Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
OpenPlant | AutoPLANT
  • Product Communities
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki ERROR[5]: DWG creation failed while Generating Isometric Output as DWG Format
    • Sign In
    • -OpenPlant | AutoPLANT Wiki
      • -OpenPlant
        • +CONNECT Services - OpenPlant
        • +Example Configuration - CONNECT Edition
        • +Installations - OpenPlant CONNECT Edition Applications
        • +OpenPlant Download Links & Videos
        • OpenPlant Product Compatibility
        • +OpenPlant Modeler CONNECT
        • +OpenPlant PID CONNECT
        • +OpenPlant Isometrics Manager CONNECT
        • +OpenPlant Orthographics Manager CONNECT
        • +OpenPlant Support Engineering CONNECT
        • +OpenPlant Project Administrator CONNECT
        • +OpenPlant CONNECT Edition-PlantSight Integration
        • +OpenPlant Modeler v8i
        • -OpenPlant Isometrics Manager v8i
          • +OpenPlant Isometrics Manager for OpenPlant
          • -OpenPlant Isometrics Manager for AutoPLANT
            • Installation/Upgradation Steps of OpenPlant Isometrics Manager for AutoPLANT
            • -Errors, Logs, Messages, Crashes - OpenPlant Isometrics Manager for AutoPLANT
              • Description for Bolts, Gaskets In Isometric BOM Showing as "NODESC"
              • Element ‘VALVE_HAS_VALVE_OPERATING _DEVICE’ is missing required attribute ‘sourceClass’
              • Error: Mapping of component not found, Class Name: BASE_AT_LUG_W_BOLT
              • Error: Mapping of component not found, Class Name: AT_PVIC_AT_SOCKETWELD
              • Error: The Process cannot Access the File in OpenPlant Isometrics Manager
              • Error: Scaler, Symbols or Item code are missing for TAP_CONNECTION when Branch Connected Through Stub-In Tapport
              • Error: XCHG0000: Failed to initialize OpenPlant Isometric data converter 1
              • Error: XCHG0000: Invalid Translation Format: OPIM in OpenPlant Isometrics Manager
              • Error[0]: Unable to locate ADDON (ID=XXX) to DCP
              • Error[0]: Unable to Locate ADDON (4) to DCP when Miscellaneous Attachment on Pipe
              • Error[5]Cell not found in libraries: GATSW_FT
              • Error[5] Unable to Place Symbol: FLNWNF, PGKT, GATFL When Use Custom Seed File (Backing Sheet)
              • ERROR[5]: DWG creation failed while Generating Isometric Output as DWG Format
              • To Avoid Crash for End Types WFL & Butt Weld Connections in Isometrics
              • Isometric successfully, but PCF generation failed Message in OpenPlant Isometrics Manager
              • Unresolved References Files Error on Opening DWG Isometric in AutoCAD
              • Check Internet Connection and Restart the Setup or Provide Proxy Settings
              • References-Unresolved Reference file error while opening DWG format Isometric drawing in AutoCAD
              • The Specified module could not be found (Exception from HRESULT: 0X8007007E)
            • +Open/Save - OpenPlant Isometrics Manager for AutoPLANT
            • +Processing - OpenPlant Isometrics Manager for AutoPLANT
            • +Settings/Attributes - OpenPlant Isometrics Manager for AutoPLANT
            • How to Change Miscellaneous Attachment Annotation Container in CONNECT Edition
            • How to Create Special Stamps using Detail Sketches in OpenPlant Isometrics Manager in CONNECT Edition
            • How to Create Special Stamps using Reports in OpenPlant Isometrics Manager in CONNECT Edition
            • How to Delete Ecxml Files, after certain Period in CONNECT Edition
            • How to Export Bill of Material In CSV Excel Format for AutoPLANT Modeler in CONNECT Edition
            • How to Publish Isometrics in DGN, DWG and PDF Output Formats in CONNECT Edition
            • How to Save Isometrics Output on Network Drive for AutoPLANT in CONNECT Edition
          • +Release Notes - OpenPlant Isometrics Manager
          • OpenPlant Isometrics Manager [FAQ]
        • +OpenPlant Project Administrator v8i
        • +OpenPlant PID v8i
        • +OpenPlant Orthographics Manager v8i
        • +OpenPlant Support Engineering v8i
        • +OpenPlant ModelServer v8i
        • +OpenPlant Reporting v8i
        • How to Connect with Bentley Technical Support Team using Microsoft Teams
        • How to Connect with Bentley Technical Support Team using Microsoft Teams via Browser
        • How to get list of installed applications/programs on Windows Machine using Command Prompt.
        • How to get list of Windows Updates installed on the machine using Command Prompt.
        • How to Package WorkSpace to be Shareable to Users for OpenPlant Projects
      • +Bentley AutoPLANT
      • +Bentley Navigator
      • +Bentley PlantSpace
      • +Plant Project Tools
      • +Bentley Raceway and Cable Management
      • i-model Composition Service for S3D
      • Working from home with OpenPlant
      • Working from home with Bentley Raceway and Cable Management
      • Working from home with AutoPLANT Modeler
      • Your Feedback is important to us!

