Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
OpenPlant | AutoPLANT
  • Product Communities
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki Description for Bolts, Gaskets In Isometric BOM Showing as "NODESC"
    • Sign In
    • -OpenPlant | AutoPLANT Wiki
      • -OpenPlant
        • +CONNECT Services - OpenPlant
        • +Example Configuration - CONNECT Edition
        • +Installations - OpenPlant CONNECT Edition Applications
        • +OpenPlant Download Links & Videos
        • OpenPlant Product Compatibility
        • +OpenPlant Modeler CONNECT
        • +OpenPlant PID CONNECT
        • +OpenPlant Isometrics Manager CONNECT
        • +OpenPlant Orthographics Manager CONNECT
        • +OpenPlant Support Engineering CONNECT
        • +OpenPlant Project Administrator CONNECT
        • +OpenPlant CONNECT Edition-PlantSight Integration
        • +OpenPlant Modeler v8i
        • -OpenPlant Isometrics Manager v8i
          • +OpenPlant Isometrics Manager for OpenPlant
          • -OpenPlant Isometrics Manager for AutoPLANT
            • Installation/Upgradation Steps of OpenPlant Isometrics Manager for AutoPLANT
            • -Errors, Logs, Messages, Crashes - OpenPlant Isometrics Manager for AutoPLANT
              • Description for Bolts, Gaskets In Isometric BOM Showing as "NODESC"
              • Element ‘VALVE_HAS_VALVE_OPERATING _DEVICE’ is missing required attribute ‘sourceClass’
              • Error: Mapping of component not found, Class Name: BASE_AT_LUG_W_BOLT
              • Error: Mapping of component not found, Class Name: AT_PVIC_AT_SOCKETWELD
              • Error: The Process cannot Access the File in OpenPlant Isometrics Manager
              • Error: Scaler, Symbols or Item code are missing for TAP_CONNECTION when Branch Connected Through Stub-In Tapport
              • Error: XCHG0000: Failed to initialize OpenPlant Isometric data converter 1
              • Error: XCHG0000: Invalid Translation Format: OPIM in OpenPlant Isometrics Manager
              • Error[0]: Unable to locate ADDON (ID=XXX) to DCP
              • Error[0]: Unable to Locate ADDON (4) to DCP when Miscellaneous Attachment on Pipe
              • Error[5]Cell not found in libraries: GATSW_FT
              • Error[5] Unable to Place Symbol: FLNWNF, PGKT, GATFL When Use Custom Seed File (Backing Sheet)
              • ERROR[5]: DWG creation failed while Generating Isometric Output as DWG Format
              • To Avoid Crash for End Types WFL & Butt Weld Connections in Isometrics
              • Isometric successfully, but PCF generation failed Message in OpenPlant Isometrics Manager
              • Unresolved References Files Error on Opening DWG Isometric in AutoCAD
              • Check Internet Connection and Restart the Setup or Provide Proxy Settings
              • References-Unresolved Reference file error while opening DWG format Isometric drawing in AutoCAD
              • The Specified module could not be found (Exception from HRESULT: 0X8007007E)
            • +Open/Save - OpenPlant Isometrics Manager for AutoPLANT
            • +Processing - OpenPlant Isometrics Manager for AutoPLANT
            • +Settings/Attributes - OpenPlant Isometrics Manager for AutoPLANT
            • How to Create Special Stamps using Detail Sketches in OpenPlant Isometrics Manager in CONNECT Edition
            • How to Create Special Stamps using Reports in OpenPlant Isometrics Manager in CONNECT Edition
            • How to Delete Ecxml Files, after certain Period in CONNECT Edition
            • How to Export Bill of Material In CSV Excel Format for AutoPLANT Modeler in CONNECT Edition
            • How to Publish Isometrics in DGN, DWG and PDF Output Formats in CONNECT Edition
            • How to Save Isometrics Output on Network Drive for AutoPLANT in CONNECT Edition
          • +Release Notes - OpenPlant Isometrics Manager
          • OpenPlant Isometrics Manager [FAQ]
        • +OpenPlant Project Administrator v8i
        • +OpenPlant PID v8i
        • +OpenPlant Orthographics Manager v8i
        • +OpenPlant Support Engineering v8i
        • +OpenPlant ModelServer v8i
        • +OpenPlant Reporting v8i
        • How to Connect with Bentley Technical Support Team using Microsoft Teams
        • How to Connect with Bentley Technical Support Team using Microsoft Teams via Browser
        • How to get list of installed applications/programs on Windows Machine using Command Prompt.
        • How to get list of Windows Updates installed on the machine using Command Prompt.
        • How to Package WorkSpace to be Shareable to Users for OpenPlant Projects
      • +Bentley AutoPLANT
      • +Bentley Navigator
      • +Bentley PlantSpace
      • +Plant Project Tools
      • +Bentley Raceway and Cable Management
      • i-model Composition Service for S3D
      • Working from home with OpenPlant
      • Working from home with Bentley Raceway and Cable Management
      • Working from home with AutoPLANT Modeler
      • Your Feedback is important to us!

