Bentley Communities
Site
Search
User
Site
Search
User
Product Communities
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki
Resolved issues in Bentley Raceway and Cable Management CONNECT Edition, 10.00.00.127
Sign In
-
OpenPlant | AutoPLANT Wiki
+
OpenPlant
+
Bentley AutoPLANT
+
Bentley Navigator
+
Bentley PlantSpace
+
Plant Project Tools
-
Bentley Raceway and Cable Management
How to Download Bentley Raceway and Cable Management
Bentley Raceway and Cable Management Product Compatibility
-
CONNECT Edition - Bentley Raceway and Cable Management
-
Resolved issues in Bentley Raceway and Cable Management Releases
Resolved issues in Bentley Raceway and Cable Management CONNECT Update 1, 10.01.00.21
Resolved Issues in Bentley Raceway and Cable Management CONNECT Update 2 (10.02.00.25)
Resolved Issues in Bentley Raceway and Cable Management CONNECT Update 3 (10.03.00.25)
Resolved Issues in Bentley Raceway and Cable Management CONNECT Update 4 (10.04.00.31)
Resolved Issues in Bentley Raceway and Cable Management CONNECT Update 5 (10.05.00.54)
Resolved Issues in Bentley Raceway and Cable Management CONNECT Update 9 (10.09.00.74)
Resolved issues in Bentley Raceway and Cable Management CONNECT Update 9 (10.09.01.18)
Resolved issues in Bentley Raceway and Cable Management CONNECT Edition, 10.00.00.127
Resolved issues in Bentley Raceway and Cable Management CONNECT Update 10 (10.10.00.71)
Resolved issues in Bentley Raceway and Cable Management CONNECT Update 11 (10.11.00.222)
Resolved Issues in Bentley Raceway and Cable Management CONNECT Update 11 (10.11.01.144)
+
What's New in Bentley Raceway and Cable Management Releases
+
Manufacturer Based Raceway Content in Bentley Raceway and Cable Management
+
AutoPlace Conduit tool - BRCM CONNECT Edition
+
Cable Reports- Cable Pull Cards and Cable Drums-Bentley Raceway and Cable Management CONNECT Edition
+
Cable Routing-Bentley Raceway and Cable Management CONNECT Edition.
+
Drawing generation - Bentley Raceway and Cable Management CONNECT Edition
+
i-Model - Bentley Raceway and Cable Management CONNECT Edition
+
Installation_Configuration - BRCM CONNECT
+
Power Platform Support - BRCM CONNECT Edition
+
Project Setup- Bentley Raceway and Cable Management
+
ProjectWise Integration - Bentley Raceway and Cable Management CONNECT
+
Raceway Design Tools - Bentley Raceway & Cable Management
+
Raceway IDs - Bentley Raceway and Cable Management CONNECT
+
Reports - Output Manager - BRCM CONNECT Edition
+
Underground System - Bentley Raceway and Cable Management CONNECT Edition
+
User Defined Attributes (UDA) Settings - Bentley Raceway and Cable Management CONNECT Edition
+
Components Center - Bentley Raceway and Cable Management CONNECT Edition
+
i-Twin Services-Bentley Raceway and Cable Management CONNECT Edition.
+
Equipment & Cable List Import-Bentley Raceway and Cable Management CONNECT.
+
Interoperability
BRCM Update 11 To Save Database in PlantSight
How to Change Default Categories Order in Element Information Dialog in OPPID CE
How to Change the Color of the Raceway's Level
How To Configure BRCM Raceway Labels
How To Place Parametric Supports on Raceways
How to Publish iModels in BRCM
How To Route BRCM Concrete Trench
To Import an iModel in BRCM Update 11
To Resolve Finding and Deleting Hidden Cable Trays not visible in dgn and nor can be found via selection tools in BRCM
To Resolve Review Differences dialog not showing for iModel Import workflow
+
V8i - Bentley Raceway and Cable Management
i-model Composition Service for S3D
Working from home with OpenPlant
Working from home with Bentley Raceway and Cable Management
Working from home with AutoPLANT Modeler
Your Feedback is important to us!
Learning Content for OpenPlant
Questions about this article, topic, or product? Click here.
Resolved issues in Bentley Raceway and Cable Management CONNECT Edition, 10.00.00.127
Product:
Bentley Raceway and Cable Management
Generation:
CONNECT Edition
Version:
10.00.00.127
Defect Number
Description
911638
The software crashes when double clicking a routing line to navigate to a raceway dng file when integrated with ProjectWise.
911640
The software crashed when using the navigate tool to navigate to a raceway/equipment dng file when integrated with ProjectWise.
921419
In a particular project, selecting any routed cable would result in an unhandled exception error.
909146
An unhandled exception error would occur if you tried to delete a voltage level item in the Options>Raceway Specifications>Raceway Categories dialog.
151961
Corrected a message box displayed when previewing or exporting a report that stated, "Cable Manager Loading data…" The message now properly refers to the "Output Manager" instead of the "Cable Manager."