     
     Questions about this article, topic, or product? Click here. 

    ERROR[5]: DWG creation failed while Generating Isometric Output as DWG Format

    Applies To 
    Product(s): OpenPlant Isometrics Manager
    Version(s): till 08.11.11.294 (SS6)
    Environment:  Windows 7/8.1/10 (64 bit)
    Area:  Settings/Attributes
    Subarea:  Isometric Configuration
    Original Author: Rahul Kumar, Bentley Product Advantage Group

    Overview

    In Latest OpenPlant Isometrics Manager version this issue is already fixed

    In OpenPlant Isometrics Manager, during isometrics generation it displays error as ERROR[5]: DWG creation failed.

    Problem Description

    In OpenPlant Isometrics Manager, when “Isometric Output Format” option selected as DWG like shown in below image.

              

    When user generates an isometrics then following error prompts as shown below. 

              

    Error:ERROR[5]: DWG creation failed
                                     at Bentley.Isometrics.IsoExtWrapper.GenerateIsometrics.Execute()
       at Bentley.Isometrics.IsoProduction.PipeGenerateIso.Process(IsometricInstance isoInst)
       at Bentley.Isometrics.IsoProduction.ProcessingPipes.ProcessIsoInstance(BackgroundWorker bWorker, IsometricInstance isoInst, Boolean& success)

              

    Below steps will aid user to avoid such errors. Below example and error caused shown here using OpenPlant Modeler and OpenPlant Isometrics Manager. However similar instances might occur using AutoPLANT modeler and OpenPlant Isometrics Manager.

    Steps to Resolve

    Case1

    1. The above errors mentioned due to missing file present inside the “dwgdata“ folder which is found under each styles for isometrics. See image below. 



    2. User has to check file defined inside the OpenPlant Modeler. See default dwgdata folder below where all files are present. 



    3. Update the missing file to working style folder under “dwgdata” folder & verify results. See below image after putting all relevant files. 


    Case2

    In some cases OpenPlant Isometrics Manager not installed properly or by mistake some files get deleted from following location.
    C:\Program Files (x86)\Common Files\Bentley Shared\RealDWG2016

    1. Go to following location.   
      C:\BentleyDownloads\OpenPlantIsometricsManager_08.11.11.294

    2.  Run RealDwg2016.msi file.
       
        

    Still a Problem?

    If above problem still persist, then please create a Service Request and contact the Bentley Product Advantage group.  Please include a list of all relevant details to get in depth analysis for a solution or workaround. 

    See Also

    Errors, Logs, Messages, Crashes - OpenPlant Isometrics Manager for AutoPLANT
    Processing - OpenPlant Isometrics Manager To Discuss content related to Errors, Logs, Messages, Crashes in OpenPlant Isometrics Manager for AutoPLANT. Isometrics generation Errors/ Reading Logs/Message…
    Last edited over 3 years ago in OpenPlant | AutoPLANT > OpenPlant | AutoPLANT Wiki

    Comments or Corrections?

    Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

    • AutoPLANT Modeler
    • OPIM
    • Isometric Output
    • DWG
    • DWG creation failed
    • OpenPlant Isometrics Manager
    • DWG Format
    • Share
    • History
    • More
    • Cancel
    • Kestutis Mitkus Created by Bentley Colleague Kestutis Mitkus
    • When: Wed, Dec 12 2018 10:20 AM
    • Abhijit Bute Last revision by Abhijit Bute
    • When: Tue, Mar 26 2019 10:01 AM
    • Revisions: 5
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies