spec-change-size-option/revision/3</link><pubDate>Wed, 17 Oct 2018 09:36:12 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:59cc1f1b-365c-4f9a-88c5-f8e1c76fc0f6</guid><dc:creator>Kestutis Mitkus</dc:creator><comments>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/40007/how-to-leave-custom-length-value-after-using-change-spec-change-size-option#comments</comments><description>Revision 3 posted to OpenPlant | AutoPLANT Wiki by Kestutis Mitkus on 10/17/2018 9:36:12 AM&lt;br /&gt;
&lt;p&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;height:124px;width:500px;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Applies To&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenPlant Modeler&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.11.09.XXX (SS5) | 08.11.11.XXX (SS6)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Windows 7/8.1/10 (64 bit)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Settings/Attributes&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;-&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Kestutis Mitkus,&amp;nbsp;Bentley Product Advantage Group&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h2&gt;Overview&lt;/h2&gt;
&lt;p&gt;In OpenPlant Modeler, various options are designed to use component data from Specifications, but sometimes there are cases where there is no need to use .&amp;nbsp;&lt;/p&gt;
&lt;h3&gt;Problem Description&lt;/h3&gt;
&lt;p&gt;In OpenPlant Modeler we place Inline Piping Component and then changing its Length. When we will try to change components Size using Spec/Size change option, it will Automatically change component length to the value which is written in COMP_LEN field of specification. Such behavior is not useful for user who have modeled large Piping systems and after any size change they will be forced to go and try modify each Inline Component manually.&lt;/p&gt;
&lt;h3&gt;Steps to Resolve&lt;/h3&gt;
&lt;ol&gt;
&lt;li&gt;Launch the Bentley Class Editor and open the following schemas.&lt;br /&gt;&lt;br /&gt;OpenPlant_3D.01.07.ecschema.xml &amp;nbsp;(%ProjectRoot%...\WorkSpace\ &amp;nbsp;&amp;nbsp;&amp;nbsp;Projects\OPModeler_Metric\ DataSet\Schemas\).&lt;br /&gt;&lt;br /&gt;Supplement With,OpenPlant_3D_Supplemental_Modeling.01.07. ecschema.xml (%ProjectRoot%...\WorkSpace\Projects\OPModeler_Metric\ DataSet \ Schemas\).&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;&lt;i&gt;For More information on supplementing schema&amp;nbsp;&lt;a title="To Supplement schemas" href="/products/plant/design___engineering/w/plant_design_and_engineering__wiki/31218.to-open-schema-in-class-editor"&gt;click here&amp;gt;&amp;gt;&amp;gt;&amp;gt;&lt;/a&gt;&lt;/i&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Search for Inline Pipe Component class, select on Properties section, LENGTH property&amp;nbsp;and scroll till OpenPlant_Physical_Catalogue_Property_Map custom attribute.&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_24_2D00_56.png" /&gt;&lt;br /&gt;&lt;br /&gt;Verify, that system is always checking COMP_LEN value on specification and this is the cause of such OpenPlant behavior.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Select to Add/Remove Custom Attributes. Then in opened dialog, remove existing OpenPlant_Physical_Catalogue_Property_Map&amp;nbsp; and add Default value&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_26_2D00_03.png" /&gt;&lt;br /&gt;&lt;br /&gt;Input some standard Default value which always will be used while placing new Inline Pipe Component, but wont be used anymore while using Change Spec / Size option.&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_27_2D00_19.png" /&gt;&lt;/li&gt;
&lt;li&gt;Save &amp;amp; Close Schema.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Launch OpenPlant Modeler and place any Generic Pipe Component&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_44_2D00_03.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_45_2D00_36.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Modify its Length&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_51_2D00_16.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Now use Spec / Size change option to modify its Size from 100 to 125&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_46_2D00_49.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_48_2D00_22.png" /&gt;&lt;/li&gt;
&lt;li&gt;Save the settings and verify the result as shown below.&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_50_2D00_08.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;All procedure of how to do it can be checked in this video:&lt;br /&gt;&lt;br /&gt;&lt;a href="https://communities.bentley.com/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/SpecSizeChange.mp4"&gt;communities.bentley.com/.../SpecSizeChange.mp4&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;See Also&lt;/h3&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h2&gt;Comments or Corrections?&lt;/h2&gt;