     
     Questions about this article, topic, or product? Click here. 

    Description for Bolts, Gaskets In Isometric BOM Showing as "NODESC"

    Applies To
    Product(s): OpenPlant Isometrics Manager
    Version(s): 08.11.09.574 (SS5)
    Environment: Windows 7/8.1/10 (64 bit)
    Area: Settings/Attributes
    Subarea: BOM Description
    Original Author: Abhijit Bute, Bentley Product Advantage Group

    In Latest OpenPlant Isometrics Manager version this issue is already fixed.

    Problem Description

    During isometric generation of OpenPlant Isometrics Manager, Description for gasket and bolts are not getting updated in isometric.It shows as 'NODESC'. See image below.

    This issue is already fixed in latest OpenPlant Isometrics Manager.

    Steps to Resolve

    1. Open Bentley Class Editor
    2. Open "OpenPlant_3D.01.06 schema". See Image below. 


      Note - Navigate to working project path as shown below.
      (C:\ProgramData\Bentley\Plant V8i\Bentley Plant V8i Projects\SAMPLE_IMPERIAL\Config\OpenPlant\schemas)

    3. Right click on "OpenPlant_3D.01.06 schema" &S click on supplement Schema option. 


    4. Using "Add" button, select Supplemental schema "OpenPlant_3D_Supplemental_Isometrics_Isoextractor.01.06 schema" and click on "Open". See image below. 


    5. (Optional If dialog appears) Click on "Open" for allowing to select Missing reference schema folder. See image below on how to navigate the correct folder path. User may cancel to load other available reference schema. 

      Note - Path to check - (C:\ProgramData\Bentley\Plant V8i\Bentley Plant V8i Projects\SAMPLE_IMPERIAL\Config\OpenPlant\schemas)

    6. Search/Navigate to GASKET class as shown in below image.


    7. Highlight Gasket on the left and go to the "Properties" tab on the right and highlight DESCRIPTION property.
    8. Click on  Add/Remove Custom attributes. See image below.


    9. Find the "AutoPLANT_PDW_Property_Map", highlight it and pull it down to add it in. Click "OK".


    10. Under the "AutoPLANT 3D" custom attribute, add LONG_DESC in the Property Name field. See image below.


    11. Navigate to BOLT class.
    12. Repeat Step 9 & 10 under Bolt Property tab.
    13. Save and close Schema.
    14. Restart AutoPLANT Modeler and review the result.


    15. Also perform the above steps in the schemas for other projects
      C:\Program Files (x86)\Bentley\Plant V8i\Config\Metric\OpenPlant\schemas
      C:\Program Files (x86)\Bentley\Plant V8i\Config\Mmetric\OpenPlant\schemas
      C:\Program Files (x86)\Bentley\Plant V8i\Config\Imperial\OpenPlant\schemas

    16. This ensures that new created project also has the descriptions. 

    Still a Problem?

    If above problem still persist, then please create a Service Request and contact the Bentley Product Advantage group. Please include a list of all relevant details to get in depth analysis for a solution or workaround. 

    See Also

    Errors, Logs, Messages, Crashes - OpenPlant Isometrics Manager for AutoPLANT
    Processing - OpenPlant Isometrics Manager To Discuss content related to Errors, Logs, Messages, Crashes in OpenPlant Isometrics Manager for AutoPLANT. Isometrics generation Errors/ Reading Logs/Message…
    Last edited over 3 years ago in OpenPlant | AutoPLANT > OpenPlant | AutoPLANT Wiki

    • AutoPLANT Modeler
    • OPIM
    • BOM
    • NODESC
    • OpenPlant Isometrics Manager
    • Share
    • History
    • More
    • Cancel
    • Kestutis Mitkus Created by Bentley Colleague Kestutis Mitkus
    • When: Wed, Dec 5 2018 6:39 AM
    • Kestutis Mitkus Last revision by Bentley Colleague Kestutis Mitkus
    • When: Fri, Dec 21 2018 7:33 AM
    • Revisions: 7
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies