<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>How to Fix Generic Valve Insertion Issue in OpenPlant Modeler</title><link>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/40060/how-to-fix-generic-valve-insertion-issue-in-openplant-modeler</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>How to Fix Generic Valve Insertion Issue in OpenPlant Modeler</title><link>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/40060/how-to-fix-generic-valve-insertion-issue-in-openplant-modeler</link><pubDate>Tue, 29 Dec 2020 19:05:13 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:0c3fb7aa-ea0d-47b7-82fe-211c6498f0f7</guid><dc:creator>Aishwarya Kulkarni</dc:creator><comments>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/40060/how-to-fix-generic-valve-insertion-issue-in-openplant-modeler#comments</comments><description>Current Revision posted to OpenPlant | AutoPLANT Wiki by Aishwarya Kulkarni on 12/29/2020 7:05:13 PM&lt;br /&gt;
&lt;h1&gt;&lt;b&gt;&lt;img alt=" " src="/resized-image/__size/182x54/__key/communityserver-wikis-components-files/00-00-00-00-43/pastedimage1524216352232v1.png" /&gt;&lt;br /&gt;&lt;/b&gt;&lt;/h1&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;height:161px;width:426px;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenPlant Modeler&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;
&lt;p&gt;08.11.09.XXX (SS5) | 08.11.11.XX (SS6)&lt;/p&gt;
&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Windows 7/8.1/10 (64-bit)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenPlant Modeler&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Placement&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Deepak Singh,Bentley Product Advantage Group&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;In OpenPlant Modeler, inserting a generic valve to pipe doesn&amp;rsquo;t break the pipe &amp;amp; no connection with generic valve generates.&lt;/p&gt;
&lt;h3&gt;Background&lt;/h3&gt;
&lt;p&gt;&lt;span&gt;In OpenPlant Modeler, inserting a generic valve to pipe doesn&amp;rsquo;t break pipe &amp;amp; doesn&amp;rsquo;t generate flange connection to it. This leads to dis-connectivity&amp;nbsp;with pipe &amp;amp; placed generic valve as shown below. This wiki article explains the customization to fix this issue.&lt;br /&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="padding-left:30px;"&gt;&lt;span&gt;&lt;img alt=" " src="/resized-image/__size/650x650/__key/communityserver-wikis-components-files/00-00-00-00-43/2555.1.jpg" /&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h3&gt;&lt;span&gt;Steps to Accomplish&lt;/span&gt;&lt;/h3&gt;
&lt;ol&gt;
&lt;li&gt;&lt;span&gt;Launch &lt;strong&gt;Bentley Class Editor&lt;/strong&gt;.&lt;/span&gt;&lt;/li&gt;
&lt;li&gt;&lt;span&gt;Open &lt;strong&gt;OpenPlant_3D.&lt;/strong&gt;&lt;strong&gt;01.07. ecschema &lt;/strong&gt;of respective project from mentioned directory.&lt;br /&gt; &lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/650x650/__key/communityserver-wikis-components-files/00-00-00-00-43/xx.jpg" /&gt;&lt;br /&gt; &lt;br /&gt; &lt;/span&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt; &lt;/strong&gt;&lt;span&gt;Supplement with &lt;strong&gt;OpenPlant_3D_Supplemental_Modeling.&lt;/strong&gt;&lt;strong&gt;01.07.ecschema&lt;/strong&gt; &amp;amp; &lt;strong&gt;OpenPlant_3D_Supplemental_ModelingViews.01.07.ecschema.