759383
When placing a manhole using the Equipment Manager, the measured inside height should match the specified Inside Height and the measured outside height should equal Inside Height + 2 x Wall Depth.
741451
When inserting a raceway bend and connecting it to a straight the raceway guid value of the bend would become duplicated with that of the straight piece rather than being assigned an unique value.
889496
The Detail_Cable_Route_List report when run on a particular project reported all lengths as 2.0 and did not include the raceway IDs in the RW Segment ID column.
910158
Fixed the incorrect Reducer Lengths for the Cooper Cable Ladder Series 2,3,4 & 5 Steel catalog
633478
The performance of various operations in the Cable Manager have been improved which include, loading data, Auto Connect, loading Routing Manager, closing Routing Manager, Save to Project Model, Refresh Routing Model, and reopening the Cable Manager after routing is performed.
361450
Repeated raceway part creation would continually increase the memory usage until the software would crash.
652968
Publish_i-model could not create relationships between cables and other elements in the demo project BRCM_PLANT_US_COMP.
709750
The BRCM Tools > Display Manager dialog had labels that could not be localized in other languages.
614827
iModel publishing failed for a particular project.
492213
Executing 'Reroute Cables with lower Priority’ in the Routing Manager multiple times will produce an error or crash BRCM when you attempt to exit the Routing Manager.
902505
The Conceptual Design BOQ report is empty and the Length in the Conceptual_Cable_Schedules is zero when using the Conceptual Design Sample project.
637262
Updates to raceway IDs were not reflected in the Cable Manager and outputs unless you performed a new automatic routing which is not always desirable.
867859
Raceway that does not match the Context ID in the LIB_Raceway.xml was appearing by default in the Raceway Router or Duct Bank Router dialogs by mistake.
374441
The Tee fitting for the Generic Cable Tray Square raceway should not have a radius.
289520
When selecting Refresh Routing Model a status box was displayed which remained on the top of all other application windows. The status box should not be displayed on top of other unrelated applications so that it doesn't impede users from working in other applications while they wait for the command to finish.
656736
After Duct bank is copied, the ID cannot be modified and the duct bank cannot be stretched.
374242
In certain scenarios the Duct Bank Router > Connect command when using the branch option is unable to insert parts such as elbows on the selected conduits.
626673
Unable to add new raceway specs in Conceptual design.
947068
In the Raceway Catalog Creation dialog, an error appeared when adding a raceway size and pressing Enter.
947520
The Raceway Offset tool could crash the software when selecting a MV voltage level in the Raceway Properties grid.
947577
In the Raceway Router dialog, double clicking on Dividers and then setting focus to the Voltage Level cell could cause the software to crash.
816269
In the Chinese build, the software cannot generate 3D Cable visualization after importing the database xml files.
378258
Using the Raceway Catalog Creation tool to define fittings could result in incorrect chamfer and end straight lengths on vertical bend fittings.
903656
The 2D Extraction raceway labels were displaying the wrong weight and height values such as 3 instead of 300mm.
709747
Some labels in the Create New Raceway Catalog were not localizable in other languages.
867855
The Add, Copy, Paste & Delete buttons in the Equipment Manager were disabled in the Chinese localized build.
867901
If you attempted to create new equipment using a template and then tried to edit Equipment Properties an error occurred and the equipment was not created.
390666
When routing raceway and inserting a cross over fitting the variants list ends up with duplicate entries in it.
722422
The Excel import and i-model import for cable lists result in an exception error regarding missed resources.
665853
When using the Validate Active Dataset command and no error was found an awkwardly worded message was displayed.
344768
An "Incompatible item type libraries" message was displayed when publishing an i-model.
874904
Selecting multiple objects and right clicking DisplaySet clears the selection set rather than executing the command.
921096
The software crashed when updating the existing 2D section 3 in the example project BRCM_PLANT_US_Comp.
639120
The path to the EC schema files such as ECClasses.xml was hard coded, but should be configurable.
569741
The Trade width for raceway tees ($TT) does not work correctly in descriptions on reports.
562104
There are the wrong fittings defined in catalog 'Rico Wide Span Cable Ladder System 150'. All bends, tees, crossovers have to be round and not square, as well as defined in 'Rico Wide Span Cable Ladder System 200' for example.
423891
When integrated with ProjectWise and you attempted to use the Output Manager to export a report you were prompted two times to specify the ProjectWise Path for the report and it did not default to the correct path. The software should now present a dialog to save the file in the folder specified by the BRCM_PW_SUBFOLDER_REPORTS variable first. If the user selects Cancel, then a dialog to save in the local file system is presented.
179736
Schedule 80 conduits don't have correct body style Tee fitting.
CONNECT Edition
connect
en
bentley raceway and cable management
Resolved Issues
10.00.00.127
Share
History
More
Cancel
Created by
Scott Walker
When:
Mon, Nov 26 2018 3:50 PM
Last revision by
Scott Walker
When:
Tue, Jan 9 2024 12:56 PM
Revisions:
3
Comments:
0
Recommended
Related