&lt;p&gt;Bentley&amp;#39;s Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Custom Length Value, OpenPlant Modeler, Change Size, Change Spec&lt;/div&gt;
</description></item><item><title>How to Leave Custom Length Value after using Change Spec / Change Size Option</title><link>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/40007/how-to-leave-custom-length-value-after-using-change-spec-change-size-option/revision/2</link><pubDate>Wed, 17 Oct 2018 08:43:19 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:59cc1f1b-365c-4f9a-88c5-f8e1c76fc0f6</guid><dc:creator>Kestutis Mitkus</dc:creator><comments>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/40007/how-to-leave-custom-length-value-after-using-change-spec-change-size-option#comments</comments><description>Revision 2 posted to OpenPlant | AutoPLANT Wiki by Kestutis Mitkus on 10/17/2018 8:43:19 AM&lt;br /&gt;
&lt;p&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;height:124px;width:500px;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Applies To&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenPlant Modeler&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.11.09.XXX (SS5) | 08.11.11.XXX (SS6)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Windows 7/8.1/10 (64 bit)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Settings/Attributes&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;-&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Kestutis Mitkus,&amp;nbsp;Bentley Product Advantage Group&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h2&gt;Overview&lt;/h2&gt;
&lt;p&gt;In OpenPlant Modeler, various options are designed to use component data from Specifications, but sometimes there are cases where there is no need to use .&amp;nbsp;&lt;/p&gt;
&lt;h3&gt;Problem Description&lt;/h3&gt;
&lt;p&gt;In OpenPlant Modeler we place Inline Piping Component and then changing its Length. When we will try to change components Size using Spec/Size change option, it will Automatically change component length to the value which is written in COMP_LEN field of specification. Such behavior is not useful for user who have modeled large Piping systems and after any size change they will be forced to go and try modify each Inline Component manually.&lt;/p&gt;
&lt;h3&gt;Steps to Resolve&lt;/h3&gt;
&lt;ol&gt;
&lt;li&gt;Launch the Bentley Class Editor and open the following schemas.&lt;br /&gt;&lt;br /&gt;OpenPlant_3D.01.07.ecschema.xml &amp;nbsp;(%ProjectRoot%...\WorkSpace\ &amp;nbsp;&amp;nbsp;&amp;nbsp;Projects\OPModeler_Metric\ DataSet\Schemas\).&lt;br /&gt;&lt;br /&gt;Supplement With,OpenPlant_3D_Supplemental_Modeling.01.07. ecschema.xml (%ProjectRoot%...\WorkSpace\Projects\OPModeler_Metric\ DataSet \ Schemas\).&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;&lt;i&gt;For More information on supplementing schema&amp;nbsp;&lt;a title="To Supplement schemas" href="/products/plant/design___engineering/w/plant_design_and_engineering__wiki/31218.to-open-schema-in-class-editor"&gt;click here&amp;gt;&amp;gt;&amp;gt;&amp;gt;&lt;/a&gt;&lt;/i&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Search for Inline Pipe Component class, select on Properties section, LENGTH property&amp;nbsp;and scroll till OpenPlant_Physical_Catalogue_Property_Map custom attribute.&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_24_2D00_56.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Save &amp;amp; Close Schema.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Launch OpenPlant Modeler and place any Generic Pipe Component&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_44_2D00_03.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_45_2D00_36.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Modify its Length&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_51_2D00_16.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Now use Spec / Size change option to modify its Size from 100 to 125&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_46_2D00_49.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_48_2D00_22.png" /&gt;&lt;/li&gt;
&lt;li&gt;Save the settings and verify the result as shown below.&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_50_2D00_08.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;All procedure of how to do it can be checked in this video:&lt;br /&gt;&lt;br /&gt;&lt;a href="https://communities.bentley.com/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/SpecSizeChange.mp4"&gt;communities.bentley.com/.../SpecSizeChange.mp4&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;See Also&lt;/h3&gt;
&lt;p&gt;&lt;/p&gt;
&lt;h2&gt;Comments or Corrections?&lt;/h2&gt;
&lt;p&gt;Bentley&amp;#39;s Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?&amp;quot; section. THANK YOU!&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: Custom Length Value, OpenPlant Modeler, Change Size, Change Spec&lt;/div&gt;