&lt;br /&gt; &lt;br /&gt; &lt;/strong&gt;&lt;/span&gt;&lt;em&gt;For More information on supplementing schema&amp;nbsp;&lt;/em&gt;&lt;strong&gt;&lt;em&gt;&lt;/em&gt;&lt;/strong&gt;&lt;span&gt;&lt;a href="/products/plant/w/plant_design_and_engineering__wiki/31218/to-open-schema-in-class-editor"&gt;&lt;strong&gt;&lt;em&gt;Click Here&amp;gt;&amp;gt;&amp;gt;&amp;gt;&lt;/em&gt;&lt;/strong&gt;&lt;/a&gt;&lt;/span&gt;&lt;strong&gt;&lt;br /&gt; &lt;br /&gt; &lt;/strong&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt; &lt;/strong&gt;Navigate to&lt;strong&gt; GENERIC Valve &lt;/strong&gt;class&lt;strong&gt;.&lt;/strong&gt; Refer image below.&lt;strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/650x650/__key/communityserver-wikis-components-files/00-00-00-00-43/7853.2.jpg" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/strong&gt;&lt;/li&gt;
&lt;li&gt;&lt;span&gt;From &lt;strong&gt;BaseClasses&lt;/strong&gt; of &lt;strong&gt;GENERIC_VALVE&lt;/strong&gt; click on &lt;strong&gt;ellipses&lt;/strong&gt;. Refer image below.&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/650x650/__key/communityserver-wikis-components-files/00-00-00-00-43/2821.3.jpg" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/li&gt;
&lt;li&gt;&lt;span&gt;From &lt;strong&gt;Base Classes&lt;/strong&gt; window search for &lt;strong&gt;INLINE_VALVE&lt;/strong&gt; and click on &lt;strong&gt; &lt;/strong&gt;Refer image below.&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/650x650/__key/communityserver-wikis-components-files/00-00-00-00-43/8880.4.jpg" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/li&gt;
&lt;li&gt;Select &lt;strong&gt;INLINE_VALVE&lt;/strong&gt;, using &lt;strong&gt;down arrow&lt;/strong&gt; move it to &lt;strong&gt;Added Classes&lt;/strong&gt; list &amp;amp; select &lt;strong&gt;OK&lt;/strong&gt;. Refer image below.&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/650x650/__key/communityserver-wikis-components-files/00-00-00-00-43/5684.5.jpg" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Notice that &lt;strong&gt;GENERIC_VALVE&lt;/strong&gt; class &lt;strong&gt;BaseClasses &lt;/strong&gt;list updated as shown below.&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/650x650/__key/communityserver-wikis-components-files/00-00-00-00-43/7750.6.jpg" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Save all the changes &amp;amp; verify result in OpenPlant Modeler.&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/650x650/__key/communityserver-wikis-components-files/00-00-00-00-43/0638.7.jpg" /&gt;&lt;br /&gt;&lt;br /&gt;Notice that inserting of generic valve to pipe generate connection with pipe as shown above.&lt;/li&gt;
&lt;/ol&gt;
&lt;h3&gt;See Also&lt;/h3&gt;
&lt;p&gt;&lt;a href="https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/40052/how-to-use-display-label-as-property-value-in-openplant-modeler"&gt;communities.bentley.com/.../how-to-use-display-label-as-property-value-in-openplant-modeler&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;&lt;span&gt;&lt;strong&gt;See Video&lt;/strong&gt;&lt;/span&gt;&lt;/h3&gt;
&lt;p&gt;&lt;span&gt;&lt;strong&gt;&lt;a href="https://communities.bentley.com/products/plant/m/plant_design_and_engineering_files/273414"&gt;communities.bentley.com/.../273414&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;&lt;/span&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: OpenPlant Modeler, OPM, Generic Valve Placement Fix, Migrated_v8i-CE, Generic Valve in OpenPlant Modeler, Generic Valve Placement Issue in OPM, Generic Valve Placement&lt;/div&gt;