</description></item><item><title>How to Leave Custom Length Value after using Change Spec / Change Size Option</title><link>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/40007/how-to-leave-custom-length-value-after-using-change-spec-change-size-option/revision/1</link><pubDate>Wed, 17 Oct 2018 08:41:29 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:59cc1f1b-365c-4f9a-88c5-f8e1c76fc0f6</guid><dc:creator>Kestutis Mitkus</dc:creator><comments>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/40007/how-to-leave-custom-length-value-after-using-change-spec-change-size-option#comments</comments><description>Revision 1 posted to OpenPlant | AutoPLANT Wiki by Kestutis Mitkus on 10/17/2018 8:41:29 AM&lt;br /&gt;
&lt;p&gt;&lt;b&gt;&lt;img alt=" " height="60" src="/cfs-file.ashx/__key/communityserver-components-sitefiles/TSG-Logo.png" width="189" /&gt;&lt;/b&gt;&lt;/p&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;height:124px;width:500px;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Applies To&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenPlant Modeler&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;08.11.09.XXX (SS5) | 08.11.11.XXX (SS6)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Windows 7/8.1/10 (64 bit)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Settings/Attributes&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Subarea:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;-&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td style="text-align:left;"&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Kestutis Mitkus,&amp;nbsp;Bentley Product Advantage Group&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;h2&gt;Overview&lt;/h2&gt;
&lt;p&gt;In OpenPlant Modeler, various options are designed to use component data from Specifications, but sometimes there are cases where there is no need to use .&amp;nbsp;&lt;/p&gt;
&lt;h3&gt;Problem Description&lt;/h3&gt;
&lt;p&gt;&lt;span style="font-size:12px;"&gt;In OpenPlant Modeler we place Inline Piping Component and then changing its Length. When we will try to change components Size using Spec/Size change option, it will Automatically change component length to the value which is written in COMP_LEN field of specification. Such behavior is not useful for user who have modeled large Piping systems and after any size change they will be forced to go and try modify each Inline Component manually.&lt;br /&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h3&gt;Steps to Resolve&lt;/h3&gt;
&lt;ol&gt;
&lt;li&gt;Launch the Bentley Class Editor and open the following schemas.&lt;br /&gt;&lt;br /&gt;OpenPlant_3D.01.07.ecschema.xml &amp;nbsp;(%ProjectRoot%...\WorkSpace\ &amp;nbsp;&amp;nbsp;&amp;nbsp;Projects\OPModeler_Metric\ DataSet\Schemas\).&lt;br /&gt;&lt;br /&gt;Supplement With,OpenPlant_3D_Supplemental_Modeling.01.07. ecschema.xml (%ProjectRoot%...\WorkSpace\Projects\OPModeler_Metric\ DataSet \ Schemas\).&lt;br /&gt;&lt;br /&gt;&lt;strong&gt;&lt;i&gt;For More information on supplementing schema&amp;nbsp;&lt;a title="To Supplement schemas" href="/products/plant/design___engineering/w/plant_design_and_engineering__wiki/31218.to-open-schema-in-class-editor"&gt;click here&amp;gt;&amp;gt;&amp;gt;&amp;gt;&lt;/a&gt;&lt;/i&gt;&lt;/strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;&lt;span&gt;Search for Inline Pipe Component class, select on Properties section, LENGTH property&amp;nbsp;and scroll till OpenPlant_Physical_Catalogue_Property_Map custom attribute.&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_24_2D00_56.png" /&gt;&lt;/span&gt;&lt;span&gt;&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/li&gt;
&lt;li&gt;Save &amp;amp; Close Schema.&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Launch OpenPlant Modeler and place any Generic Pipe Component&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_44_2D00_03.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_45_2D00_36.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Modify its Length&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_51_2D00_16.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Now use Spec / Size change option to modify its Size from 100 to 125&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_46_2D00_49.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_48_2D00_22.png" /&gt;&lt;/li&gt;
&lt;li&gt;Save the settings and verify the result as shown below.&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/1040x0/__key/communityserver-wikis-components-files/00-00-00-00-43/2018_2D00_10_2D00_17_5F00_9_2D00_50_2D00_08.png" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;/ol&gt;
&lt;p&gt;All procedure of how to do it can be checked in this video:&lt;br /&gt;&lt;br /&gt;&lt;a href="https://communities.bentley.com/cfs-file/__key/communityserver-wikis-components-files/00-00-00-00-43/SpecSizeChange.mp4"&gt;communities.bentley.com/.../SpecSizeChange.mp4&lt;/a&gt;&lt;/p&gt;