</description></item><item><title>How to Fix Generic Valve Insertion Issue in OpenPlant Modeler</title><link>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/40060/how-to-fix-generic-valve-insertion-issue-in-openplant-modeler/revision/1</link><pubDate>Wed, 24 Oct 2018 09:32:08 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:0c3fb7aa-ea0d-47b7-82fe-211c6498f0f7</guid><dc:creator>Deepak Singh</dc:creator><comments>https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/40060/how-to-fix-generic-valve-insertion-issue-in-openplant-modeler#comments</comments><description>Revision 1 posted to OpenPlant | AutoPLANT Wiki by Deepak Singh on 10/24/2018 9:32:08 AM&lt;br /&gt;
&lt;h1&gt;&lt;b&gt;&lt;img alt=" " src="/resized-image/__size/182x54/__key/communityserver-wikis-components-files/00-00-00-00-43/pastedimage1524216352232v1.png" /&gt;&lt;br /&gt;&lt;/b&gt;&lt;/h1&gt;
&lt;table style="background-color:#dce5f0;border:0px solid #dce5f0;height:161px;width:426px;" border="0"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;&lt;b&gt;Applies To&amp;nbsp;&lt;/b&gt;&lt;/td&gt;
&lt;td&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Product(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenPlant Modeler&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Version(s):&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;
&lt;p&gt;08.11.09.XXX (SS5) | 08.11.11.XX (SS6)&lt;/p&gt;
&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Environment:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Windows 7/8.1/10 (64-bit)&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Area:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;OpenPlant Modeler&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Subarea:&amp;nbsp;&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Placement&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
&lt;td&gt;&lt;strong&gt;Original Author:&lt;/strong&gt;&lt;/td&gt;
&lt;td&gt;Deepak Singh,Bentley Product Advantage Group&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;In OpenPlant Modeler, inserting a generic valve to pipe doesn&amp;rsquo;t break the pipe &amp;amp; no connection with generic valve generates.&lt;/p&gt;
&lt;h3&gt;Background&lt;/h3&gt;
&lt;p&gt;&lt;span&gt;In OpenPlant Modeler, inserting a generic valve to pipe doesn&amp;rsquo;t break pipe &amp;amp; doesn&amp;rsquo;t generate flange connection to it. This leads to dis-connectivity&amp;nbsp;with pipe &amp;amp; placed generic valve as shown below. This wiki article explains the customization to fix this issue.&lt;br /&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style="padding-left:30px;"&gt;&lt;span&gt;&lt;img alt=" " src="/resized-image/__size/650x650/__key/communityserver-wikis-components-files/00-00-00-00-43/2555.1.jpg" /&gt;&lt;/span&gt;&lt;/p&gt;
&lt;h3&gt;&lt;span&gt;Steps to Accomplish&lt;/span&gt;&lt;/h3&gt;
&lt;ol&gt;
&lt;li&gt;&lt;span&gt;Launch &lt;strong&gt;Bentley Class Editor&lt;/strong&gt;.&lt;/span&gt;&lt;/li&gt;
&lt;li&gt;&lt;span&gt;Open &lt;strong&gt;OpenPlant_3D.&lt;/strong&gt;&lt;strong&gt;01.07. ecschema &lt;/strong&gt;of respective project from mentioned directory.&lt;br /&gt; &lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/650x650/__key/communityserver-wikis-components-files/00-00-00-00-43/xx.jpg" /&gt;&lt;br /&gt; &lt;br /&gt; &lt;/span&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt; &lt;/strong&gt;&lt;span&gt;Supplement with &lt;strong&gt;OpenPlant_3D_Supplemental_Modeling.&lt;/strong&gt;&lt;strong&gt;01.07.ecschema&lt;/strong&gt; &amp;amp; &lt;strong&gt;OpenPlant_3D_Supplemental_ModelingViews.01.07.ecschema.&lt;br /&gt; &lt;br /&gt; &lt;/strong&gt;&lt;/span&gt;&lt;em&gt;For More information on supplementing schema&amp;nbsp;&lt;/em&gt;&lt;strong&gt;&lt;em&gt;&lt;/em&gt;&lt;/strong&gt;&lt;span&gt;&lt;a href="/products/plant/w/plant_design_and_engineering__wiki/31218/to-open-schema-in-class-editor"&gt;&lt;strong&gt;&lt;em&gt;Click Here&amp;gt;&amp;gt;&amp;gt;&amp;gt;&lt;/em&gt;&lt;/strong&gt;&lt;/a&gt;&lt;/span&gt;&lt;strong&gt;&lt;br /&gt; &lt;br /&gt; &lt;/strong&gt;&lt;/li&gt;
&lt;li&gt;&lt;strong&gt; &lt;/strong&gt;Navigate to&lt;strong&gt; GENERIC Valve &lt;/strong&gt;class&lt;strong&gt;.&lt;/strong&gt; Refer image below.&lt;strong&gt;&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/650x650/__key/communityserver-wikis-components-files/00-00-00-00-43/7853.2.jpg" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/strong&gt;&lt;/li&gt;
&lt;li&gt;&lt;span&gt;From &lt;strong&gt;BaseClasses&lt;/strong&gt; of &lt;strong&gt;GENERIC_VALVE&lt;/strong&gt; click on &lt;strong&gt;ellipses&lt;/strong&gt;. Refer image below.&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/650x650/__key/communityserver-wikis-components-files/00-00-00-00-43/2821.3.jpg" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/li&gt;
&lt;li&gt;&lt;span&gt;From &lt;strong&gt;Base Classes&lt;/strong&gt; window search for &lt;strong&gt;INLINE_VALVE&lt;/strong&gt; and click on &lt;strong&gt; &lt;/strong&gt;Refer image below.&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/650x650/__key/communityserver-wikis-components-files/00-00-00-00-43/8880.4.jpg" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/span&gt;&lt;/li&gt;
&lt;li&gt;Select &lt;strong&gt;INLINE_VALVE&lt;/strong&gt;, using &lt;strong&gt;down arrow&lt;/strong&gt; move it to &lt;strong&gt;Added Classes&lt;/strong&gt; list &amp;amp; select &lt;strong&gt;OK&lt;/strong&gt;. Refer image below.&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/650x650/__key/communityserver-wikis-components-files/00-00-00-00-43/5684.5.jpg" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Notice that &lt;strong&gt;GENERIC_VALVE&lt;/strong&gt; class &lt;strong&gt;BaseClasses &lt;/strong&gt;list updated as shown below.&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/650x650/__key/communityserver-wikis-components-files/00-00-00-00-43/7750.6.jpg" /&gt;&lt;br /&gt;&lt;br /&gt;&lt;/li&gt;
&lt;li&gt;Save all the changes &amp;amp; verify result in OpenPlant Modeler.&lt;br /&gt;&lt;br /&gt;&lt;img alt=" " src="/resized-image/__size/650x650/__key/communityserver-wikis-components-files/00-00-00-00-43/0638.7.jpg" /&gt;&lt;br /&gt;&lt;br /&gt;Notice that inserting of generic valve to pipe generate connection with pipe as shown above.&lt;/li&gt;
&lt;/ol&gt;
&lt;h3&gt;See Also&lt;/h3&gt;
&lt;p&gt;&lt;a href="https://communities.bentley.com/products/plant/w/plant_design_and_engineering__wiki/40052/how-to-use-display-label-as-property-value-in-openplant-modeler"&gt;communities.bentley.com/.../how-to-use-display-label-as-property-value-in-openplant-modeler&lt;/a&gt;&lt;/p&gt;
&lt;h3&gt;&lt;span&gt;&lt;strong&gt;See Video&lt;/strong&gt;&lt;/span&gt;&lt;/h3&gt;
&lt;p&gt;&lt;span&gt;&lt;strong&gt;&lt;a href="https://communities.bentley.com/products/plant/m/plant_design_and_engineering_files/273414"&gt;communities.bentley.com/.../273414&lt;/a&gt;&lt;/strong&gt;&lt;/span&gt;&lt;span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;span&gt;&lt;/span&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: OpenPlant Modeler, OPM, Generic Valve Placement Fix, Generic Valve in OpenPlant Modeler, Generic Valve Placement Issue in OPM, Generic Valve Placement&lt;/div&gt;